TYPE L PLUS

                      

      Operating Instructions 

 

 

2.0 

Safety Notes 

 
The Type L Plus current clamp meter has left the factory in a 
perfectly  safe  state.  To  maintain  this  state  and  ensure  safe 
operation  of  the  unit,  all  notes  and  warnings  in  these 
instructions must be observed at all times. 

 

The Type L Plus current clamp meter may be safely 

applied to un-insulated conductors up to 600volts, 

provided  all  necessary  care  is  taken  to  avoid  the 

operator’s  body  or  hands  moving  in  dangerous 

proximity with the conductor. 

 

 

The  Type  L  Plus  current  clamp  meter  must  be 

checked for signs of damage before the equipment 

is operated. 

 

Where safe operation of the Type L Plus current clamp meter is 
no  longer  possible  it  should  be  immediately  shutdown  and 
secured to prevent accidental operation. 
 
It must be assumed that safe operation is no longer possible:  

- if the Type L Plus shows visible signs of damage, or 
-  the Type L Plus does not function, or 

- after long periods of storage under adverse 

environmental conditions. 

Содержание TYPE L PLUS

Страница 1: ...urrent Clamp Meter Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW England Tel 44 0 191 586 3511 Fax 44 0 191 586 0227 www seaward co uk sales seaward co uk...

Страница 2: ...lectronically mechanically by photocopying recording or in any manner without prior written consent from SEAWARD Electronic Limited This also applies to accompanying drawings and diagrams Due to a pol...

Страница 3: ...duct it means the product is covered by the European Directive 2002 96 EC Please familiarise yourself with the appropriate local separate collection system for electrical and electronic products Pleas...

Страница 4: ...ical protection Contents 1 User Notes 2 Safety Notes 3 Description 4 Electrical Specifications 5 Operation 6 Battery Installation and Replacement 7 Maintenance 8 Cleaning 1 0 User Notes These operatin...

Страница 5: ...ssary care is taken to avoid the operator s body or hands moving in dangerous proximity with the conductor The Type L Plus current clamp meter must be checked for signs of damage before the equipment...

Страница 6: ...n a 3 5 LCD display module with 12mm high characters 3 5 Three fully sealed membrane type tactile response pushbuttons allow an operator to switch the Type L Plus Off and select between Store optional...

Страница 7: ...n the battery within the unit must be replaced see section 6 5 1 2 Operate the trigger mechanism on the Type L Plus handle to pivot open the jaws of the instrument and insert the conductor to be teste...

Страница 8: ...wing through the conductor for a period of 1 to 2 seconds No current readings will be recorded for short term transient variations If the battery symbol is visible on the LCD display then the current...

Страница 9: ...The body of the Type L Plus should be regularly inspected to ensure no deep scratches or physical damage 7 4 If any of the above conditions have been observed then the Type L Plus must be appropriate...

Страница 10: ...275A550 Rev 2...

Отзывы: