Seav WiWeather Series Скачать руководство пользователя страница 2

3)

WIND 

(Wind Sensor ON/OFF)

Deactivation of the Wind Sensor 

The device is supplied with the Wind Sensor enabled (WIND 
ON LED).
The deactivation of the Wind Sensor can be carried out as fol-
lows: with the SEL key position yourself on the flashing of the 
WIND LED and press the SET key for an instant: at the same 
time, the WIND LED will switch off and the Wind Sensor deac-
tivation will be complete. It is possible to repeat the operation 
to activate the Wind Sensor.

4)

SUN 

(Sun Sensor ON/OFF)

Enabling the Sun Sensor 

The   device   is   supplied   with   the   Sun   Sensor   disabled   (SUN 
OFF LED).
The enabling of the Sun Sensor can be carried out as follows: 
with the SEL key position yourself on the flashing of the SUN 
LED and press the SET key for an instant: at the same time, 
the SUN LED will remain on and the Sun Sensor enabling will 
be complete. It is possible to repeat the operation to disable 
the Sun Sensor.

5)

RAIN 

(Rain Sensor ON/OFF)

Deactivation of the Rain Sensor 

The device is supplied with the Rain Sensor enabled (RAIN ON 
LED).
The deactivation of the Rain Sensor can be carried out as fol-
lows: with the SEL key position yourself on the flashing of the 
RAIN LED and press the SET key for an instant: at the same 
time, the RAIN LED will switch off and the Rain Sensor deactiv-
ation will be complete. It is possible to repeat the operation to 
activate the Rain Sensor.

6)

TEST 

(Test Sensors ON/OFF)

The device is supplied with the Wind - Sun - Rain Test Sensors 
disabled (TEST OFF LED).
The activation of the Wind - Sun - Rain Test Sensors can be 
carried out as follows: with the SEL key position yourself on the 
flashing of the TEST LED and press the SET key for an instant: 
at the same time, the TEST LED will switch on and the activa-
tion of the Wind - Sun - Rain Test Sensors will be complete. It 
is possible to repeat the operation to disable the Test Sensors.

Anemometer  Test:

  manually  rotate  the  Anemometer  blades 

and, at the same time,    the WIND MONITOR LED will switch 
on, signalling the radio sending of the necessary information to 
the previously configured coupled control unit (signalled by the 
flickering of the CODE MONITOR LED), controlling the ascent 
for 5 sec.

Sun Sensor Test: 

rotate VR1 trimmer as far as possible clock-

wise (in + position) and, at the same time,  the SUN MONITOR 
LED will switch on, signalling   the radio sending of the neces-
sary information to the previously configured coupled control 
unit (signalled by the flickering of the CODE MONITOR LED), 
controlling the descent for 5 sec. Rotate the VR1 trimmer VR1 
anti-clockwise (in - position) and, at the same time,    the SUN 
MONITOR LED will switch off, signalling   the radio sending of 
the necessary information to the previously configured coupled 
control unit (signalled by the flickering of the CODE MONITOR 
LED), controlling the ascent for 5 sec.

Rain Sensor Test: 

 wet the sensitive part of the Rain Sensor 

and, at the same time,    the RAIN MONITOR LED will switch 
on, signalling the radio sending of the necessary information to 
the previously configured coupled control unit (signalled by the 
flickering of the CODE MONITOR LED), controlling the ascent 
for 5 sec.
Completed the test, ensure to have dried the sensitive part of 
the rain sensor before using the control unit in the normal func-
tioning.

SENSORS MONITOR 

    

The   control   unit   presents   four   "monitor"   indicator   LED   with 
which it is possible to display the radio transmission of the in-
formation relating to each sensor. 

---------------------- LEDS  MONITOR -----------------

LED Reference                  LED Off                            LED On

CODE MONITOR              Info = OFF                       Info = ON      
 WIND MONITOR              Info = OFF                       Info = ON      
 SUN MONITOR                Info = OFF                       Info = ON      
 RAIN MONITOR               Info = OFF                       Info = ON      

R

ESET

In case it is necessary to reset the control unit default factory 
configuration, press the SEL and SET keys together so that all 
indicator LED switch on and off at the same time.

2

Rev. 1.0      20/02/09

Отзывы: