Before   gate   automation,   it   is   necessary   to   check   the  

good condition of the gate and its compliance with EN  
12604 with respect to directive on machines.

The control unit is not equipped with 230 Vac electric  

line sectioning device. The installer is responsible for  
installing   a   sectioning   device   in   the   system.   The  
sectioning device must be protected against accidental  
closing in compliance with 5.2.9 section of EN 12453.

Wiring   of   external   electrical   components   must   comply  

with EN 60204-1 as amended  in section 5.2.7 of EN 
12453. The fixing of power supply leads and connection  
cables   must   be   secured   through   the   use   of   cable  
clamps supplied on demand.

If   present,   the   push-button   station   for   manual   control  

must be mounted in such a way that the user is not in a  
dangerous position.

The motor reducer used to move the gate must comply  

with section 5.2.7. of EN 12453.

The   D.S.   Power   Supply   output   must   be   dedicated   to 

photoelectric cell power supply. It must not be used for  
other applications.

The control unit tests the operation of photoelectric cells  

at   every   manoeuvring   cycle   to   guarantee   protection  
against   failures   of   anti-compression   devices   of  
Category   2  in  compliance   with   section   5.1.1.6  of  EN  
12453. Therefore, it safety devices are not connected  
and/or   operated,   the   control   unit   is   not   enabled   for  
operation.

The safety function guaranteed by the control unit is only  

active   during   closing;   therefore   protection   during  
opening   must   be   guaranteed   during   installation   with 
measurements   (shelters   or   safety   distances)   that   are  
independent from the control circuit. 

For the correct operation of the radio receiver, if two or  

more   control   units   are   used,   we   recommend   you   to  
install the devices  at least  3 metres  away  from each  
other.

SEAV s.r.l.

 hereby declares that the products below:

Electronic Control Unit:

LG 2186 -  LRS 2186 - LRS 2186 SET - LRH 2186

complies with requirements of Directives R&TTE 99/5/EC,  

EMC 2004/108/EC, LVD 2006/95/EC.

Rel. 1.1 of 12-03-07

Содержание LRX 2186

Страница 1: ... The selection of this operation mode is described in the Pause Time programming mode Pedestrian Passage Using both the pedestrian radio control CODE PED LED on and the low voltage push button station PED to control the shutter the following operation is obtained the first impulse controls opening for 10 seconds then the control unit makes a 10 second pause and closes the shutter Safety device The...

Страница 2: ... restore the previous configuration 5 LAMP CORT CO Selection of flashing beacon courtesy light or auxiliary contact The control unit is provided with a clean relay contact output to connect a flashing beacon courtesy light or auxiliary contact i e for garage light command The control unit is supplied by the manufacturer with the flashing beacon function enabled To enable the courtesy light follow ...

Страница 3: ...manufacturer with the maintenance of hydraulic motor pressure not enabled To enable the function follow this procedure check that the extended menu is enabled T MOT and T PAUSA LED s start flashing alternatively with the SEL key go to CODE PED LED when flashing and press the SET key the CODE PED LED turns on and programming is completed In this way the control unit will send a closing command to t...

Страница 4: ...453 The D S Power Supply output must be dedicated to photoelectric cell power supply It must not be used for other applications The control unit tests the operation of photoelectric cells at every manoeuvring cycle to guarantee protection against failures of anti compression devices of Category 2 in compliance with section 5 1 1 6 of EN 12453 Therefore it safety devices are not connected and or op...

Отзывы: