Seav LRX 2186 Скачать руководство пользователя страница 2

p.m. at the end of opening the control unit disables the flashing 
beacon, the automatic closing and the radio controls.

PROGRAMMING :

SEL key:

  it selects the type of function to store, selection is 

indicated by flashing LED.
By   pressing   the   key   repeatedly,   you   can   select   the   desired 
function.  The selection remains active for 10 seconds (flashing 
LED); after 10 seconds, the control unit returns to the original 
status.

SET key :

 it programmes the information according to the type 

of function selected with the SEL key.

IMPORTANT:

  The   function  of  the  SET key  can   be  replaced 

with the radio control, if programmed previously (CODE LED 
on).

MAIN MENU

The   control   unit   is   supplied   by   the   manufacturer   with   the 
possibility of selecting some important functions.

---------------------- MAIN MENU -----------------

LED status

LED off

                           

LED on

1)   FUN.   IN/OUT

   

PUL/PED   commands

         

2   x   PUL   IN/OUT 

commands
2) CODE

No code

              

Code entered

3) CODE PED.

No code

                           

Code entered

4) INB.CMD.AP

Not enabled

              

Enabled

5) LAMP/CORT/CO Flashing beacon

Courtesy Light- Aux Contact

6) THE ARIES EFFECT

 

Not enabled

              

Enabled

7) T. MOT.

30 sec. motor time

              

Programmed time

8) T. PAUSA.

Without aut. closing

              

With aut. closing

1)  IN/OUT FUNCTION:

The control unit is supplied by the manufacturer with the PUL 
and   PEL   PED   command   buttons   enabled   for   standard 
operation (FUNCTION IN/OUT LED off).  If you need to enable 
an  operation   mode  that   can  manage  a  traffic   light   for  traffic 
control before and after motion (FUNCTION IN/OUT LED on), 
follow   this   procedure:   with   the   SEL   key   go   to   FUNCTION 
IN/OUT   LED   when   flashing,   then   press   the   SET   key:   the 
FUNCTION IN/OUT LED turns on. Both 5-sec pause time and 
command   inhibition   during   opening   are   enabled.  Repeat   the 
operation to restore the default configuration.

2)  CODE : 

 (Radio control code)

The   control   unit   allows   for   storing   150   radio   control   with 
different code of fixed or rolling type.

Programming.

To programme the transmission code follow this procedure: 
with the SEL key go to CODE LED when flashing, send the 
desired code with the radio control; programming is completed 
when the CODE LEC remains on permanently.  If you have 
stored 150 codes and you repeat the programming operation, 
all programming LED’s start flashing to indicate that no codes 
can be stored.

Deleting the codes.

To delete all transmission codes stored in the memory, do as 
follows: press the SEL key, the CODE LED starts flashing, then 
press the SET key, the LED CODE turns off and the procedure 
is completed.

3)  CODE PED:

(Pedestrian radio control code).

The programming and deleting procedure is the same as the 
one illustrated above, with reference to the CODE PEDONALE 
LED.

4)  INB.   CMD.   AP:  

(command   inhibition   during   opening   and 

pause time, if entered)
The   command   inhibition   function   during   opening   and   pause 
time,   if   entered,   is   used   when   automation   includes   the   loop 
detector. During opening or pause the control unit ignores the 
commands given by the loop detector at every passage.

The   control   unit   is   supplied   by   default   with   the   command 
inhibition function during opening and pause time not enabled. 
To enable the function follow this procedure: with the SEL key 
go to INB.CMD.AP LED when flashing, then press the SET key: 
the INB.CMD.AP LED turns on. Repeat the operation to restore 
the previous configuration.

5)  LAMP/CORT/CO:  

(Selection   of   flashing   beacon,   courtesy 

light or auxiliary contact)
The control unit is provided with a clean relay contact output to 
connect a flashing beacon, courtesy light or auxiliary contact 
(i.e. for garage light command).
The   control   unit   is   supplied   by   the   manufacturer   with   the 
flashing beacon function enabled. To enable the courtesy light 
follow this procedure: with the SEL key go to LAMP/CORT/CO 
when flashing, then press the SET key: the LAMP/CORT/CO 
LED   turns   on.   To   enable   the   auxiliary   contact,   repeat   the 
operation   above,   by   pressing   the   SEL   key   twice 
(LAMP/CORT/CO LED flashes rapidly) instead of once.

Flashing Beacon Operation:

The   clean   relay   contact 

output will activate every time automation moves for the motor 
time.   If   the   Pause   Time   is   stored,   the   relay   contact   will   be 
active also during the Pause.

Courtesy Light Operation: 

The clean relay contact output will 

activate   for   3   minutes   every   time   an   opening   command   is 
given.

 

Auxiliary Contact Operation:  

The clean relay contact output 

will activate for 1 second every time an opening command is 
given.

6)  THE ARIES (RAMMING) EFFECT :

The   aries   (ramming)   effect  function   is   used   in   gates   with 
electric   locks   to   unlock   the   lock   and   permit   the   correct 
execution  of   the  opening  operation.   Before  starting   opening, 
the control unit will send a closing command for 2 seconds.
The control unit is supplied by the manufacturer with the aries 
(ramming) effect function not enabled. To enable the function 
follow this procedure: with the SEL key go to C. ARIETE LED 
when flashing, then press the SET key: the C. ARIETE turns 
on. Repeat the operation to restore the previous configuration.

7)  MOTOR   TIME   and   DECELERATION:

 

(Programming   motor 

operation time of max. 4 minutes)

The control unit is supplied by the manufacturer with predefined 
motor operation time of 30 seconds without deceleration.
To modify the motor operation time, follow this procedure with 
the shutter closed: with the SEL key go to T. MOT. LED when 
flashing, then press the SET key rapidly, the Motor starts the 
opening cycle; when the initial point of deceleration is reached 
press   the   SET   key   again,   the   motor   decelerates   until   the 
desired position is reached, press the SET key to complete the 
opening cycle. The T. MOT. LED starts flashing rapidly, now 
repeat   the   programming   operation   of   motor   time   and 
deceleration   for   the   closing   cycle.   To   deactivate   the 
deceleration  function, during programming, once the opening 
and closing cycle is completed, press the SET key twice in a 
sequence. 

During programming the radio control key of the control unit  
can be used instead of the SET key, if stored previously.

8) T. PAUSA:

 

(Programming of aut. closing time of max. 4 min.)

The   control   unit   is   supplied   by   the   manufacturer   without 
automatic   closing.   To   enable   automatic   closing   follow   this 
procedure: with the SEL key go to T. PAUSA when flashing, 
then press the SET key, wait for the desired pause time, then 
press the SET key again for a second; the automatic closing 
time is stored and the T. PAUSA LED is on.
To restore the initial configuration (without automatic closing) 
go to the T.PAUSA LED when flashing, then press the SET key 
twice within 2 seconds; the LED goes off and the operation is 
completed.

During programming the radio control key of the control unit  
can be used instead of the SET key, if stored previously.

EXTENDED MENU

Содержание LRX 2186

Страница 1: ... The selection of this operation mode is described in the Pause Time programming mode Pedestrian Passage Using both the pedestrian radio control CODE PED LED on and the low voltage push button station PED to control the shutter the following operation is obtained the first impulse controls opening for 10 seconds then the control unit makes a 10 second pause and closes the shutter Safety device The...

Страница 2: ... restore the previous configuration 5 LAMP CORT CO Selection of flashing beacon courtesy light or auxiliary contact The control unit is provided with a clean relay contact output to connect a flashing beacon courtesy light or auxiliary contact i e for garage light command The control unit is supplied by the manufacturer with the flashing beacon function enabled To enable the courtesy light follow ...

Страница 3: ...manufacturer with the maintenance of hydraulic motor pressure not enabled To enable the function follow this procedure check that the extended menu is enabled T MOT and T PAUSA LED s start flashing alternatively with the SEL key go to CODE PED LED when flashing and press the SET key the CODE PED LED turns on and programming is completed In this way the control unit will send a closing command to t...

Страница 4: ...453 The D S Power Supply output must be dedicated to photoelectric cell power supply It must not be used for other applications The control unit tests the operation of photoelectric cells at every manoeuvring cycle to guarantee protection against failures of anti compression devices of Category 2 in compliance with section 5 1 1 6 of EN 12453 Therefore it safety devices are not connected and or op...

Отзывы: