ELECTRONIC CONTROL UNIT LRX 2186

Single-phase electronic control unit for the automation of sliding 
or swinging gates with incorporated radio receiver.

- Mod. 

LG 2186

: Without radio receiver

- Mod. 

( LR    2186 )

: 306     Mhz

- Mod. 

( LR 2186 / 330 )

: 330     Mhz

- Mod. 

( LR 2186 / 418 )

: 418     Mhz

- Mod. 

LRS 2186

: 433.92 Mhz

- Mod. 

LRS 2186 SET

: 433.92 Mhz  narrow band

- Mod. 

LRH 2186

: 868.3 Mhz  narrow band

(  )

  Product   intended   for   those   countries   where   its   use   is 

permitted

TECHNICAL DATA:

- Power supply

: 230 Vac  50-60Hz 1100W max.

- Flashing beacon output : 230 Vac 500 W max.
- Motor output

: 230 Vac 500 W max.

- Electric lock output

: 12 Vdc  15 W max.

- Photoelectric cells power supply : 24 Vac 3 W max.
- Stop limit and low voltage commands

: 24 Vcc

- Operating temperature

: -10 

÷

70 °C

- Radio receiver

: see model

- Op. transmitters

: 12-18 Bit or Rolling Code

- Max TX stored codes

: 150 (CODE or CODE PED)

- Box dimensions

: 190x140x70 mm.

- Container:

:  IP56.

TERMINAL BOARD CONNECTIONS:

CN1:

1   : 230 Vac line input (Phase).
2   : 230 Vac line input (Neutral).
3   : Clean contact output for Flashing Beacon/Courtesy Light.
4   : Clean contact output for Flashing Beacon/Courtesy Light.
5   : Opening motor output.
6   : Common motor output.
7   : Closing motor output.

CN2:

1   : Photoelectric cells control and power supply (24 Vac).
2   : Photoelectric cells control and power supply (GND).
3   : 12 Vdc 15 W (+12V) electric lock output.
4   : 12 Vdc 15 W (GNC) electric lock output.
5   : PUL open-close command button input (NA).
6   : GND common input.
7   : PUL PED pedestrian command button input (NA).
8   : DS safety device input (NC).
9   : GND common input.
10 : BL block device input (NC).
11 : FCAP opening stop limit input (NC).
12 : GND common input.
13 : FCCH closing stop limit input (NC).
14 : Antenna earth input.
15 : Antenna hot pole input.

CN3:

1   : Output 1 for connection of Traffic Light Module ML 2192.
2   : Output 2 for connection of Traffic Light Module ML 2192.
3   : Output 3 for connection of Traffic Light Module ML 2192.

FUNCTIONAL DATA:

Step-by-Step Operation:

Using   both   the   radio   control   (CODE   LED   on)   and   the   low 
voltage   push-button   station   (PUL)   to   control   the   shutter,   the 
following operation is obtained:
the first impulse opens the shutter until the end of the motor 
time   or   until   the   opening   stop   limit   is   reached,   the   second 
impulse   closes   the   shutter;   if   an   impulse   arrives   before   the 
opening   stop   limit   is   reached,   the   control   unit  

stops  

motion 

both   during   opening   and   closing.   An   additional   command 
restarts motion in the opposite direction.

Automatic closing:

The   control   unit   can   close   the   shutter   automatically   without 
sending additional commands.
The selection of this operation mode is described in the Pause 
Time programming mode.

Pedestrian Passage :

Using both the pedestrian radio control (CODE PED. LED on) 
and the low voltage push-button station (PED) to control the 
shutter,  the   following   operation  is   obtained:   the   first   impulse 
controls opening for 10 seconds, then the control unit makes a 
10-second pause and closes the shutter.

Safety device:

The   control   unit   allows   for   powering   and   connecting 
photoelectric cells according to EN 12453.
The   action   is   not   considered   during   opening   and   causes 
inverted motion during closing.
The   control   unit   must   use   photoelectric   cells   connected   to 
dedicated inputs; otherwise the control unit is not enabled for 
operation.

Lock input:

The control unit provides for connection of a lock button (NC). 
The action in any operation stage stops motion immediately. An 
additional motion command will be valid as long as the lock 
input is deactivated, and in any case it will close the gate with 
5-second pre-flashing.
If not used, this input must be bridged.

Initial pick-up and Motor Power Adjustment:

The electronic control unit is equipped with initial pick-up and 
motor power adjustment  functions that are fully managed  by 
the microprocessor.  
The   initial  pick-up   function  is   used   to  help  the   motor  during 
initial motion by powering the motor with maximum power for 2 
seconds   also   when   the   motor   power   adjustment   function   is 
enabled.
The motor power adjustment function is used to ensure correct 
motion   and   at   the   same   time   block   the   shutter   in   case   of 
obstacles without causing harm to individuals or properties. 

Deceleration:

The motor deceleration function  is used  to avoid high-speed 
closing of swinging gates at the end of opening and closing.  
Deceleration can be programmed at the desired points (before 
total opening and closing) during Motor Time programming.

Traffic Light Management:

The control unit can manage two “Green/Red” traffic lights for 
traffic control before and during the gate automation (by means 
of connection to CN3 terminal board of optional accessory ML 
2192). If selected, (FUNCTION IN/OUT LED on) you can have 
two opening commands of the gate according to direction (i.e. if 
you   enter   or   exit).   The   two   commands   are   obtained   by 
modifying the operation of the inputs (PUL – PUL PED) and 
(CODE – CODE PED) that become operation commands for 
the entrance and exit direction.

Operation with TIMER:

The control  unit allows  for connecting  a timer instead of the 
open-close command button (PUL). 
Example: 8:00 a.m. the timer closes the contact and the control 
unit commands opening, 6:00 p.m. the timer opens the contact 
and the control unit commands closing. From 8:00 a.m. to 6:00 

I

Содержание LRX 2186

Страница 1: ... The selection of this operation mode is described in the Pause Time programming mode Pedestrian Passage Using both the pedestrian radio control CODE PED LED on and the low voltage push button station PED to control the shutter the following operation is obtained the first impulse controls opening for 10 seconds then the control unit makes a 10 second pause and closes the shutter Safety device The...

Страница 2: ... restore the previous configuration 5 LAMP CORT CO Selection of flashing beacon courtesy light or auxiliary contact The control unit is provided with a clean relay contact output to connect a flashing beacon courtesy light or auxiliary contact i e for garage light command The control unit is supplied by the manufacturer with the flashing beacon function enabled To enable the courtesy light follow ...

Страница 3: ...manufacturer with the maintenance of hydraulic motor pressure not enabled To enable the function follow this procedure check that the extended menu is enabled T MOT and T PAUSA LED s start flashing alternatively with the SEL key go to CODE PED LED when flashing and press the SET key the CODE PED LED turns on and programming is completed In this way the control unit will send a closing command to t...

Страница 4: ...453 The D S Power Supply output must be dedicated to photoelectric cell power supply It must not be used for other applications The control unit tests the operation of photoelectric cells at every manoeuvring cycle to guarantee protection against failures of anti compression devices of Category 2 in compliance with section 5 1 1 6 of EN 12453 Therefore it safety devices are not connected and or op...

Отзывы: