Seav LG 2218 Скачать руководство пользователя страница 3

 

Rev. 1.3      03/12/10 

wish  to  enable  the  other  operating  mode,  proceed  as  follows: 
enable the extended menu (the SUN and RAIN LEDs will flash 
to confirm this); use the SEL key to navigate to the M1 CODE 
LED,  then  press  the  SET  key  to  enable  the  Manual  function; 
use the SEL key to navigate to the M2 CODE LED, then press 
the  SET  key  to  enable  the  Venetian  blind  function,  or  use  the 
SEL key to navigate to the M1 CODE LED and M2 CODE LED, 
then press the SET key to enable the Step by step + Automatic 
Sensors function. 
 
C) CODE M3  
(Simultaneous or sequential start-up):  
The control unit is provided with simultaneous start-up of the 4 
motors already enabled. If you wish to have a 5-second interval 
in between the start-up of each motor, proceed as follows: en-
able  the  extended  menu  (the  SUN  and  RAIN  LEDs  flash  to 
confirm  this),  use  the  SEL  key  to  navigate  to  the  CODE  M3 
LED and then press the SET key; at the same time the CODE 
M3  LED  switches  on  permanently and programming is ended. 
Simply repeat this procedure to restore the previous configura-
tion.  
 
 
D) CODE M4 
(Programming the start-up delay time): 
The control unit allows you to program a start-up delay time for 
the 4 motors; this prevents other interconnected sets of 4 mo-
tors  from  starting  up  simultaneously.  The  control  unit  is  pro-
vided without start-up delay time for the 4 motors; to program a 
start-up delay time of between 1 and 120 seconds, proceed as 
follows:  enable  the  extended  menu  (the  SUN  and  RAIN  LEDs 
will  flash  to  confirm  this),  use  the  SEL  key  to  navigate  to  the 
CODE M4 LED, then press the SET key for the required delay 
time;  as  soon  as  you  release  the  key,  the  M4  CODE  LED 
switches  on  permanently  and  programming  is  complete.  Sim-
ply repeat this procedure to make any changes to the configu-
ration. 
 
E) SENS. CODE (Line Sensor Test): 
The control unit allows you to check operation of the connected 
sensors  and  correct  movement.  You  are  advised  to  install  the 
blind  with  it  half  open  to  check  the  confirmation  movements 
during  the  test.  Make  sure  you  disable  the  Line  Sensor  Test 
after checking the sensors’ operation. 
Anemometer  test:  turn  the  blades  manually;  the  control  unit 
will raise the blind for 5 seconds. 
Sun  sensor  test:  expose  the  Sun  Sensor  to  the  sun  or  light 
source;  the  control  unit  switches  on  the  SUN  LED  and  lowers 
the blind for 5 seconds. Cover the Sun Sensor and the control 
unit  will  switch  off  the  SUN  LED  and raise the blind for 5 sec-
onds. 
Rain sensor test: dampen the sensitive part of the Rain Sen-
sor; the control unit will switch on the RAIN LED and raise the 
blind for 5 seconds. At the end of the test, make sure you dry 
off the sensitive part of the rain sensor before using the control 
unit in normal operating mode.  
Programming: The control unit comes with a Line Sensor Test 
disabled.  If  you  wish  to  enable  the  Line  Sensor  Test,  proceed 
as  follows:  enable  the  extended  menu  (the  SUN  and  RAIN 
LEDs will flash to confirm this); use the SEL key to navigate to 
the  SENSOR  CODE  LED  and  then  press  the  SET  key;  at  the 
same time, the SENSOR CODE LED switches on permanently 
and  programming  is  complete.  Repeat  this  procedure  to  re-
store the initial configuration. 
 
F) T. MOT.  (Automatic Movement Lock):  
The  control  unit  allows  you  to  lock  automatic  movement  (Up-
ward or downward movement of the blind controlled by the Sun 
Sensor command or function of the Automatic Sensors); in this 
way, the control unit temporarily blocks automatic motion when 
a stop command is given during movement until the next rais-
ing  or  lowering  command.  The  control  unit  comes  with  the 
Automatic  Movement  Lock  disabled;  to  enable  this  function, 

proceed  as  follows:  enable  the  extended  menu  (the  SUN  and 
RAIN  LEDs  flash  to  confirm  this),  press  the  SEL  key  until  the 
T.MOT LED flashes, then press the SET key; at the same time 
the  T.MOT  LED  switches on permanently and programming is 
complete.  Repeat  this  procedure  to  restore  the  previous  con-
figuration. 
 
G) WIND SPEED (Safety Upward Movement) : 
The control unit comes with the Safety Upward Movement dis-
abled;  to  enable  this  function,  so  that  after  12  hours  of  the 
Wind  Sensor  being inactive the control unit automatically exe-
cutes the safety upward movement, proceed as follows: enable 
the  extended menu (the SUN and RAIN LED will flash to con-
firm  this),  press  the  SEL  key  until  the  WIND  SPEED  LED 
flashes,  then  press  the  SET  key;  at  the  same  time  the  WIND 
SPEED  LED  switches  on  permanently  and  programming  is 
complete.  Repeat  this  procedure  to  restore  the  previous  con-
figuration. 
 
 
 
H) SUN SENSOR (Sun sensor control inversion):  
The  control  unit  comes  with  the  Sun  control  =  Downward 
movement  control  association,  so  the  sensor  controls  the 
downward  movement  of  the  blind  when  it  detects  the  sun.  If 
you  wish  the  sun  sensor  to  control  the  upward  movement  of 
the  blind  when  it  detects  the  sun,  proceed  as  follows:  enable 
the extended menu (the SUN and RAIN LEDs flash to confirm 
this),  press  the  SEL  key  until  the SUN SENSOR LED flashes, 
then  press  the  SET  key;  at  the  same  time  the  SUN  SENSOR 
LED switches on permanently and programming is complete.  
Repeat this procedure to restore the previous configuration. 
 
I) RAIN SENSOR (Rain sensor control inversion): 
The  control  unit  comes  with  the  Rain  control  =  Upward  move-
ment  control  association,  so  the  sensor  controls  the  upward 
movement  of  the  shutter  when  it  detects  the  sun.  If  you  wish 
the rain sensor to control the downward movement of the shut-
ter when it detects the rain, proceed as follows: enable the ex-
tended  menu  (the  SUN  and  RAIN  LEDs  flash  to  confirm  this), 
press  the  SEL key until the RAIN SENSOR LED flashes, then 
press  the  SET key; at the same time the RAIN SENSOR LED 
switches on permanently and programming is complete.  
Repeat this procedure to restore the previous configuration. 
 

R

ESET

 

If  you  need  to  restore  the  control  unit’s  default  settings,  press 
the  SEL  and  SET  keys  together  to  switch  on  all  the  indicator 
LEDs  at  the  same  time  and  then  switch  them off again imme-
diately. 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

Содержание LG 2218

Страница 1: ...Z control lowering of the shutter sending a command for the same direction before the motor stops run ning the control unit stops the shutter sending a command for the opposite direction before the motor stops running the con trol unit reverses the movement Operation with General Keys The following type of operation is obtained by connecting the general command buttons normally open for movement a...

Страница 2: ...ed Simply repeat this procedure to disable the Sun Sensor 9 RAIN SENSOR Rain sensor ON OFF Disabling the rain sensor The control unit comes with a Rain Sensor enabled RAIN SENSOR LED ON The Rain Sensor can be disabled as follows use the SEL key to navigate to the RAIN SENSOR LED then press and hold the SET key for a second The RAIN SENSOR LED switches off and the Rain Sensor is disabled Simply rep...

Страница 3: ...the SUN and RAIN LEDs will flash to confirm this use the SEL key to navigate to the SENSOR CODE LED and then press the SET key at the same time the SENSOR CODE LED switches on permanently and programming is complete Repeat this procedure to re store the initial configuration F T MOT Automatic Movement Lock The control unit allows you to lock automatic movement Up ward or downward movement of the b...

Страница 4: ...e shutter in accordance with legislation in force The installer must comply with safety obligations and minimum re quirements Installation must be carried out according to EN 60335 2 97 Specification for safety of household and similar electrical ap pliances part 2 Particular requirements for drives for rolling shutters awnings blinds and similar equipment The control unit must be connected perman...

Страница 5: ...5 Rev 1 3 03 12 10 ...

Отзывы: