Seav LG 2218 Скачать руководство пользователя страница 2

 

Rev. 1.3      03/12/10 

 

---------------------- MAIN MENU ----------------- 

LED reference          LED off                                      LED on 

1) CODE M1                                                                    - 
2) CODE M2                                                                    - 
3) CODE M3                                                                    - 
4) CODE M4                                                                    - 
5) CODE SENS.                                                              - 
6) T. MOT.             Motor time 2 min.           Motor time Pgm. 
7) WIND SPEED    Wind safety 25 Km/h    Wind safety Pgm.                   
8) SUN SENSOR   Sun sensor = OFF            Sun sensor = ON                 
9) RAIN SENSOR  Rain sensor = OFF       Rain sensor = ON                 
10) SUN            Presence of Sun = No          Presence of Sun = Yes               
11) RAIN           Presence of Rain = No         Presence of Rain = Yes                 

1)  CODE M1  Not used in this model 

2)  CODE M2  Not used in this model 

3)  CODE M3  Not used in this model 

4)  CODE M4  Not used in this model 

5)  CODE SENS.  Not used in this model 

 
6)  LED T. MOT. (Programming Motor Time, max 4 minutes)  

The control unit comes with a motor power time set at two min-
utes (LET T.MOT. OFF). 
The motor time must be programmed as follows when the shut-
ter is down:  
Press  the  SEL  key  until  the  LED  T.MOT  key  flashes,  then 
press  and  hold  the  SET  key  to  raise  the  shutter;  release  the 
key  when  the  blind  is  at  the  required  point;  the  motor  time  is 
stored at the same time and the LED T.MOT key stays ON. 
If  you  are  using  an  automation  system  with  a  stop  limit,  we 
recommend  that  you  store  a  time  that  exceeds  the  shutter’s 
stop limit by a few seconds. 
If  you  require  unlimited  motor  time,  follow  the  same  program-
ming  instructions  holding  down  the  SET  key  for  less  than  two 
seconds;  the  LED  T.MOT  stays  ON  and  the  unlimited  time  is 
set.  The  operation  may  be  repeated  if  a  mistake is made dur-
ing programming. 
 
7)  WIND SPEED (Programming Wind Threshold)  

Displaying the programmed Wind threshold  
The wind safety threshold selection is displayed as follows: use 
the  SEL  key  to  navigate  to  the  WIND  SPEED  LED;  the  LED 
then  indicates  the  wind  safety  threshold,  whereby  every  dou-
ble-flash of the WIND SPEED LED indicates an increment of 5 
km/h (e.g. the WIND SPEED LED flashes 5 times = 25 km/h).  
Setting the wind safety threshold between 5 and 40 Km/h 
The control unit comes with a wind safety threshold already set 
at 25 km/h (WIND SPEED LED OFF). 
The  wind  safety  threshold  is  programmed  as  follows:  use  the 
SEL key to navigate to the WIND SPEED LED, then press the 
SET key to start programming; the WIND SPEED LED will then 
begin  to  double-flash  (each  double  flash  of  the  WIND  SPEED 
LED  corresponds  to  an  increment  of  5  km/h).  Press  the  SET 
key  once  the  required  threshold  has  been  reached.  The  se-
lected threshold is stored and the WIND SPEED LED stays ON 
(e.g. the WIND SPEED LED flashes 5 times = 25 km/h)
The  operation  may  be  repeated  if  a  mistake  is  made  during 
programming.  
 
8)  SUN SENSOR (Sun Sensor ON/OFF) 

Enabling the sun sensor 
The  control  unit  comes  with  a  Sun  Sensor  disabled  (SUN 
SENSOR LED OFF). 
The Sun Sensor can be enabled as follows: use the SEL key to 
navigate to the SUN SENSOR LED then press the SET key for 
a second. The SUN SENSOR LED stays ON at the same time. 
The Sun Sensor is now enabled. Simply repeat this procedure 

to disable the Sun Sensor. 
 
9)  RAIN SENSOR (Rain sensor ON/OFF) 

Disabling the rain sensor 
The  control  unit  comes  with  a  Rain  Sensor  enabled  (RAIN 
SENSOR LED ON). 
The Rain Sensor can be disabled as follows: use the SEL key 
to  navigate  to  the  RAIN  SENSOR  LED,  then  press  and  hold 
the  SET  key  for  a  second.  The  RAIN  SENSOR  LED  switches 
off  and  the  Rain  Sensor  is disabled. Simply repeat this proce-
dure to enable the Rain Sensor. 
 

EXTENDED MENU

 

The manufacturer provides the control unit with only the option 
of selecting the functions of the main menu. 
If you wish to enable the functions of the extended menu, pro-
ceed as follows: press and hold the SET key for 5 seconds; the 
SUN  and  RAIN  LEDs  will  flash  alternately;  you  then  have  30 
seconds  within  which  to  select  the  functions  of  the  extended 
menu  using  the  SEL  and  SET  keys;  after another 30 seconds 
the control unit returns to the main menu.  
 
 
 
 
 

---------------------- EXTENDED MENU ----------------- 

LED reference          LED off                        LED on 

A) CODE M1         Step by step                Manual/ P-P S. Aut.       
B) CODE M2         Step by step              Venetian blind / P-P S. Aut.      
C) CODE M3   Simultaneous start-up     5 sec sequential start-up      
D) CODE M4    Start-up delay time = OFF  Start-up delay time= Pgm 
E) CODE SENS.   Line Sensor test = OFF       Line Sensor test = ON      
F) T. MOT.            Aut shutdown = OFF            Aut shutdown = ON      
G) WIND SPEED   Safety up movmt = OFF   Safety up movmt = ON                   
H) SUN SENSOR  RAIN inversion = OFF       RAIN inversion = ON                
I) RAIN SENSOR   SUN inversion = OFF        SUN inversion = ON                
L) SUN                                    ON/OFF intermittent                   
M) RAIN                                  ON/OFF intermittent                   

 
A – B ) CODE M1 – M2 
(4 different selectable operating logics):  
 
Step by step:

 

Step  by  step  operation  is  possible  using  the  pushbutton  con-
trol.  The  first  impulsive  control  raises  the  blind  for  the  motor 
time.  The  second  impulsive  control  lowers  the  blind.  If  an  im-
pulsive  command  is  sent  before  the  motor  stops  running,  the 
control  unit  stops  the  blind;  another  impulsive  command  re-
activates the blind in the opposite direction. 
Manual: 
Manual operation is possible using the pushbutton control. The 
control  needs to be constantly enabled to move the blind. Re-
leasing the key will always stop operation. 
Venetian blind operation: 
The  Venetian  blind  mode  involves  manual  operation  for  the 
first 2 seconds using pushbutton control; this allows you to turn 
the  slats  of  the  Venetian  blind  ever  so  slightly  to  let  more  or 
less light into the room as required. If the commands are more 
than  2  seconds,  the  blind  is  raised  or  lowered  depending  on 
the key pressed, until the motor stops running. 
Step by step + Automatic sensors:  
The  control  unit  enables  step  by  step  operation  as  above,  as 
well as automatic management of the Wind and Rain sensors. 
Ten minutes after the wind or rain that activated one of the two 
sensors, the control unit lowers the blind. 
Selection mode: 
The  control  unit  allows  you  to  select  4  different  operating  lo-
gics:  step  by  step,  manual,  Venetian  blind  and  step  by  step  + 
automatic sensors. 
The control unit is provided with step by step operation already 
enabled (M1 CODE LED AND M2 CODE LED disabled). If you 

Содержание LG 2218

Страница 1: ...Z control lowering of the shutter sending a command for the same direction before the motor stops run ning the control unit stops the shutter sending a command for the opposite direction before the motor stops running the con trol unit reverses the movement Operation with General Keys The following type of operation is obtained by connecting the general command buttons normally open for movement a...

Страница 2: ...ed Simply repeat this procedure to disable the Sun Sensor 9 RAIN SENSOR Rain sensor ON OFF Disabling the rain sensor The control unit comes with a Rain Sensor enabled RAIN SENSOR LED ON The Rain Sensor can be disabled as follows use the SEL key to navigate to the RAIN SENSOR LED then press and hold the SET key for a second The RAIN SENSOR LED switches off and the Rain Sensor is disabled Simply rep...

Страница 3: ...the SUN and RAIN LEDs will flash to confirm this use the SEL key to navigate to the SENSOR CODE LED and then press the SET key at the same time the SENSOR CODE LED switches on permanently and programming is complete Repeat this procedure to re store the initial configuration F T MOT Automatic Movement Lock The control unit allows you to lock automatic movement Up ward or downward movement of the b...

Страница 4: ...e shutter in accordance with legislation in force The installer must comply with safety obligations and minimum re quirements Installation must be carried out according to EN 60335 2 97 Specification for safety of household and similar electrical ap pliances part 2 Particular requirements for drives for rolling shutters awnings blinds and similar equipment The control unit must be connected perman...

Страница 5: ...5 Rev 1 3 03 12 10 ...