Seav LG 2218 Скачать руководство пользователя страница 1

 

Rev. 1.3      03/12/10 

LG 2218 electronic control unit 

An electronic control unit for the automation of 4 motors for roll-
ing window shutters and/or sun blinds, with optional connection 
of Wind, Sun and Rain. 
 

T

ECHNICAL 

S

PECIFICATIONS

 

- Power supply: 

230V~ 50/60Hz 1700W max. 

- Motor output: 

230V~ 400W Max. 

- Working temperature: 

-10 to 55°C 

- Packaging dimensions:                               190x140x70 mm. 
- Container:                                           ABS  UL94V-0  ( IP65 ) 

C

ONNECTION OF 

CN1

 

T

ERMINAL 

B

OARD

 

1:  ~230V line input (Phase). 
2:  ~230V line input (Neutral). 
3:  Motor 1 Upward movement output. 
4:  Motor 1 Shared output. 
5:  Motor 1 Downward movement output. 
6:  Motor 2 Upward movement output. 
7:  Motor 2 Shared output. 
8:  Motor 2 Downward movement output  
9:  Motor 3 Upward movement output. 
10:  Motor 3 Shared output. 
11:  Motor 3 Downward movement output  
12:  Motor 4 Up output. 
13:  Motor 4 Shared output. 
14:  Motor 4 Downward movement output. 

C

ONNECTION OF 

CN2

 

T

ERMINAL 

B

OARD

 

1:  U1 Upward movement Local Input (NO). 
2:  GND shared Signal Input 
3:  D1 Downward movement Local Input (NO). 
4:  U2 Upward movement Local Input (NO). 
5:  GND shared Signal Input 
6:  D2 Downward movement Local Input (NO). 
7:  U3 Upward movement Local Input (NO). 
8:  GND shared Signal Input 
9:  D3 Downward movement Local Input (NO). 

10:  U4 Upward movement Local Input (NO). 
11:  GND shared Signal Input 
12:  D4 Downward movement Local Input (NO). 

 

CN3

 

T

ERMINAL 

B

LOCK 

C

ONNECTIONS

 

1:  24 Vac Sun Sensor Power Output  
2:  “S” Sun Sensor Input (NO). 
3:  GND shared Input / 0 Vac Output  
4:  “R” Rain Sensor Input (NO). 
5:  GND shared Input  
6:  “W” Wind Sensor Input. 
7:  UZ Upward movement Zone Input (NO). 
8:  GND shared Input  
9:  DZ Downward movement Zone Input (NO). 

10:  UG Upward movement General Input (NO). 
11:  GND shared Input  
12:  DG Downward movement General Input (NO). 

 
 

I

NITIAL 

O

PERATING 

C

ONDITION

 

The  control  unit  allows  you  to  control  the  4  motors  independ-
ently  using  the  Local  U1-2-3-4  (Up)  or  D1-2-3-4  (Down)  con-
trols, and the UZ (Up zone), DZ (Down zone) and general UG 
(Up) and DG (Down) simultaneous control keys. It is also pos-
sible to control the 4 motors together or independently.  

FUNCTIONAL PROPERTIES: 

Operation with Local Control or Zone Keys: 

Connection to the U1-U2-U3-U4-UZ and D1-D2-D3-D4-DZ low 
voltage inputs of the local control keys (normally open) for run-

running the shutter will ensure the following operation: 
U1-U2-U3-U4-UZ control raising for the configured motor time, 
D1-D2-D3-D4-DZ  control  lowering  of  the  shutter;  sending  a 
command  for  the  same  direction  before  the  motor  stops  run-
ning, the control unit stops the shutter; sending a command for 
the opposite direction before the motor stops running, the con-
trol unit reverses the movement. 
 
Operation with General Keys:  

The  following  type  of  operation  is  obtained  by  connecting  the 
general  command  buttons  (normally  open)  for  movement  acti-
vation to the low voltage inputs UG – DG: 

 

UG  controls  upward  movement  until  the  motor  running  time 
has  elapsed  and  DG  controls  downward  movement.  If  a  com-
mand  is  sent  in  the  same  direction  before  the  motor  running 
time has elapsed, the control unit will ignore the command; if a 
command  is  sent  in  the  opposite  direction  before  the  motor 
running  time  has  elapsed,  the  control unit will invert the direc-
tion of the motor. 

Z

ONE AND 

G

ENERAL 

C

ENTRALIZATION

 

Centralization with cable and keys 
The centralization of two or more control units via wire enables 
simultaneous raising or lowering of the connected shutters. To 
do  this  you  need  to  connect  the  control  units  with  a  bus  of 
three wires in parallel to the inputs of the General UG (Up) and 
DG  (Down)  commands  and  the  “GND  Signal”  common  refer-
ence. 
This allows you to control the 4 motors independently or simul-
taneously  with  the  UZ  (Up)  and  DZ  (Down)  zone  commands 
and  centralize  other  control  units  with  the  UG  (Up)  and  DG 
(Down) general commands. 
 

A

NEMOMETER OPERATION

 

The  electronic  control  unit  raises the sun shade whenever the 
wind exceeds the selected threshold. 

S

UN 

S

ENSOR OPERATION

 

The electronic control unit lowers the sun shade after 10 min-
utes of brightness greater than the Sun Sensor’s selected 
threshold; this is indicated by the SUN LED which lights up. 
The control unit then raises the blind after 10 minutes during 
which the brightness is below the selected threshold. 

R

AIN 

S

ENSOR OPERATION

 

The electronic control unit raises the blind as soon as the sen-
sitive part of the rain sensor is touched by water. The RAIN 
LED lights up. 

P

ROGRAMMING 

K

EYS AND 

I

NDICATOR 

L

ED 

 

SEL  key:  this  selects  the  function  to  be  stored.  The  LED 
flashes to indicate your selection. Keep pressing the key to find 
the required function. The selection remains active for 15 sec-
onds  (during  which  time  the  LED  keeps  flashing)  after  which 
the control unit then returns to its original state. 

SET key: this key programs the function selected with the SEL 
key. 

 
Indicator LED
 
LED on: stored option.  
LED off: option not stored.  
LED flashing: option selected.  

 

 

 

 

GB 

Содержание LG 2218

Страница 1: ...Z control lowering of the shutter sending a command for the same direction before the motor stops run ning the control unit stops the shutter sending a command for the opposite direction before the motor stops running the con trol unit reverses the movement Operation with General Keys The following type of operation is obtained by connecting the general command buttons normally open for movement a...

Страница 2: ...ed Simply repeat this procedure to disable the Sun Sensor 9 RAIN SENSOR Rain sensor ON OFF Disabling the rain sensor The control unit comes with a Rain Sensor enabled RAIN SENSOR LED ON The Rain Sensor can be disabled as follows use the SEL key to navigate to the RAIN SENSOR LED then press and hold the SET key for a second The RAIN SENSOR LED switches off and the Rain Sensor is disabled Simply rep...

Страница 3: ...the SUN and RAIN LEDs will flash to confirm this use the SEL key to navigate to the SENSOR CODE LED and then press the SET key at the same time the SENSOR CODE LED switches on permanently and programming is complete Repeat this procedure to re store the initial configuration F T MOT Automatic Movement Lock The control unit allows you to lock automatic movement Up ward or downward movement of the b...

Страница 4: ...e shutter in accordance with legislation in force The installer must comply with safety obligations and minimum re quirements Installation must be carried out according to EN 60335 2 97 Specification for safety of household and similar electrical ap pliances part 2 Particular requirements for drives for rolling shutters awnings blinds and similar equipment The control unit must be connected perman...

Страница 5: ...5 Rev 1 3 03 12 10 ...

Отзывы: