Back view and cable assignment
2
2.1 AIS6
1.
Connection for power supply
Here you can connect the supplied 2-Pin powercable which includes a build-in 0.5A
fuse.
Pin
Color
Description
1
Black
- 12 / 24 Volt DC
2
White
+ 12 / 24 Volt DC
2.
Datacable Connector
To insert or retrieve NMEA data, you need to connect the datacable here.
Pin
Color
Baudrate
Description
1
Brown
4.800
NMEA Input +
2
Red
4.800
NMEA Input +
3
Orange
4.800
NMEA Input +
4
Yellow
4.800
NMEA Input +
5
Green
-
NMEA Input - (Ground)
6
Blue
38.400
NMEA
7
Purple
-
Option
8
White
-
NMEA Output - (Ground)
3.
VHF Antenna IN
Connect your VHF Antenna here (P/L Plug).
Hint: We recommend the VHF-Antenna RA106 (SVB-Art.: 73101)
4.
VHF Antenna OUT
Connect your VHF here.
Normally you will need a P/L - P/L connection cable (SVB Art. No.: 95508).
Great connectivity!
The Seatec technology is based on proven and reliable data communication methods. This in-
cludes the sending of AIS NMEA data and receiving of wind, autopilot, depth and speed data.
These information can be integrated from external devices.
5. Thumbscrews
The two included thumbscrews are used to secure the device with the mounting
bracket. This allows also an “upside-down” mounting.
6.
Electrical grounding
To avoid mutual interference, the unit must be grounded.