3.    Connection and installation of the 

MobilGate-128d

The connection points of the interface can be found in the figure below:

Up:             Antenna
                  USB connector
Down:        Relay outputs
                  Input connectors
                  Power supply connector

 

The power connection needs 10-30V DC supply

voltage. The inputs of the

MobilGate-128d

GSM gate

controller can be triggered by voltage-less contact on
the simple inputs. The numbering of the module inputs
is marked on the board of printed circuit. It has high
current No-Com type relay outputs and their max load
is 48V and 1A. The No and Com points of the relays
are wired out. The GSM modem has a screwed SMA
aerial  connector  and a small-sized  straight pole aerial

or an aerial with a coax cable or similar plug can also be installed to it. The power input of the GSM
gate opener module is protected against reverse polarity and it is equipped with 500mA multifuse.
The input voltage on the general purpose inputs ranges is from 5V ... 30Vdc. 

4.    

Configuring MobilGate-128d  using a computer:

MobilGate-128d

can be configured with computer or notebook via USB-port by using our

free software. A SIM card that is able to send SMS and it is not protected with PIN code has to be
isrequired for Windows XP or any newer operation system. After driver installation, the next step is
inserted into the module. When the device is connected to the USB-port, the module driver has to be

 SeaSoft  Ltd.    

                www.seasoft.hu  -  www.mobil-control.eu                    T: (+36) 62 406405       M: (+36) 30 2557688        F: (+36) 62 405-969  

Содержание MobilGate - 128d

Страница 1: ...input and output can be labeled with a max 16 character long name The configuration of the SMS relay output commands which trigger the relays to be on or off also can be set The module has a 4 charact...

Страница 2: ...icate possible error messages in the following order Red On LED Continuously The interface is operational It has to remain lit after turning it on White GSM LED Blinking GSM module operational status...

Страница 3: ...and a small sized straight pole aerial or an aerial with a coax cable or similar plug can also be installed to it The power input of the GSM gate opener module is protected against reverse polarity an...

Страница 4: ...are then set the Com value in Settings Port configuration menu The download software of MobilGate 128d offers a fast and simple way to configure the device Menus appearing on the screen allows the acc...

Страница 5: ...can be read and it results in overwriting data on the screen with the uploaded data It is advised to check downloaded data with the yellow colored Verify Download button The Check Status function quer...

Страница 6: ...for configuration MobilGate 128d functional memory map Memory Function contents Remarks Default Progr samples 00 Provider s SMS center number International format 36309888000 01 Device PIN code 4 cha...

Страница 7: ...0 SMS center number in international format here hungarian T Mobile i e 1234 W01 5678 where 5678 device PIN W01 memory place is PIN code giving command 5678 new PIN code i e 1234 W02 5566 where 5566 n...

Страница 8: ...rst user phone number can be queried i e 1234 R where R if there is no number after it it shows device status Response SMS in case of Default settings 1234 My house Gate motor ok Pushbutton released L...

Страница 9: ...seconds and it will be operational after registering to a GSM network e All members of the MobilGate family can operate only with SIM cards that are not protected with PIN codes Please note that the...

Страница 10: ...Appendix modificatons of of setting of USB serial Com port in Windows 7 step by step SeaSoft Ltd www seasoft hu www mobil control eu T 36 62 406405 M 36 30 2557688 F 36 62 405 969...

Отзывы: