SeaSoft MobilGate - 128d Скачать руководство пользователя страница 1

MobilGate - 128d

Gate and barrier control GSM module with

2 inputs and 2 outputs for 128 phone numbers

       

 

MobilGate-128d

 is an industrial GSM module developed for remotely controlling doors, garage

doors and barriers with 2 voltage-less contact type inputs and 4 low voltage low current relay
outputs. The 2 relay outputs allow the configuration of 128 phone numbers to control the gates
remotely with a free call based on caller ID recognition. The 2 relay outputs can be triggered by
SMS orders  received  from previously configured  phone numbers.  Relays operated  with a free call

can be triggered for pre-determined duration, and the relays operated
with SMSs can be turned on and off permanently. The recognition of
maximum 128 phone numbers allows to set up entitlements for 128
users. The general inputs can be used arbitrarily for transmitting gate
error signals, burglary alarm center's signals or panic signals. Users
are informed about input changes via SMS with pre-configured
content. Certain electronic devices, such as heaters, air conditioners,
light devices etc. can be turned on and off with relay outputs
operated via SMSs, thus the function of gate opener can be
broadened with many supplements. Its power voltage is 10-30Vdc,
which can be supplied by a power adapter. Its setup can be
configured with our free downloader software via USB port, or by
sending several different configuration SMS remotely. Each input
and output can be labeled with a max. 16-character long name. The
configuration of the SMS relay output commands which trigger the
relays to be on or off also can be set. The module has a 4-character
passcode in order to prevent any unauthorized personnel to disable
or reconfigure the module. The module has internal timers, thus the
output relays  are triggered  for a  configured time  when calls occur,

which can be maximum of 9999 seconds (about 3 hours). After the given time expires, the relays
turn off automatically and return to their original state.

1.    Operation of MobilGate-128d

The GSM gate opener is equipped with a carrier-

independent industrial GSM module; thus it is ready for
an SMS communication with a prepaid or subscription
SIM card without PIN code. The data which is necessary
for operation, for instance SMS number of the service
provider, users’ numbers, output and input names etc. can
be configured by downloading them into the device or
sending an SMS with a certain content. In the case there
is any change of the inputs, the module name, module
number, the appropriate input name and status are also
sent via SMS. The detailed messages provide possibility
to be able to easily identify the appropriate device  in case

of having more than one. Input and output status with every parameter can be queried by sending a
corresponding SMS. Configuration SMSs are confirmed after reception, and and an correct
configuration SMS will result in an error message.  The  module does  not discard  the previously set

 SeaSoft  Ltd.    

                www.seasoft.hu  -  www.mobil-control.eu                    T: (+36) 62 406405       M: (+36) 30 2557688        F: (+36) 62 405-969  

Содержание MobilGate - 128d

Страница 1: ...input and output can be labeled with a max 16 character long name The configuration of the SMS relay output commands which trigger the relays to be on or off also can be set The module has a 4 charact...

Страница 2: ...icate possible error messages in the following order Red On LED Continuously The interface is operational It has to remain lit after turning it on White GSM LED Blinking GSM module operational status...

Страница 3: ...and a small sized straight pole aerial or an aerial with a coax cable or similar plug can also be installed to it The power input of the GSM gate opener module is protected against reverse polarity an...

Страница 4: ...are then set the Com value in Settings Port configuration menu The download software of MobilGate 128d offers a fast and simple way to configure the device Menus appearing on the screen allows the acc...

Страница 5: ...can be read and it results in overwriting data on the screen with the uploaded data It is advised to check downloaded data with the yellow colored Verify Download button The Check Status function quer...

Страница 6: ...for configuration MobilGate 128d functional memory map Memory Function contents Remarks Default Progr samples 00 Provider s SMS center number International format 36309888000 01 Device PIN code 4 cha...

Страница 7: ...0 SMS center number in international format here hungarian T Mobile i e 1234 W01 5678 where 5678 device PIN W01 memory place is PIN code giving command 5678 new PIN code i e 1234 W02 5566 where 5566 n...

Страница 8: ...rst user phone number can be queried i e 1234 R where R if there is no number after it it shows device status Response SMS in case of Default settings 1234 My house Gate motor ok Pushbutton released L...

Страница 9: ...seconds and it will be operational after registering to a GSM network e All members of the MobilGate family can operate only with SIM cards that are not protected with PIN codes Please note that the...

Страница 10: ...Appendix modificatons of of setting of USB serial Com port in Windows 7 step by step SeaSoft Ltd www seasoft hu www mobil control eu T 36 62 406405 M 36 30 2557688 F 36 62 405 969...

Отзывы: