6. Query SMS commands
:
i.e.
!
1234,R00
where
R00
the 00
th
memory place
of the device (see table) carrier
SMS number can be queried.
i.e.
!
1234,R28
where
R28
the 28
th
memory place
of the device (see table) first user
phone number can be queried.
i.e.
!
1234,R
where
R
if there is no number after it, it shows device status.
Response SMS
in case of Default settings:
1234 My house Gate: motor ok Pushbutton: released Light off Buzzer off
This SMS informs about:
–
the valid device PIN code
- 1234
–
the actual nema of device
- My house
–
the name of 1
st
input
- Gate
–
the status of 1
st
input
- motor ok
–
the name of 2
nd
input
- Pushbutton
–
the status of 2
nd
input
- released
–
the status of sms switchable relay no.3
- Light off
–
the status of sms switchable relay no.4
- Buzzer off
7. Output configuration commands
i.e.
Light on
where
Light on
command is on
M09
memory place command which
(see table) is the retraction command of relay 3. Relay 3 will turn on.
Attention !
The device will execute the given command if it is identical to the command given in
the memory. If the sent SMS does not match with any SMS command, the module
will send back an
Error!
message.
8. Further notes
Regarding to the device functionality, GSM networks and the specialty of GSM voice calls
and SMS-s, the module requires further remarks:
a) The device can be operated with any microSIM card
b) The received unknown SMS-s, including the ones sent from the carrier (including the balance check
SMS) are forwarded to the first telephone number, if the first telephone number is specified in the
configuration.
c) If a pre-paid SIM card is used and the balance reaches zero, the device can remain operational
however it cannot send further SMS-s or initiate calls. In this case it is advised to regularly check the
balance of the card.
SeaSoft Ltd.