6.   Query SMS commands

:

i.e.

!

1234,R00

where 

R00 

 the 00

th

  memory place 

 of the device (see table) carrier 

SMS number can be queried.

            

i.e.

!

1234,R28

where 

R28  

the 28

th

 

memory place 

 of the device (see table) first user 

phone number can be queried.

i.e.

!

1234,R

where 

if there is no number after it, it shows device status.

 
   

Response SMS

  

in case of Default settings: 

 

                 

1234  My house   Gate: motor ok   Pushbutton: released    Light off   Buzzer off

   This SMS informs about:

  the valid device PIN code                        

-   1234

  the actual nema of device    

       

-   My house

  the name of 1

st

 input

       

-   Gate

  the status of 1

st

 input

   

    

-   motor ok

  the name of 2

nd

 input 

       

-   Pushbutton

  the status of 2

nd

 input                               

-   released

  the status of sms switchable relay no.3     

-  Light off

  the status of sms switchable relay no.4     

-  Buzzer off

 

7.   Output configuration commands

i.e.

Light on

where      

Light on

 

command is on

 

M09 

memory place command which 

    (see table) is the retraction command of relay 3. Relay 3 will turn on.

Attention !

The device will execute the given command if it is identical to the command given in

the memory. If the sent SMS does not match with any SMS command, the module
will send back an  

Error!

  message.

8.      Further notes

Regarding to the device functionality, GSM networks and the specialty of GSM voice calls

and SMS-s, the module requires further remarks:
 

a) The device can be operated with any microSIM card

b) The received unknown SMS-s, including the ones sent from the carrier (including the balance check

SMS) are forwarded to the first telephone number, if the first telephone number is specified in the
configuration.

c) If a pre-paid SIM card is used and the balance reaches zero, the device can remain operational

however it cannot send further SMS-s or initiate calls. In this case it is advised to regularly check the
balance of the card.

 SeaSoft  Ltd.    

                www.seasoft.hu  -  www.mobil-control.eu                    T: (+36) 62 406405       M: (+36) 30 2557688        F: (+36) 62 405-969  

Содержание MobilGate - 128c

Страница 1: ... which trigger the relays to be on or off also can be set The module also has a 4 character passcode in order to prevent any unauthorized personnel to disable or reconfigure the module The GSM gate opener has internal timers thus the output relays are triggered for a configured time when calls occur which can be maximum of 9999 seconds about 3 hours After the given time expires the relays turn off...

Страница 2: ...tinuously The interface is operational It has to remain lit after turning it on White GSM LED Blinking GSM module operational status It has to light up after around 25 seconds then flash according to its functioning Its flashing indicated that the device is connected to the network Green Heartbit LED Blinking It is the life signal of the device When the device is turned on it does not blink until ...

Страница 3: ... maximalum load is 230V and 8A The No Com and Nc points of the relays are wired out The GSM modem has a screwed SMA aerial connector and a small sized pole aerial or an aerial with a coax cable or similar plug can also be installed to it The power input of the GSM gate opener module is protected against reverse polarity and it is equipped with 500mA multifuse The input voltage on the general purpo...

Страница 4: ...bilGate 128 controller freely in configuration mode If the software cannot find the port of the device indicated on the picture it has to be identified manually in Windows by the followings Control Panel System Hardware Devices Ports The GSM device has to be identified by which serial port from Com1 Com99 it is connected to Manual configuration is necessary when previously a lot of USB devices had...

Страница 5: ...Ss it can be read and checked It is advised to always start configuration with a file named Default mob It is easier to edit uploaded data without making any mistake than creating new values It is important to fill out the required fields and avoid the use of accented characters for names and commands because the module does not recognize accented characters Fill the phone numbers in international...

Страница 6: ...n by the output status on screen located below the inputs statuses The software can handle every version of the MobilGate family It automatically recognizes the 32 and 128 version of the device family and it allows to open the group of mobile numbers beyond 32 in case of the 128 version After finishing the configuration please reset the module to verify the changes It can be done by clicking on th...

Страница 7: ...rs 1234 9876 02 Device identifier 4 scharacters 0001 0007 03 Name of device Max 16 characters My house My castle 04 Restore report of inputs 0 no 1 yes 1 1 05 Name of input 1 Max 16 characters Gate Barrier 06 Name of input 2 Max 16 characters Pushbutton Alarm system 07 Relay s switch on time Between 0 9999 sec 0005 0012 08 Switch on SMS command of relay 3 Max 16 characters Light on alarm on 09 Swi...

Страница 8: ...ll switch on for the given time when called 36 30 1234 567 last 11 characters means the phone number on memory place 29 Using the two tables above with the same logic with using the correct syntax for the given memory space every memory space can be loaded via an SMS Default settings remain in the unchanged memory spaces Loading memory spaces by SMSs can take some time therefore it is advised to u...

Страница 9: ... place command which see table is the retraction command of relay 3 Relay 3 will turn on Attention The device will execute the given command if it is identical to the command given in the memory If the sent SMS does not match with any SMS command the module will send back an Error message 8 Further notes Regarding to the device functionality GSM networks and the specialty of GSM voice calls and SM...

Страница 10: ...howing the caller ID must be enabled This can be performed by contacting the carrier s customer service h Call forwarding and SMS reminders about missed calls sent by the carrier must be disabled on the SIM card 9 Connecting the MobilGate 128c 10 Specifications Power supply 10 30 Vdc GSM Dual band Max Current 290 mA Frequency 900 1800MHz Stdby current relays on 27 mA Communication SMS voice Stdby ...

Страница 11: ...Appendix modificatons of of setting of USB serial Com port in Windows 7 step by step SeaSoft Ltd www seasoft hu www mobil control eu T 36 62 406405 M 36 30 2557688 F 36 62 405 969 ...

Отзывы: