background image

Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol. When you see this

symbol on your pump or in this manual, look for one

of the following signal words and be alert to the potential
for personal injury!

DANGER  warns about hazards that will

cause serious personal injury, death or major property
damage if ignored.

WARNING  warns about hazards that can

cause serious personal injury, death or major property
damage if ignored.

CAUTION  warns about hazards that will or

can cause minor personal injury or property damage if
ignored.
The word NOTICE indicates special instructions which
are important but not related to hazards.

1. To avoid risk of serious bodily injury and property

damage, read safety instructions carefully before
installing pump.

2. Follow local and/or national plumbing and electrical

codes when installing pump. A ground fault circuit
interrupter (GFCI) is recommended for use on any
electrical appliance submerged in water.

3. Use this pump only for backup sump pump duty in a

residential application. It is not designed as a primary
sump pump.

4.

Hazardous Voltage. Can cause severe or

fatal electrical shock. Do not plug in or unplug battery
charger while standing on a wet floor or in water. Be
sure one hand is free when plugging in or unplugging
charger. If basement floor is wet, disconnect power to
basement before walking on floor.

5. Do not lift pump by electrical cord.
6. Pump water only with this pump.
7. Do not run pump dry. To do so will damage seals and

can cause leaking and property damage.

8. Pump is permanently lubricated at the factory. Do not

try to lubricate it!

9. Keep battery charger and battery box in a dry, cool,

well ventilated area.

10. To avoid danger of fire or explosion, keep sparks and

flame away from battery.

11.

Battery acid is corrosive. Do not spill on

skin or clothing. Wear eye protection when working
on battery.

12. Maximum vertical pumping distance is 15 feet (4.6M).
13. Make sure sump is clear of debris.

2

CONTENTS

INTRODUCTION/WARRANTY.......................................2
SAFETY ...........................................................................2
PERFORMANCE..............................................................3
CHARGER OPERATIONS................................................3
BATTERY REQUIREMENTS .............................................4
INSTALLATION/OPERATION .........................................4
ELECTRICAL....................................................................5
SERVICE/TROUBLESHOOTING......................................6
PARTS.............................................................................7

INTRODUCTION

Please take a few minutes to read our instructions before
installing your Backup Sump Pump. It will help to assure
perfect installation and help you avoid needless service
expenses.

LIMITED WARRANTY

ALL PARTS .......................TWO (2) YEARS
ALL LABOUR .....................ONE (1) YEAR

Sears will repair or replace the pump free of charge if it fails due to manufacturing defects. 
Damage caused by improper installation is not covered by this warranty. 
This warranty is in addition to any statutory warranty.
For service return pump to the nearest Sears outlet.

SEARS CANADA INC. TORONTO M5B 2B8

RULES FOR SAFE INSTALLATION AND OPERATION

BASIC TOOLS AND MATERIALS NEEDED

Pipe Wrenches

Screwdriver

Hacksaw

1-1/4" Check Valve

Adjustable Wrench

Teflon Tape

Knife

12-volt Battery

Содержание CRAFTSMAN 572.826121

Страница 1: ...manual MODEL NO 572 826121 CAUTION Read all instructions carefully before starting the installation Save this Manual for future reference F642 9201 10 18 94 PRINTED IN U S A SEARS CANADA INC TORONTO...

Страница 2: ...ct power to basement before walking on floor 5 Do not lift pump by electrical cord 6 Pump water only with this pump 7 Do not run pump dry To do so will damage seals and can cause leaking and property...

Страница 3: ...charger will automatically re charge battery fully in about 6 hours If battery has not reached a satisfactory voltage after 24 hours of charging alarm will sound In this case alarm cannot be reset Pos...

Страница 4: ...w sufficient room for float switch to swing see Figure 1 4 Make sure that installation will not interfere with primary sump pump operation as follows A Backup pump installation must not interfere with...

Страница 5: ...If battery is fully charged green light CHARGED will be ON B If battery is being charged yellow light CHARG ING will be ON 4 When charger is plugged in battery is connected and unit is operating prop...

Страница 6: ...ounting block off of steel band Loosen screw in block and pull switch cord out of clamp Pull new switch cord through clamp and tighten screw Make sure tether length is the same as old switch s tether...

Страница 7: ...q PS17 43 Battery Case includes strap and strap brackets 7 PS17 58 Charger 8 PS22 1 Check Valve 9 Hose Clamp 1 min 2 max S S 10 PS78 3P Pipe Adapter 11 U78 846P Tee 1 1 2 x 1 1 2 x 1 1 4 PVC 12 U78 87...