background image

3

CONTENTS

Safety..................................................................................2

Warranty/Introduction .......................................................3

Installation.......................................................................4-8

Electrical........................................................................9-10

Operation .........................................................................11

Maintenance.....................................................................11

Service .........................................................................12-13

Troubleshooting ..........................................................14-15

Pump Performance ..........................................................15

Repair Parts .................................................................16-19

INTRODUCTION

We suggest you take a few minutes to read the instructions
contained in this manual before installing and using your
pump. This will help you obtain the full benefits of the qual-
ity and convenience built into this equipment. It will also
help you avoid any needless service expense resulting from
causes beyond our control which naturally cannot be cov-
ered in our warranty.

1. Read the Owners Manual and Rules for Safe Operation

and Installation Instructions carefully. Failure to follow
these Rules and Instructions could cause serious bodily
injury, and/or property damage.

2. Check your local electrical wiring codes before installa-

tion. If your local codes are not followed, your pump will
not work to its full rated capacity. If in doubt, contact
your local Power Company.

3. Be certain your pump installation meets all local plumb-

ing, pump and well codes.

4. While installing the pump, always keep the well covered

to prevent leaves and foreign matter from falling into the
well and contaminating the water and/or causing possi-
ble serious damage to the mechanical operation of the
pump.

5. Always test the well water for purity before using. Check

with local health department for testing procedure.

6. Before installing or servicing your pump, BE CERTAIN

pump power source is disconnected.

7. Be sure your pump electrical circuit is properly grounded.

8. Complete pump and piping system MUST be protected

against below freezing temperature. Failure to do so could
cause severe damage and voids the Warranty.

9. Make sure the line voltage and frequency of the electrical

circuit supply agree with the motor wiring. If motor is
dual voltage type, BE SURE it is wired correctly for your
power supply.

10. The correct fusing and wiring sizing is essential to proper

motor operation. Recommended fusing and wire size data
is in the manual.

THREE YEAR LIMITED WARRANTY

Provided that it is installed and operated according to the owner’s manual instructions, if this pump fails due to a 
defect in material or workmanship within one year from the date of purchase, it will be repaired or replaced free 
of charge.

During the second year and third year from purchase date, a free pump part will be supplied for a defective one. 
You must pay the labor cost if you wish to have it installed.

Warranty service is available by returning this product to place of purchase for replacement, or by calling 
1-800-4-MY-HOME

®

to arrange for part replacement or product repair.

This warranty is VOID if this pump is used for commercial or rental purposes.

Sears is not liable for loss or damage to property, nor for any incidental or consequential loss or expense from 
property damage, that results directly or indirectly from the use of this product.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179

RULES FOR SAFE INSTALLATION AND OPERATION

Содержание CRAFTMAN PROFESSIONAL HYDROGLASS 390.2519

Страница 1: ...tions Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A PROFESSIONAL HYDROGLASS CONVERTIBLE DEEP WELL JET PUMP Safety Instructi...

Страница 2: ...r r c ca au us se e d de ea at th h Ground pump before connecting to power supply H Ha az za ar rd do ou us s p pr re es ss su ur re e I In ns st ta al ll l p pr re es ss su ur re e r re el li ie ef f...

Страница 3: ...ource is disconnected 7 Be sure your pump electrical circuit is properly grounded 8 Complete pump and piping system MUST be protected against below freezing temperature Failure to do so could cause se...

Страница 4: ...1 1 4 PLASTIC PIPE CHECK VALVE AND STRAINER PLASTIC PIPE 1 1 PLASTIC PIPE PIPE ADAPTERS INSTALLATION DEEP WELL Figure 1 Captive Air Pressure Tank Installation Deep Well 1400 1194 JET WELL SEAL PLASTIC...

Страница 5: ...5 Figure 3 Captive Air Pressure Tank Installation Shallow Well Figure 4 Standard Pressure Tank Installation Shallow Well INSTALLATION SHALLOW WELL...

Страница 6: ...stance to the water level exceeds the suction lift of the pump Adjustment of the pressure regulator causes the right amount of water to be diverted back to the jet for the most efficient operation 1 L...

Страница 7: ...lete in well This serves to double check for leaks in piping and foot valve and simplifies final priming of pump INSTALLING CASING ADAPTER Slide adapter on to well casing as far as it will go Tighten...

Страница 8: ...er than the suction tapping of the pump Horizontal Offset Piping Sizes Shallow Well Jets 1 1 4 1 1 2 2 Up to 25 Ft 25 to 50 Ft 50 to 200 Ft Horizontal Offset Piping Sizes Deep Well Jets Up to 50 Ft 50...

Страница 9: ...the one at right Dial Type Voltage Selector To change to 115 volts 1 Make sure power is off 2 Turn the dial counter clockwise until 115 shows in the dial window 3 Reinstall the Motor end cover 4 Go t...

Страница 10: ...asing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the power supply wires to the pressure switch as shown in Figure 10 Figure 10 Pr...

Страница 11: ...ts pump and with faucets closed pressure will build up until pressure switch shuts off pump 8 There are certain conditions of deep well operation whereby the pressure regulator can be completely open...

Страница 12: ...haft Motor is now separated from pump see Figure 11 6 Lay back half of pump large surface down on a flat clean surface and tap out ceramic seat Clean seal cavity from which seal was removed and clean...

Страница 13: ...s not have to be dis connected 3 Withdraw jet assembly from well 4 Unscrew and remove the venturi Remove nozzle with a socket wrench if possible and clean If nozzle cannot be removed clean as explaine...

Страница 14: ...A deep well jet pump may be needed over 20 ft to water deliver water to full estimated capacity Also 2 Steel piping if used is corroded or 2 Replace with plastic pipe where possible otherwise with ne...

Страница 15: ...y ys st te em m S St to oc ck k N No o M Mo od de el l N No o H HP P 5 5 1 10 0 1 15 5 2 20 0 3 30 0 4 40 0 5 50 0 6 60 0 7 70 0 8 80 0 9 90 0 Shallow 29650 3 39 90 0 2 25 51 19 9 3 4 10 9 10 4 8 6 7...

Страница 16: ...1 2 x 9 x 1 4 7 U109 6A U109 6A Shaft Seal 8 J105 42PT J105 8PAN Impeller 9 J1 39P J1 40P Diffuser 10 U9 199 U9 199 O Ring Diffuser 1 7 8 x 1 5 8 x 1 8 11 C19 54SS C19 54SS Clamp Tank Body 12 L76 34P...

Страница 17: ...9 6 Clamp 3 U9 201 O Ring Venturi 4 N32P 63 Venturi Use with Model 390 2522 4 N32P 72E Venturi Use with Model 390 2519 5 J34P 41 51 Nozzle Use with Model 390 2522 5 J34P 44 54 Nozzle Use with Model 39...

Страница 18: ...29902 90 J32P 18 J34P 42 52 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 3 39 90 0 2 25 52 22 2 70 J32P 22 J34P 43 53 J40 25 J57 3 J43 16 J43 20C J161 3 J66 14 J216 14 90 J32P 18 J34P 42 52 J40 2...

Страница 19: ...asing Adapter 1 U30 282ZP U30 282ZP Machine Bolt 3 8 16 x 5 Lg 2 Req 2 J16 19ZZP J16 23ZZP Upper Flange 3 J21 19 J21 19 Seal Ring Drive Pipe 4 J21 18 J21 18 Seal Ring Suction Pipe 5 U30 277ZP U30 277Z...

Страница 20: ...ssional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Ho...

Отзывы: