D. MAGNETRON REMOVAL
(1) Disconnect the wire lead from the magnetron.
(2) Carefully remove the mounting screws holding the
magnetron and the waveguide.
(3) Remove the magnetron assembly until the tube is
clear from the waveguide.
NOTE:
1. When removing the magnetron, make sure its dome
does not hit any adjacent parts, or it may be damaged.
2. When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
3. After replacing the magnetron, check for microwave
leakage with a survey meter around the magnetron.
Microwave energy must be below the limit of 5
mW/cm2. (With a 275 ml. water load).
Make sure that gasket is rigidly attached to the
magnetron. To prevent microwave leakage, tighten
the mounting screws properly, making sure there is no
gap between the waveguide and the magnetron.
E. SUCTION GUIDE MAIN ASSEMBLY
NOTE: To repair any of them, the Suction Guide Main
ASS’Y should be removed first.
(1) Disconnect the wire lead from the high voltage
transformer primary terminal, thermostat, fuse holder,
and turn table motor connector.
(2) Remove three screws holding the Suction Guide Main
ASS’Y to oven cavity.
(3) Rotate right and pull out Suction Guide Main ASS’Y from
the oven.
Magnetron
Waveguide
Magnetron
Gasket
Magnetron
Dome
Waveguide
Bracket
Figures 11
Rotate right
and pull out
Pull out suction guide main ASS’Y
Screw
Remove screw
Figures 12
MODEL 721.69252990
721.69259990