-30-
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the unit)
Abnormal
Normal
Defective high
voltage
transformer.
Replace high
voltage
transformer.
Check high vol-
tage transformer
Normal
Normal
Abnormal
Defective high
voltage diode.
Replace high
voltage diode.
Check high vol-
tage diode
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check high vol-
tage capacitor
Abnormal
Defective
magnetron.
Replace
magnetron.
Check
magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run.
(Display operates properly)
NOTE : • Make sure the wire leads correct position.
• When Removing the wire leads from the parts, be sure to grasp the connector, not the wires.
• When removing the magnetron, be sure to install the magnetron gasket in the correct position
and in good condition.
Output is full power
when you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective PCB
assembly.
Replace PCB
assembly.
Содержание 721.66292500
Страница 9: ...6 OVERALL CIRCUIT DIAGRAM A SCHEMATIC DIAGRAM 8...
Страница 10: ...9 B MATRIX CIRCUIT FOR TOUCH KEY BOARD...
Страница 36: ...35 LATCH BOARD PARTS W102 5015 5006 4002 4003 4002 4004 4000 EV...
Страница 38: ...37 BASE PLATE PARTS 6000 6012 W108 6002 W109 W108 W101 6001 5008 EV...