WMP-SERIES INSTRUCTIONS

Seametrics • 253.872.0284 

Page 7 

seametrics.com

CONNECTIONS and OPERATION

Black:   Pin 4 = (–) Power

Blue:    Pin 3 = (+) Pulse

White:  Pin 2 = (–) Pulse

Brown: Pin 1 = (+) Power

Gray:    Pin  5  =  Ground

Shield Drain Wire

Cable Connections

Electrical Connections
WMP104.

  The  WMP104  is  battery-powered,  totally  self-

contained, and does not require any electrical connections 

(there is no output on the WMP104 model).

Operation

Grounding (WMP101).

 For best performance, especially 

in  chemically  noisy  environments,  the  gray  ground  wire 

and the bare drain wire should be connected together and 

to a good earth ground as close to the meter as possible. 

Metal  pipe  and  fittings  in  contact  with  the  fluid  should 

also be bonded to the same earth ground with corrosion-

resistant connections.

Display.

 The display reads flow rate and accumulated total, 

in the units for which it was ordered. The top line is the 

total, the bottom line is the rate, and indicators give the 

units (ac-ft, GPM for instance.) Empty or partially full pipe 

is automatically detected and is indicated by a reading of 

“ – EP – “.

Battery.

 The standard batteries are user replaceable 

with  an  approximate  1–2  year  life  depending  on  usage. 

An  extended  battery  life  option  offers  an  estimated  2–4 

year  life  depending  on  usage.  On  the  battery-powered 

WMP104 there is a low-battery indicator (“low bat”) when 

the battery voltage drops below a certain point. Batteries 

should be changed within four weeks of the appearance of 

this indicator.

WMP101.

 A connector is provided on the outside of the 

WMP101. To connect to the meter, plug the cable in and 

hand  tighten  the  retaining  threads.  Follow  the  diagram 

to  make  connections.  If  you  are  using  the  pulse  output, 

connect  power  first  and  determine  that  the  meter  is 

working properly by observing the display. Then connect 

the pulse output.

Grounding

Содержание WMP Series

Страница 1: ...PROUDLY MADE IN THE USA C e rtified Compa n y ISO 9001 2008 WMP Series Plastic Bodied Magmeter Instructions 2 inch 1 inch 3 inch...

Страница 2: ...ng is made of rugged powder coated diecast aluminum It can be fitted with cross drilled screws and seal wire for tamper evidence Flow rate and total can be displayed in a variety of units customer sel...

Страница 3: ...Million Gallons Day Cubic Feet Second Cubic Feet Minute Liters Second Liters Minute Million Liters Day Cubic Meters Minute Cubic Meters Hour Acre Feet Acre Inch Gallons Gallons x 1000 Cubic Feet Lite...

Страница 4: ...5 50 4 625 9 50 3 25 2 00 5 50 2 03 6 03 4 625 10 75 4 40 3 00 7 30 7 30 2 625 3 Inch Dimensions Dimensions shown without the Seametrics WMP Fitting Kit Flow Range 1 2 3 Gal Min Liter Sec Gal Min Lite...

Страница 5: ...P NOTE Above installation instructions are for WMP101 104 200 2 and WMP101 104 300 3 only The WMP101 104 100 1 is provided with integrated NPT female threaded ends INSTALLATION Piping Conditions It is...

Страница 6: ...lem Allows air pockets to form at sensor Better Installation Ensures full pipe Possible Problem Post valve cavitation can create air pocket Better Installation Keeps pipe full at sensor Air can be tra...

Страница 7: ...umulated total in the units for which it was ordered The top line is the total the bottom line is the rate and indicators give the units ac ft GPM for instance Empty or partially full pipe is automati...

Страница 8: ...efully unplug each of the two battery wiring harness connectors Slip the batteries out from under the elastic retainer and replace them with the new batteries Reconnect each of the two wiring harness...

Отзывы: