SL-PEL Series
Sectored Port Entry Light
Changing Battery Thresholds
Identify voltages to be changed. Type the new voltages below the current voltage settings and click
‘Write.’ The voltage threshold settings will change.
Disabling/Enabling Low Battery Voltage Options
If battery voltage falls below the low battery voltage threshold, three responsive actions may be selected:
• Reduce intensity down to 75% of the requirement
• Turn off the GPS
• Trigger the relay alarm
By default all the three options are enabled.
To
disable
any functionality, ensure the box to the left of the option is unchecked and click ‘Write.’
To
enable
any functionality, ensure the box to the left of the option is checked and click ‘Write.’
If battery voltage falls below the Flat Battery threshold, the PEL LEDs will power off. When the voltage
rises back above 12.0V the light will return to normal operation.
NOTE
: Remember to check the current operation mode as the PEL may require a certain light level to
return to expected intensity.
SEALITE DOES NOT RECOMMEND ADJUSTING BATTERY THRESHOLDS
Options disabled
Options enabled
!