![Sealite BargeSafe Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/sealite/bargesafe/bargesafe_installation-and-service-manual_1227814009.webp)
Latest products and information available at www.sealite.com
9
BargeSafe™ Solar 3nm LED Barge Light
COLREG-72 & UL 1104 Certified
Maintenance and Servicing
Designed to be maintenance free, the BargeSafe™ Solar 3nm requires minimal attention, though the
following maintenance and servicing information is provided to help ensure the life of your Sealite product.
1. Cleaning Solar Panels - occasional cleaning of the solar panels may be required. Using a cloth and
warm soapy water, wipe off any foreign matter before rinsing the panels with fresh water.
2. Battery Check - inspection of batteries should be performed every three years (minimum) to ensure
that the charger, battery and ancillary electronics are functioning correctly. Using a voltage meter,
check that the battery voltage is at least 12 volts under 100MA load, and ensure all terminals are clear
of foreign matter.
Replacing the battery
The has an internal battery compartment which provides the user with the ability to change the battery
after years of operation (see figure 2).
1. Remove the four socket-head screws on the top lens assembly and open.
2. Disconnect the positive and negative wires from the battery.
3. Remove battery retaining plate and lift battery from cradle.
4. Discard old battery in a safe manner.
5. Reattach positive and negative wires to the new battery.
6. Replace the battery into the cradle, and re-affix retaining plate with two wing-nuts and washers.
7. Replace the lens assembly back onto lantern housing ensuring that no wiring is protruding, and screw
four socket cap screws firmly. Ensure the o-ring seal is clean and clear from foreign matter.
8. To test place dark cover (towel or jacket) on top of light to activate sensor, light will come on.
Care must be taken to observe the polarity of each wire before they are connected. To ensure
waterproofing of the unit, make sure that no wires are protruding and that there is an even seal.
Always discard old batteries in a safe manner.
Long Term Battery Storage
If the BargeSafe™ Solar 3nm is to be placed in storage for an extended period please follow the below
information.
The sealed lead acid batteries inside the lights must always be stored in a fully charged state.
Always make sure the ON/OFF switch is in the OFF position.
If an ON/OFF switch is not fitted please disconnect the light head from the solar unit.
All batteries will discharge over time and the rate of discharge is dependent on temperature.
If the light is being stored in temperatures greater than 40
º
C the battery will discharge faster.
Please check battery regularly and recharge if necessary,
Either
Re-connect the light head and battery and place unit in the sun for 2-4 days
Or/
Re-connect light head and battery and place in front of a halogen lamp for 1-3 days.
(Do not place the
halogen light too close to the solar panel or the panel may be overheated)