Latest products and information available at www.sealite.com
21
Apollo-155
Long Range Lantern Adjustable from 4-12nm+
4.8 Light Sensor
For lanterns set to the “Dusk to Dawn” operation setting, the user may program specific ambient light
levels/Lux levels to suit their installation.
The ambient light threshold determines when the lantern will turn ON in the evening and OFF in the
morning.
To program the lantern Ambient Light Thresholds (see Image 6):
• Click the “Sensor” tab at the top of the Sealite Lantern Programmer
• From the “Light Sensor” box, type in the desired dusk & dawn thresholds
• Click the “Set Light Sensor” button to send the new setup instruction to the lantern
4.9 Battery Sensor
This feature enables the user to adjust the battery voltage thresholds of the lantern including:
Flat Battery
The lantern will automatically shut off when the battery voltage reaches the set threshold (lanterns are
factory set to 10v).
Low Battery
The lantern will automatically drop in intensity when the battery voltage reaches the set threshold (the
factory setting is disabled).
Recovery Threshold
The recovery threshold determines the voltage the battery must be re-charged to before the lantern
recovers from a “Low Battery” or “Flat Battery” condition (lanterns are factory set to 12v).
To program the lantern Battery Voltage Thresholds (see Image 6):
• Click the “Sensor” tab at the top of the Sealite Lantern Programmer
• From the “Battery Sensor” box, type in the desired flat, low & recovery battery thresholds (in volts)
• Click the “Set Battery Sensor” button to send the new setup instruction to the lantern
4.10 Temperature Sensor
The user may program the lantern to automatically reduce it’s intensity level when the internal lantern
temperature reaches a certain level.
To program the lantern Temperature Thresholds (see Image 6):
• Click the “Sensor” tab at the top of the Sealite Lantern Programmer
• From the “Temperature Sensor” box, type in the desired hot & recovery thresholds (in degrees
Celsius)
• Click the “Set Temperature Sensor” button to send the new setup instruction to the lantern