Sealey wps250a Скачать руководство пользователя страница 2

2.  INTRODUCTION & SPECIFICATIONS

3.  OPERATING INSTRUCTIONS

 

WARNING! Ensure you read, understand and apply safety instructions.

3.1.

   fit an appropriate discharge pipe to pump outlet and secure with a clip. Ensure the diameter of the discharge pipe is the same as, or   

 

greater than, the outlet diameter. A smaller pipe will adversely effect the pump flow rate. 

3.2.

 

Position the pump in the water and place the outlet pipe securely in the discharge receptacle or area. We recommend the pump is    

 

submerged with its discharge outlet facing up to release any trapped air.

3.3.

 

Plug the pump into the electrical mains supply and switch on.

 

The pump will automatically turn on as the level of water rises (fig.1.A). As water level lowers, the float will automatically switch the    

 

pump off as it reaches the minimum height (B). The float may be adjusted by shortening or lengthening the cable. The pump will  

 

 

switch on if the water level is up to or above the maximum length of the float cable. To function correctly the float must move freely.    

 

Ensure that the float can do so and that the cable is not restricted. check that the pump and discharge are working correctly.

3.4.

 

The water into which the pump is placed will act as the motor cooling agent. for this reason the pump must remain submerged at all   

 

times. Should the pump have to be used in shallow water 

DO NOT

 operate for more than 10 minutes. failure to follow this rule will    

 

damage the unit and will invalidate your warranty.

NOTE:

 See fig.2 to determine minimum clearance required if using the pump in a restricted area e.g:  a sump or well

fig.1

fig.2

Original Language Version

WPS250A    Issue: 1 - 22/01/14

 © Jack Sealey Limited

Manufactured from corrosion resistant materials with stainless steel body and motor case. fitted with automatic cut-out. Minimum water depth 

of 30mm. Designed for clean water although these pumps will accept small particles up to 5mm. Suitable for the effective drainage of cellars, 

sinks, cisterns, baths and the general transfer of water.

 

Model No:

 ........................................................................................................................................

WPS250A

 

cut-out: .............................................................................................................................................Automatic

 

outlet o/D ......................................................................................................................32mm (1"BSP )/24mm 

 

Maximum output: ...................................................................................................................250ltr(54gal)/min

 

Maximum Head: .........................................................................................................................................8mtr

 

Maximum running cycle (hr): ..................................................................................................................3 in 6

 

Motor Power:: .......................................................................................................................................... 600W

 Supply: ...................................................................................................................................................... 230V

Отзывы: