8
DO NOT
use extension cables.
9
Always disconnect from the mains supply before attempting any maintenance etc.
9
When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water an
d store in a frost free, safe
location.
WARNING! DO NOT
allow uncontrolled discharge of contaminated water which would pollute the environment.
2. INTRODUCTION
3. SPECIFICATION
Model no: ............................................................. WPCD215
Cut-out: .................................................................. Automatic
Outlet OD: .................................................................
Ø38mm
M
aximum Output/Min:
........................................
217L/(48gal)
Maximum Particle Size: .............................................
5/30mm
Maximum Head: ................................................................
8m
M
aximum Water Depth
...................................................... 7m
M
inimum Water Depth:
...................................................
5mm
Motor power: .................................................................
750W
Supply: ...........................................................................
230V
4. OPERATION
4.1.
INSTALLATION AND COMMISSIONING
4.1.1.
Attach a sufficiently long and strong rope to the handle
before first use. The pump is submerged into the liquid
on this holding rope and can also be carried with it as
well as the handle.
NOTE: DO NOT
suspend unit from the power cable.
NOTE:
With continuous use of the pump, the condition
of the rope must be regularly checked as it can decay
and break over time.
4.1.2.
Connect pressure pipe
4.1.2.1. For occasional use, use a suitable water hose.
4.1.2.2. The use of rigid pipes with a non return valve is
recommended for use at a fixed location. This prevents
return flow of liquid when switching off.
4.1.2.3.
Screw the pressure line onto the pressure connection.
4.1.2.4. All threaded connections must be sealed with thread
sealing tape.
4.1.2.5. When using a hose, screw a suitable hose adaptor onto
the pressure connection. Push the hose firmly onto the
hose adaptor and secure with a hose clamp.
4.1.3.
Installation
4.1.3.1. The pump needs an area of at least 50 x 50cm (the float switch must be able to move freely so that it functions properly.
4.1.3.2.
The pump can be submerged under water to the submerged operating depth of 7metres.
4.1.3.3. Install the pump so that the suction openings cannot be blocked by foreign bodies (place the appliance on a firm, even base if
necessary.
4.1.3.4.
Ensure that the pump is stable.
4.1.4.
Clear water mode Refer to fig.2A
4.1.5.
Fold the feet up to use the pump in clear water allowing suction up to 5mm from the ground and with particles in suspension that
are less than 5mm in diameter.
4.1.6.
Dirty water mode Refer to fig.2B
4.1.7.
Fold the feet down to use the pump in dirty water allowing suction up to 30mm from the ground and with particles in
suspension that are less than 30mm in diameter.
Manufactured from corrosion resistant materials with a polypropylene base cover. Features foldaway feet which convert the pumps’ usage
between clean and dirty water. With the feet extended out, the pump operates in dirty water up to a particle size of 30mm. With the feet folded
away, the pump operates in clean water up to a particle size of 5mm. Fitted with adjustable automatic cut-out. Minimum water depth of just 5mm.
Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general transfer of water and dense liquids.
Fig.1
Fig.2
Original Language Version
© Jack Sealey Limited
WPCD215 Issue 2 (3,F) 26/10/21