Sealey WPC100.V2 Скачать руководство пользователя страница 2

‰

8

‰

‰

DO NOt

 use to pump septic tanks or settling pits. 

DO NOt

 pump any liquids other than water.

‰

8

‰

‰

DO NOt

 operate the pump out of water. the pump pick up area must be completely submerged during operation.

‰

8

‰

‰

DO NOt

 exceed the maximum submersible depth (see specifications: max. suction Height). 

 

8

  

DO NOt

 operate the pump during freezing temperatures. 

DO NOt

 leave the pump in water that may freeze.

 

8

  

DO NOt

 use in swimming pools if people could come into contact with the water whilst pump is in use. 

 

8

  

DO NOt

 use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids. 

 

8

  

DO NOt

 carry the pump by its electrical cable, or its outlet pipe. use the handle only. 

 

9

  

When not in use, switch off pump and remove plug

 from power supply. rinse pump, drain out any water and store in a frost free, safe    

 location.

 

‰

 

 

warNiNG! DO NOt

 allow uncontrolled discharge of contaminated water which would pollute the environment.

 

note: this appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack  

 

of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person  

 

responsible for their safety. children should be supervised to ensure that they do not play with the appliance.

2.  iNtrODuCtiON

m

anufactured from corrosion resistant materials with stainless steel motor case and Noryl base cover. Minimum water depth of just 20mm. 

designed for clean water although these pumps will accept small particles up to 5mm. suitable for the effective drainage of cellars, sinks, cisterns, 

baths and the general transfer of water. The WPC100A.V2, WPC150A.V2, WPC235A.V2 and WPC250A feature an automatic low water cut-out. 

3.  speCiFiCatiON

4.  OperatiON

 

‰

  

warNiNG!

 ensure you read, understand and apply safety instructions.

4.1.    

fit appropriate discharge pipe to pump outlet and secure with clip. ensure the diameter of the discharge pipe is the same as or    

 

greater than the outlet diameter, as a smaller pipe will adversely effect the pump flow rate. 

4.2.    

Position the pump in the water accordingly, and place the outlet pipe securely in the discharge receptacle or area. it is recommended  

 

that the pump is sunk with its discharge outlet facing up, to release any trapped air.

4.3.    

connect the pump to the electrical mains supply and switch it on.

 

The automatic versions will automatically turn on as the level of water rises (fig.1.A). As the water level lowers, the float will  

 

 

automatically switch the pump off as it reaches the minimum height (fig.1.B). The float may be adjusted by shortening or lengthening  

 

the cable. The pump will switch on if the water level is up to or above the maximum length of the float cable. To function correctly the  

 

float must move freely. Ensure the float can do so and that the cable is not restricted. Check that the pump and discharge are working  

 correctly.

4.4.    

the water into which the pump is placed will act as the motor’s cooling agent. for this reason the pump must remain submerged at all  

 

times. should the pump have to be used in shallow water, 

DO NOt

 operate it for more than 10 minutes. Failure to follow this rule will  

 

damage the unit and will invalidate the warranty. 

 

NOTE: See fig.2 to determine minimum clearance required if using pump in a restricted area, i.e. a well, etc.

5.  maiNteNaNCe

 

‰

  

warNiNG!

 With the exception listed below, all pump, float and electrical cable service maintenance and repair must only be  

 

  undertaken by an authorised service agent. failure to observe this rule may be dangerous and will invalidate the warranty.

 

‰

  

warNiNG!

 ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.

4.1. 

Keep all parts of the pump clean. rinse, drain and allow to dry before storing the pump. 

model No. 

Cut-Out 

Outlet OD 

maximum  maximum  motor  input 

maximum 

minimum 

maximum  

 

 

 

Output 

Head 

  

 

particle size  water Depth  water Depth 

WPC100.V2 

Manual 

32mm 

100ltr/min 

6.0mtr 

250W  230V 

5mm 

20mm 

5mtr

WPC150.V2 

Manual 

32mm 

167ltr/min 

8.0mtr 

500W  230V 

5mm 

20mm 

7mtr

WPC235.V2 

Manual 

38mm 

208ltr/min 

8.5mtr 

750W  230V 

5mm 

20mm 

7mtr

WPC250 

Manual 

38mm 

250ltr/min 

9.5mtr 

900W  230V 

5mm 

20mm 

5mtr 

WPC100A.V2 

Automatic 

32mm 

100ltr/min 

6.0mtr 

250W  230V 

5mm 

20mm 

5mtr

WPC150A.V2 

Automatic 

32mm 

167ltr/min 

8.0mtr 

500W  230V 

5mm 

20mm 

7mtr

WPC235A.V2 

Automatic 

38mm 

208ltr/min 

8.5mtr 

750W  230V 

5mm 

20mm 

7mtr

WPC250A 

Automatic 

38mm 

250ltr/min 

9.5mtr 

900W  230V 

5mm 

20mm 

5mtr

fig.1

fig.2

Original Language Version

WPC100.V2, WPC100A.V2, WPC150.V2, WPC150A.V2, WPC235.V2, WPC235A.V2, WPC250, WPC250A    Issue: 3(L) - 25/10/17

 © Jack sealey limited

Содержание WPC100.V2

Страница 1: ... to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that repairs are carried out by a qualified electrician 1 1 5 Only allow the minimal amount of pump cable to enter water or wet areas The electrical cable is designed for use in water and must not be substituted If damaged contact a qualified electrician...

Страница 2: ... that the pump is sunk with its discharge outlet facing up to release any trapped air 4 3 Connect the pump to the electrical mains supply and switch it on The automatic versions will automatically turn on as the level of water rises fig 1 A As the water level lowers the float will automatically switch the pump off as it reaches the minimum height fig 1 B The float may be adjusted by shortening or ...

Страница 3: ...e is 12 months from purchase date proof of which is required for any claim 4 2 Regularly check the water inlet on the base of the pump to ensure that there are no blockages To access the impeller carefully undo the base hex headed screws and remove the base Clean the impeller and replace the base ensuring that the O ring is correctly located 8 8 DO NOT dismantle any other part of the unit 6 troubl...

Страница 4: ...ned Date Name Position Place Bury St Edmunds Submersible Water Pump 230V 100ltr min 167ltr min 208ltr min 250ltr min A Automatic 2014 30 EU EMC Directive 2014 35 EU Low Voltage Directive 2011 65 EU RoHS Directive References to harmonised standard s EN 55014 1 2006 A1 A2 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 60335 1 2012 A11 EN 60335 2 41 2003 A1 A2 EN 62233 2008 4 August 2017 Stev...

Страница 5: ...E It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump 100ltr min 230V Model No WPC100 V2 ...

Страница 6: ...SHEATH 6 WPC250 06 CABLE PLUG 7 WP05602005 CABLE BUCKLE 8 WPC100V2 08 CAPACITOR 4uF 9 WP05501001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 ALUMINUM REAR COVER 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC100V2 14 ROTOR 15 WPC100V2 15 STATOR 16 WPC250 16 BUSHING 17 WP03802023 WASHER 18 WPC100V2 18 SEAL 19 WP04204001 ALUMINUM BUSHING 20 WPC100V2 20 O RING 21 WPC100V2 21...

Страница 7: ...s our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump Automatic 100ltr min 230V Model No WPC100A V2 ...

Страница 8: ...0V2 08 CAPACITOR 4uF 9 WP05501001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 ALUMINUM REAR COVER 11 1 WP05202003 WIRE SHEATH 11 2 WPC100V2 11 2 WASHER 11 3 WP08601010 WIRE GREEN YELLOW 11 4 WP04102006 PLATE 11 5 WPC100V2 11 5 WASHER 11 6 WP818 SCREW M4X8 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC100V2 14 ROTOR 15 WPC100V2 15 STATOR 16 WPC250 16 BUSHING 17 WP03802023...

Страница 9: ... It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump 167ltr min 230V Model No WPC150 V2 ...

Страница 10: ...001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 ALUMINUM REAR COVER 11 1 WP05202003 WIRE SHEATH 11 2 WPC150V2 11 2 WASHER 11 3 WP08601010 WIRE GREEN YELLOW 11 4 WP04102006 PLATE 11 5 WPC150V2 11 5 WASHER 11 6 WP818 SCREW M4X8 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC150V2 14 ROTOR 15 WPC150V2 15 STATOR 16 WPC235V2 16 BUSHING 17 WP03802023 WASHER 18 WPC150V2 18 SEAL ...

Страница 11: ...is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump Automatic 167ltr min 230V Model No WPC150A V2 ...

Страница 12: ...C150V2 08 CAPACITOR 8uF 9 WP05501001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 COVER 11 1 WP05202003 CABLE SHEATH 11 2 WPC150V2 11 2 WASHER 11 3 WP08601010 YELLOW GREEN WIRE 11 4 WP04102006 WIRE CONNECTING PAD 11 5 WPC150V2 11 5 WASHER 11 6 WP818 SCREW M4X8 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC150V2 14 ROTOR 15 WPC150V2 15 STATOR 16 WPC235V2 16 BUSHING 17 WP03...

Страница 13: ... It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump 208ltr min 230V Model No WPC235 V2 ...

Страница 14: ...1001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 ALUMINUM REAR COVER 11 1 WP05202003 WIRE SHEATH 11 2 WPC235V2 11 2 WASHER 11 3 WP08601010 WIRE GREEN YELLOW 11 4 WP04102006 PLATE 11 5 WPC235V2 11 5 WASHER 11 5 WP818 SCREW M4X8 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC235V2 14 ROTOR 15 WPC235V2 15 STATOR 16 WPC235V2 16 BUSHING 17 WP03802023 WASHER 18 WPC235V2 18 SEAL...

Страница 15: ...is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump Automatic 208ltr min 230V Model No WPC235A V2 ...

Страница 16: ... CAPACITOR 8uF 9 WP05501001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 ALUMINUM REAR COVER 11 1 WP05202003 WIRE SHEATH 11 2 WPC235V2 11 2 WASHER 11 3 WP08601010 YELLOW GREEN WIRE 11 4 WP04102006 WIRE CONNECTING PAD 11 5 WPC235V2 11 5 WASHER 11 6 WP818 SCREW M4X8 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC235V2 14 ROTOR 15 WPC235V2 15 STATOR 16 WPC235V2 16 BUSHING 17 ...

Страница 17: ...E It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump 250ltr min 230V Model No WPC250 ...

Страница 18: ...P05501001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 ALUMINUM REAR COVER 11 1 WP05202003 WIRE SHEATH 11 2 WPC250 11 2 WASHER 11 3 WP08601010 WIRE 11 4 WP04102006 PLATE 11 5 WPC250 11 5 WASHER 11 6 WP818 SCREW M4X8 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC250 14 ROTOR 15 WPC250 15 STATOR 16 WPC250 16 BUSHING 17 WP03802023 WASHER 18 WPC250 18 SEAL Item Part No Descri...

Страница 19: ...is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for incorrect use of product WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Information Submersible Water Pump Automatic 250ltr min 230V Model No WPC250A ...

Страница 20: ...F 9 WP05501001 CABLE GRIP 10 WP07802018 SELF TAPPING SCREW 11 WP02602004 ALUMINUM REAR COVER 11 1 WP05202003 WIRE SHEATH 11 2 WPC250 11 2 WASHER 11 3 WP08601010 WIRE 11 4 WP04102006 PLATE 11 5 WPC250 11 5 WASHER 11 6 WP818 SCREW M4X8 12 WP03801001 WAVE WASHER 13 B 6201ZZ BEARING 6201ZZ 14 WPC250 14 ROTOR 15 WPC250 15 STATOR 16 WPC250 16 BUSHING 17 WP03802023 WASHER 18 WPC250 18 SEAL Item Part No D...

Отзывы: