background image

3. 

SpecIfIcAtIOn

model number:

 ...........................................................

tA310

captured conductor size:................ ........... Ø8mm maximum

low Battery indicator:...................... .........................led red 

operating temperature:................... .................. 0°c to 50°c.

storage temperature:...................... ...............-15°c to 50°c.

Battery type:.................................... ............................9V dc

typical Battery life:......................... ...............80hrs (alkaline)

Weight:............................................. .............................. 240g

dimensions (H X W X d):................ 190mm x 70mm x 38mm

output connection:...................... Banana plugs (red & black)

Effective Measurement Range

20A (output: 100mV/A=1mV/10mA): <2A use dc or rms Ac for

200mV range of the multimeter, >2A use dc or rms Ac for 2V 

range of the multimeter.

80A (output: 10mV/A): dc or rms Ac for 200mV range of the multimeter.

 

Accuracy

dcA range: 10mA~20A

(output: 100mV/A=1mV/10mA)    ± (3% ±5mA)

dc range: 100mA~80A                100mA~40A ± (3% ±0.3A)

(output: 1mV/A)                            40A~80A      ± (4% ±0.3A)

AcA range: 10mA~20A  (output: 100mAV/A= 1mV/10mA) 

10mA~20A (40Hz~2kHz)  

± (3% ±5mA)

10mA~20A (2kHz~10kHz)  

± (4% ±30mA)

10mA~20A (10kHz~20kHz)   ± (6% ±30mA)

10A~20A (40Hz~20kHz)  

± (8% ±30mA)

Ac range 100mA~80A (output: 1mV/A)

100mA~80A (40Hz~2kHz)  

± (8% ±30mA) 

100mA~80A (1kHz~2kHz)  

± (4% ±30mA)

100mA~80A (3kHz~5kHz) 

± (6% ±30mA) 

40A~80A (40Hz~5kHz)  

± (8% ±0.30A)

load resistance: 10

Ώ

 typical

Original Language Version

© Jack sealey limited

model number:...............................tA311 

captured conductor size:................Ø20mm maximum

low Battery indicator:...................... led red 

operating temperature:................... 0°c to 50°c.

storage temperature:...................... -15°c to 50°c.

Battery type:....................................9V dc

typical Battery life:..........................80hrs (alkaline)

Weight:.............................................240g

dimensions (H X W X d):................175mm x 70mm x 38mm

output connection:..........................Banana plugs (red & black)

Effective Measurement Range

40A (output: 10mV/A): dc or rms Ac for 200mV or 400mV

range of the multimeter.

400A (output: 1mV/A): dc or rms Ac for 400mV range of the

multimeter.

 

Accuracy

dcA range: 40A

0~20.00Adc: 

± (3.5% + 6 digits)

20.00~40.00Adc: 

± (4% + 10 digits)

dc range: 400A

0~300.0Adc: 

± (3.5% + 10 digits)

300.0~400.0Adc: 

± (4.5% + 10 digits)

AcA range: 40A (50Hz/60Hz)

0~20.00AAc: 

± (4.0% + 10 digits)

20.00~40.00AAc: 

± (5.0% + 10 digits)

AcA range: 400A (50Hz/60Hz) 

0~300.0AAc: 

± (4.5% + 10 digits)

300.0~400.0AAc: 

± (5.0% + 10 digits)

fig.2

tA311

Power on

green led

low battery

red led

dc measuring

zero button

Power and 

range switch

Black (-)

red (+)

depress trigger to open

spring return jaws

tA310

tA310, tA311  issue 2 (H, 1, 4, f) 05/12/17