background image

Digital automotive analyser 

14 function WitH inDuctive coupler

Model no: 

ta303

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  safety

1.1.    

personal  precautions

 

9

   When using this analyser, please observe all normal safety rules concerning

:

 

 

Protection against the dangers of electric current.

 

 

Protection of the analyser against misuse.

 

9

   Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced  

  with genuine Sealey leads with the same electronic ratings. Failure to do so will invalidate the warranty.

 

8

  

Do not

 use leads if damaged or if the wire is bared in any way. 

1.2.    

general safety instructions

 

9

   Familiarise yourself with the application and limitations of the analyser as well as the potential hazards. 

if in any DouBt consult a  

  QualifieD electrician.

 

9

   Before commencing testing, follow instructions below and select the correct input sockets, function and range on the analyser.

 

9

   When the analyser is connected to a circuit, 

Do not

 touch any unused analyser terminals.

 

9

   When the magnitude of the value to be measured is unknown beforehand, set the range selector to the highest value available.

 

9

   Before rotating the range selector to change functions, disconnect test probes from the circuit under test.

 

‰

   Warning! 

Never perform resistance, transistor, diode or continuity measurements on live circuits.

 

9

   Always take care when working with voltages above 35V dC or 25V AC rms. These voltages are considered a shock hazard. 

 

‰

  

Warning! use eXtreme caution

 when working with high voltages.

 

9

   Always keep fingers behind the probe barriers whilst measuring, and 

Do not

 use when hands are wet..

 

9

   Before attempting to insert transistors for testing, ensure that the test leads have been disconnected.

 

9

   Components should not be connected to the transistor socket when taking voltage measurements with the test leads.

 

8

  

Do not

 test voltages above 600V AC or dC - the circuitry of the analyser will be destroyed.

 

‰

  

Warning! never

 connect the analyser to a voltage source / live circuit when the rotary switch is set to any other function apart from  

  Voltage testing.

 

9

  

alWays

 discharge filter capacitors in power supplies and disconnect the power when making resistance or diode tests.

 

‰

  

Warning! 

Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed  

  electrical contacts. other means should be used to ensure that the terminals are not “live”.

 

8

  

Do not

 use the analyser in a potentially explosive atmosphere or where flammable material is present.

 

9

  

only

 operate the analyser when the back cover is in place and fastened securely.

 

9

   If any abnormal readings are observed, the analyser must be checked out by an authorised technician.

 

9

  

alWays

 turn off the analyser and disconnect the test leads, before opening the back cover to replace the fuse or battery.

 

9

   When not in use, store the analyser carefully in a safe, dry, childproof location out of direct sunlight. If storing for a long period of time,  

  remove the battery. Storage temperature range: -20°C to 60°C. 

note:

 

The warnings, cautions and instructions referred to in this manual cannot cover all possible conditions and situations that may occur. It  

 

 

must be understood that common sense and caution are factors which cannot be built into this product, but must be applied by the   

  operator.

2.  introDuction

new generation 14-function, auto-ranging automotive diagnostic multimeter. Combination digital/bar-graph display gives accurate 

indication of component outputs. large, easy to read high contrast display with bright, white backlight. Workshop-tough, durable 

bi-composite case with integral stand and auto power shut-off. 

High speed processing circuitry reads standard automotive parameters including duty cycle and pulse width making this tool 

ideal for testing fuel injection systems. Features auto-ranging, and data hold functions with overload protection on all ranges. 

Includes relative functions including Max/Min and Peak/Hold. Supplied with inductive coupler, test probes and thermocouple.

TA303 Issue 2 (HF) 03/10/18

Original Language Version

© Jack Sealey limited

Refer to 

instructions

electrical shock 

hazard

 Warning

Содержание TA303

Страница 1: ... disconnected 9 9 Components should not be connected to the transistor socket when taking voltage measurements with the test leads 8 8 DO NOT test voltages above 600V AC or DC the circuitry of the analyser will be destroyed WARNING NEVER connect the analyser to a voltage source live circuit when the rotary switch is set to any other function apart from Voltage testing 9 9 ALWAYS discharge filter c...

Страница 2: ...ble Insulation Overvoltage category CAT III 1000V CAT IV 600V Display 4000 counts LCD display with function indication Polarity Automatic negative polarity indication Over range OL marks indication Low battery indication BAT is displayed when the battery voltage drops below the operating level Measurement rate 2 times per second nominal Auto power off Analyser automatically shuts down after approx...

Страница 3: ...f reading 7 digits 40nF 10pF 5 0 of reading 7 digits 400nF 0 1nF 4uF 1nF 3 0 of reading 5 digits 40uF 10nF 400uF 0 1uF 4mF 0 001mF 10 0 of reading 10 digits 40mF 00 01mF Capacitance Auto Ranging Range Resolution Accuracy 400 0Ω 0 1Ω 1 2 of reading 4 digits 4 000kΩ 1Ω 1 0 of reading 2 digits 40 00kΩ 10Ω 1 2 of reading 2 digits 400 0kΩ 100Ω 4 000MΩ 1kΩ 40 00MΩ 10kΩ 2 0 of reading 3 digits Resistance...

Страница 4: ... test probes to the circuit under test black test probe to earth or negative terminal and read the voltage displayed Note IMPORTANT Voltage must be measured in parallel Red probe measuring circuit from power source WARNING When measuring voltage be sure that the red test lead is in the jack marked VΩHz etc If the red test lead is in the 20A or 400mA jack the user may be injured or the analyser dam...

Страница 5: ... negative COM jack and the red test lead into the positive VΩHz etc jack 4 16 2 Turn the rotary switch to the ms PULSE position 4 16 3 Press the range button until the negative trigger slope is displayed on the right of the display Note The applied time for most fuel injectors is displayed on the negative slope 4 16 4 Connect jumper wires between the fuel injector and the harness connector 4 16 5 ...

Страница 6: ...amic type for the 400mA range 5 5 4 Replace the rear cover and secure with the six screws WARNING To avoid electric shock DO NOT use the analyser until it has been fully re assembled 6 Parts Item Part No Description 1 TA302 01 TEMPERATURE PROBE 2 TA302 02 Inductive pick up 3 TA302 03 TEST LEADS 4 TA302 04 WATER PLUG TA303 Issue 2 HF 03 10 18 Original Language Version Jack Sealey Limited Sealey Gro...

Отзывы: