Voltage  . . . . . . . . . . . . . .(V AC/DC)

Resistance . . . . . . . . . . . .(

Ω)

Diode Check  . . . . . . . . . .(     )

Audible Continuity  . . . . . .(    )

AC or DC Current  . . . . . .(A)

Temperature . . . . . . . . . . .(Temp °C & °F)

Frequency  . . . . . . . . . . . .(Freq)

Dwell  . . . . . . . . . . . . . . . .(      )

Duty Cycle  . . . . . . . . . . . .(%)

Ms - Pulse & ms - Period  .(ms)

RPM  . . . . . . . . . . . . . . . .(       )

1.1.

PERSONAL PRECAUTIONS

!

When using this meter, please observe all normal safety rules concerning

:

Protection against the dangers of electric current.
Protection of the meter against misuse.

!

Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced with genuine Sealey
leads with the same electronic ratings. Failure to do so will invalidate the warranty.

"

DO NOT

use leads if damaged or if the wire is bared in any way. 

1.2. GENERAL SAFETY INSTRUCTIONS

!

Familiarise yourself with the application and limitations of the meter as well as the potential hazards. 

IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.

!

When the meter is linked to a measurement circuit, do not touch unused meter terminals.

!

When the scale of the value to be measured is unknown set the selector to the highest range available.

!

Before rotating the range selector to change functions, disconnect test leads from the circuit under test.

#

WARNING! 

Never perform resistance measurements on live circuits.

!

Always be careful when working with voltages above 60Vdc or 30Vac rms. Keep your fingers behind the probe barriers while measuring.

!

When not in use, store the meter carefully in a safe, dry, childproof location. Storage temperature range -10

O

C to 50

O

C.

!

Never apply voltage or current to the meter that exceeds the specified maximum.

Layout: 

( Refer to fig. 1. )

1. 

Large LCD display

2. Max/Min/RS232 

Button

3. 

Relative  Button

4. 

Data Hold/Back Light Button

5. 

Rotary selector Switch

6.

Volts

Ω, 

Hz, %, RPM, CAP, ms,

DWELL and TEMP Terminal

7. 

Com

Terminal

8. 

mA

Terminal

9. 

20A

Terminal

10. Range/#CYL Button
11.

± TRIG Button

12.

Mode/RPM, 2, 4 stroke Button

INSTRUCTIONS FOR: 

DIGITAL AUTOMOTIVE ANALYSER 15

FUNCTION BAR GRAPH/PC LINK 

MODEL:TA203.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,
give you years of trouble free performance.

1.

SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

2.

FEATURES

Input Limits

Function

Maximum Input

AC Volts

750V AC rms

20A AC/DC (30 secs
max every 15 minutes)

250V AC/DC

250V AC/DC

250V AC/DC

Extra large, hi-contrast LCD display with 36mm high digital read-out, bar graph and backlight. Durable bi-composite case with probe storage and integral
stand, suitable for the toughest workshop conditions. Features millisecond pulse-width function for accurate measurement of fuel injection systems.
Includes auto ranging, data hold and auto power off. Supplied with inductive coupler with adjustable sensitivity, for fast reading of engine rpm, test leads
(probe and clip) and thermocouple plus interface cable and software for downloading data to PC.

Meter Functions

FIG. 1.

Terminal

V - 

Ω 

- RPM

V - 

Ω 

- RPM

V - 

Ω 

- RPM

V - 

Ω 

- RPM

Frequency

Ohms (Resistance)

Diode Test

AC/DCµ AmA

µ A/mA

400mAAC/DC

20A

20AAC/DC

RPM

Duty Cycle (%)

Dwell Angle

#  

WARNING! Do Not make current measurements on the 20A
scale for longer than 30 seconds in every 15 minutes. 
Exceeding 30 seconds may cause damage to the meter and 
test leads.

#  

WARNING! Ohms can not be measured if a voltage is present.
Only measure in non powered circuits.

1000V DC

DC Volts

Fig.2

TA203.V2 - 1 - 200807

Содержание TA203.V2

Страница 1: ...om Terminal 8 mA Terminal 9 20A Terminal 10 Range CYL Button 11 TRIG Button 12 Mode RPM 2 4 stroke Button INSTRUCTIONS FOR DIGITAL AUTOMOTIVE ANALYSER 15 FUNCTION BAR GRAPH PC LINK MODEL TA203 V2 Thank you for purchasing a Sealey product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years of trouble free performance 1 SAF...

Страница 2: ...eading 7 digits DC Voltage Auto Ranging AC Voltage Auto Ranging except 400mV Input Impedance 10MΩ Maximum Input 700Vac rms or 1000Vdc DC Current Auto Ranging for uA and mA Input Impedance 10MΩ Frequency Range 50 to 400Hz Maximum Input 750Vac rms or 100Vdc Overload Protection 0 5A 250V and 20A 250V Fuse Maximum Input 400mAac rms or 400mAdc on uA mA ranges 20A ac rms or dc on 10A range AC Current Au...

Страница 3: ...h or unstable Note The Trigger level has five steps and is different for each function combination 4 6 MAX MIN RS232 fig 1 2 4 6 1 Press the MAX MIN to enter MAX MIN mode Note MAX MIN function is only available in the manual range 4 6 2 Select the proper test range before activating the MIN MAX button to ensure that the MIN MAX reading will not exceed the testing range 4 6 3 Press once to select M...

Страница 4: ...as an adjustable sensitivity switch that may also be used to correct an unstable reading 4 16 Dwell Angle Measurement Dwell angle is the number of degrees through which the distributor cam rotates while the breaker points are closed 4 16 1 Insert the black test lead into the negative COM jack and the red test lead into the positive V jack 4 16 2 Turn the rotary switch to the dwell position 4 16 3 ...

Страница 5: ...nd the same on the following screen The program will be installed when done click Finished 4 18 7 To run the program go to All programs within the Start menu and find 9995 and select 9995 exe 4 18 8 Click button A FIG 5 to toggle between available COM ports until the COM in window B FIG 5 matches the number found in the device manager in step 4 18 5 fig 5 The program is now ready to capture data f...

Страница 6: ...tion Parts 1 TA203 V2 01 TEMPERATURE PROBE 2 TA203 V2 02 TEST LEADS 3 TA203 V2 03 CROCODILE CLIPS 4 TA203 V2 04 HOLSTER 5 TA203 V2 05 CABLE USB 6 TA203 V2 06 INDUCTIVE PICK UP 7 TA203 V2 07 CARRY CASE NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for inc...

Отзывы: