Overvoltage Category

:

CAT.111. 1000V.

RS232

: Optically isolated PC interface cable and Windows® 95/98/200/XP compatible software to collect, display, plot and save data.

Display

: 4 3.4 digit (4000 counts) LCD display with function and unit sign annunciator.

Analogue Bar Graph

: 40 segments with measurements 15 times per second.

Polarity: 

Automatic, (-) negative polarity indication.

Over Range Indication

: “OL” mark indication.

Low Battery Indication

: The         is displayed when the battery voltage drops below the operating level.

Auto Power Off

: Meter automatically shuts down after approx. 30 minutes of inactivity.

Measurement Rate

: 2 times per second, nominal.

Operating Environment

: 0°C to 50°C (32°F to 122°F) at <70% relative humidity.

Storage Environment

: -20°C to 60°C (14°F to 140°F) at <80% relative humidity.

Temperature Coefficient

: 0.2 x (specified accuracy) / °C (< 18°C or > 28°C.

Power

: Single standard 9 Vollt battery ( PP9 ).

Battery Life

: 200 hours typical with alkaline battery.

Fuse

: 20A/250V, 10.3 x 38mm fast acting ceramic type.

0.5A/250V, 5 x 20mm fast acting ceramic type.

Dimensions

: 197 (H) x 88.4 (W) x 41.2 (D) mm.

Weight Approx

: 635g including holster.

Accuracy is given at 18°C to 28°C (65°F to 83°F) less than 70% relative humidity.

3.

SPECIFICATION

Range

Resolution

Accuracy

400.0mV

0.1mV

± 0.5% of reading ± 2 digits

4.000V

1mV

40.00V

10mV

±1.5% of reading ± 2 digits

400.0V

100mV

1000V

1V

± 1.8% of reading ± 2 digits

Range

Resolution

Accuracy

400.0mV

0.1mV

± 1.5% of reading ± 60 dig

4.000V

1mV

± 1.0% of reading ± 3 digits

40.00V

10mV

± 1.5% of reading ± 3 digits

400.0V

100mV

750V

1V

± 2.0% of reading ± 4 digits

Range

Resolution

Accuracy

400.0uA

0.1uA

± 1.0% of reading ± 3 digits

4000uA

1uA

40.00mA

10uA

± 1.5% of reading ± 3 digits

400.0mA

100uA

4A

1mA

± 2.5% of reading ± 5 digits

20A

10mA

Range

Resolution

Accuracy

400.0

0.1

± 1.2% of reading ± 4 digits

4.000k

1

± 1.0% of reading ± 2 digits

40.00k

10

± 1.2% of reading ± 2 digits

400.0k

100Ω

4.000M

1k

40.00M

10k

± 2.0% of reading ± 3 digits

Range

Resolution

Accuracy

400.0uA

0.1uA

± 1.5% of reading ± 5 digits

4000uA

1uA

40.00mA

10uA

400.0mA

100uA

4A

1mA

± 3.0% of reading ± 7 digits

20A

10mA

± 2.5% of reading ± 7 digits

DC Voltage 

(Auto Ranging)

AC Voltage

(Auto Ranging except 400mV)

Input Impedance: 10M

Ω.

Maximum Input 700Vac rms or 1000Vdc. 

DC Current

(Auto Ranging for uA and mA)

Input Impedance: 10M

Ω.

Frequency Range: 50 to 400Hz.
Maximum Input: 750Vac rms or 100Vdc.

Overload Protection: 0.5A/250V and 20A/250V Fuse. 
Maximum Input:400mAac rms or 400mAdc on uA/mA ranges
20A ac rms or dc on 10A range.

AC Current

(Auto Ranging for uA and mA

Overload Protection: 0.5A/250V and 20A/250V Fuse.
Frequency Range:50  to 400Hz
Maximum Input: 40mA ac rms or 400mA dc on uA/mA ranges,
20A ac rms  or dc on 20A range.

Resistance 

(Auto Ranging)

Range

Resolution

Accuracy

40.00nF

10pF

± 5.0% of reading ± 7 digits

400.0nF

0.1nF

4.000uF

1nF

± 3.0% of reading ± 5 digits

40.00uF

10nF

100.0uF

0.1uF

± 5.0% of reading ± 5 digits

Capacitance

(Auto Ranging)

Input Protection: 250Vac rms or 250Vdc.

Input Protection: 250Vac rms or 250Vdc.

Range

Resolution

Accuracy

5Hz

0.001Hz

50Hz

0.01Hz

± 1.5% of reading ± 5 digits

500Hz

0.1Hz

5kHz

1Hz

30.00kHz

10Hz

± 1.2% of reading ± 3 digits

Frequency

(Auto Ranging)

Sensitivity: >5V RMS MIN.
Overload Protection: 250Vac rms or dc.

Range

Resolution

Accuracy

0.1%~99.9%

0.1%

± 1.2% of reading ± 4 digits 

Duty Cycle

(Auto Ranging)

Pulse Width: >100us, <100ms
Sensitivity: < 0.5V rms
Overload Protection: 250Vac rms or dc. 

Range

Resolution

Accuracy

2.0~10.0ms

0.1ms

± 3% of reading ± 10 digits

Pulse Width

Overload Protection: 250Vac rms or dc.

Range

Resolution

Accuracy

-20°C~+760°C 1°C

± 3.0% of reading ± 5 digits

-4°F~+1400°F

1°F

(Meter only, probe accuracy 
not included).

Range

Resolution Accuracy

RPM 4 600~4000RPM

1RPM

600~1200RPM

10RPM

(X 10PM)

±2% of rdg ± 4 digits

RPM 2 300~4000 RPM

1RPM

300~600RPM

10RPM

(x 10RPM)

Temperature

Sensor: Type K Thermocouple

Range

Resolution

Accuracy

0.3mA typical

1mV

± 10% of reading ±5 digits

Diode test

Open Circuit Voltage: 1.5Vdc typical
Overload Protection: 250Vac rms or dc. 

Cylinder Range

Resolution

Accuracy

1CYL

0~360.0°

2CYL

0~180.0°

3CYL

0~120.0°

4CYL

0~90.0°

5CYL

0~72.0°

0.1°

± 2.0% of reading ± 4 digits

6CYL

0~60.0°

8CYL

0~45.0°

10CYL

0~36.0°

12CYL

0~30.0°

Dwell Angle

Overload Protection: 250Vac rms or dc. 

Effect Reading: >600RPM
Overload Protection: 250Vac rms or dc.

RPM 

(Tach)

Audible Continuity

Audible threshold:

Less than 150

Test Current:

<0.3mA

Overload Protection:

250Vac rms  or dc.

TA203.V2 - 1 - 200807

Содержание TA203.V2

Страница 1: ...om Terminal 8 mA Terminal 9 20A Terminal 10 Range CYL Button 11 TRIG Button 12 Mode RPM 2 4 stroke Button INSTRUCTIONS FOR DIGITAL AUTOMOTIVE ANALYSER 15 FUNCTION BAR GRAPH PC LINK MODEL TA203 V2 Thank you for purchasing a Sealey product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years of trouble free performance 1 SAF...

Страница 2: ...eading 7 digits DC Voltage Auto Ranging AC Voltage Auto Ranging except 400mV Input Impedance 10MΩ Maximum Input 700Vac rms or 1000Vdc DC Current Auto Ranging for uA and mA Input Impedance 10MΩ Frequency Range 50 to 400Hz Maximum Input 750Vac rms or 100Vdc Overload Protection 0 5A 250V and 20A 250V Fuse Maximum Input 400mAac rms or 400mAdc on uA mA ranges 20A ac rms or dc on 10A range AC Current Au...

Страница 3: ...h or unstable Note The Trigger level has five steps and is different for each function combination 4 6 MAX MIN RS232 fig 1 2 4 6 1 Press the MAX MIN to enter MAX MIN mode Note MAX MIN function is only available in the manual range 4 6 2 Select the proper test range before activating the MIN MAX button to ensure that the MIN MAX reading will not exceed the testing range 4 6 3 Press once to select M...

Страница 4: ...as an adjustable sensitivity switch that may also be used to correct an unstable reading 4 16 Dwell Angle Measurement Dwell angle is the number of degrees through which the distributor cam rotates while the breaker points are closed 4 16 1 Insert the black test lead into the negative COM jack and the red test lead into the positive V jack 4 16 2 Turn the rotary switch to the dwell position 4 16 3 ...

Страница 5: ...nd the same on the following screen The program will be installed when done click Finished 4 18 7 To run the program go to All programs within the Start menu and find 9995 and select 9995 exe 4 18 8 Click button A FIG 5 to toggle between available COM ports until the COM in window B FIG 5 matches the number found in the device manager in step 4 18 5 fig 5 The program is now ready to capture data f...

Страница 6: ...tion Parts 1 TA203 V2 01 TEMPERATURE PROBE 2 TA203 V2 02 TEST LEADS 3 TA203 V2 03 CROCODILE CLIPS 4 TA203 V2 04 HOLSTER 5 TA203 V2 05 CABLE USB 6 TA203 V2 06 INDUCTIVE PICK UP 7 TA203 V2 07 CARRY CASE NOTE It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice IMPORTANT No liability is accepted for inc...

Отзывы: