Sealey SSP80PAPR Скачать руководство пользователя страница 4

4.9.5.   TO 

STOP

4.9.6. 

  

Press the ON/OFF button (

fi

 g 6 - 1) for approx one second, until the audible alarm and blower stops.

 

  

WARNING!

 If the danger indicator light (

fi

 g 6 - 4) comes on, the audible alarm sounds and the blower (

fi

 g 6 - 6) vibrates, this  

 

  indicates, that either the battery charge level is low, the air 

fl

 ow is reduced due to a dirty 

fi

 lter, the hose assembly is blocked or    

  there is another possible problem.

4.10. BATTERY LEVEL INDICATOR
4.10.1. 

The battery level indicator light (

fi

 g 6 - 5) indicates the remaining charge in the battery.

4.11. 

  

TEST AIR FLOW

4.11.1. 

Disconnect hose assembly, SSP80PAPR.H05, (

fi

 g 4 - 5) from face hood, SSP80PAPR.H04, (

fi

 g 4 - 2).

4.11.2. 

Insert air 

fl

 ow meter, SSP80PAPR.12, (

fi

 g 7 - 1) into hose assembly connector, SSP80PAPR.H04, (

fi

 g 7 - 3).

4.11.3. 

Hold the 

fl

 ow meter vertically and start the blower (see section 4.9.1).

4.11.4. 

The 

fl

 ow meter ball should 

fl

 oat above the MIN mark (

fi

 g 7 - 2).

 

  

WARNING!

 If the 

fl

 ow meter indicates MIN or below turn the blower o

  (see section 4.9.5), then check the battery and 

fi

 lter  

 

 elements.

4.12. HEAD 

SHIELD 

ADJUSTMENT

4.12.1. 

Adjust the head shield circumference with the thumb wheel (

fi

 g 8 - 1) on the back band of the face shield. The thumb wheel is  

 

 

locked in position. Press the thumb wheel in to unlock, then twist clockwise to tighten and counterclockwise to loosen.    

 

 

At the desired circumference release the thumb wheel back into the locked position, .

4.12.2. 

Adjust the height by snapping the pin on the top band (

fi

 g 8 - 2) into the required hole location to lock securely in place.

4.12.3. 

To adjust the viewing angle, loosen the thumb wheels (

fi

 g 8 - 3) on both sides of the head shied and change the angle locker to the  

 

desired tilt position. There are 5 pre-set positions with the head shield supplied in the mid setting.

 

 

NOTE:

 The head shield should still be free enough to be raised up, but not to drift downwards.

4.12.4. 

To adjust the distance between the user’s face and the head shield’s clear lens, loosen the thumb wheels (

fi

 g 8 - 3) on both sides  

 

of the head shield until the headband can move back and forth freely. Position the headband into one of the 3 slots (

fi

 g 8 - 4), as    

 

desired (the head shield is supplied in the mid setting). This should be completed one side at a time and both sides must be 

 

 

located in the same location. Re-tighten the thumb wheels.

4.13. 

CHECKING THE FACE SHIELD WITH POWERED AIR PURIFYING RESPIRATOR BEFORE USE

 

Before using the respirator, check the following items:

 

   Air Filter Assembly: Ensure that the air 

fi

 lter is suitable for the application. Also be sure the 

fi

 lter is undamaged, and securely  

 

  connected to the blower assembly. See section 4.4.

 

   Hose assembly: Ensure the tube is undamaged and properly connected to the blower assembly and hood. See sections 4.6 & 4.7.

 

   Battery: Verify the battery is fully charged and securely connected to the blower assembly. See sections 4.1 & 4.2.

 

   Air Flow: Test air 

fl

 ow according to Section 4.11.

 

   Air Flow Alarm: Turn on blower assembly and check for audible, visual, and vibratory alarms. See section 4.8.

 

   Face Hood: Inspect the face hood, ensure it is attached correctly and replace if damaged.

4.14. PUTTING 

ON

 

THE FACE SHIELD WITH POWERED AIR PURIFYING RESPIRATOR

4.14.1. 

Place the blower assembly against the lower back with the hose assembly extending upwards (

fi

 g 9).

4.14.2. 

Fasten belt, SSP80PAPR.H08, around the waist and adjust to a comfortable 

fi

 t.

4.14.3. 

Place face shield assembly over and onto to head. Ensure it is a comfortable snug 

fi

 t.

SSP80PAPR  Issue 1 11/08/21

Original Language Version

© Jack Sealey Limited

   

fi

 g.6

BATTERY LEVEL INDICATOR

LEVEL INDICATOR LIGHT REMAINING POWER (%)

Green

90

Yellow

30 - 90

Red

10 - 30

Red - Flashing

0 - 10

   