4. OPERATION
Unpack the product and check contents. Should there be any damaged or missing parts contact your supplier immediately.
REFER TO ATTACHED PARTS LIST.
4.1.
CHARGING THE BATTERY
WARNING!
Allow the battery to cool before charging.
4.1.1.
Remove the battery pack, SSP80PAPR.BP, from the blower assembly (see section 4.3 below).
4.1.2.
Connect the charge cord connector to the charging socket on the battery pack, SSP80PAPR.BP, (fig 1 -1) and plug the mains charger,
SSP80PAPR.C, (fig 1 - 2) into a mains socket.
4.1.3.
When charging the indicator light on the mains charger will display red.
4.1.4.
When fully charged the indicator light on the mains charger will change to display green.
4.1.5.
When charging is complete, unplug the mains charger, SSP80PAPR.C, from the mains and the battery pack.
DO NOT
leave the battery pack on charge for long periods.
4.2.
BATTERY INSTALLATION
4.2.1.
Slide the battery pack, SSP80PAPR.BP, (
fi
g 2 - 1) into the blower body, SSP80PAPR.H09, (
fi
g 2 - 3) until it locks into place.
4.3.
BATTERY REMOVAL
4.3.1.
Hold the blower body (
fi
g 2 - 3)
fi
rmly and lift up the battery lock button (
fi
g 2 - 2), then slide and remove the battery pack (
fi
g 2 - 1).
4.4.
AIR FILTER INSTALLATION
4.4.1.
Remove
the
fi
lter cover, SSP80PAPR.F04 (
fi
g 3 - 4).
4.4.2.
Install
the
fi
lter, SSP80PAPR.F, (
fi
g 3 - 2) into the
fi
lter body, SSP80PAPR.F01, (
fi
g 3 - 1) and lock into position by screwing
clockwise until secure.
4.4.3.
Install the foam
fi
lter, SSP80PAPR.F03, (
fi
g 3 - 3) above the
fi
lter, SSP80PAPR.F, (
fi
g 3 - 2).
4.4.4.
Push
fi
t the
fi
lter cover, SSP80PAPR.F04, (
fi
g 3 - 4) until it “clicks” into position.
DO NOT
use the respirator without the
fi
lter cover, foam
fi
lter and
fi
lter installed.
DO NOT
wash
fi
lters, clean with compressed air, or reuse dirty air
fi
lters. Replace damaged or dirty air
fi
lter.
4.5.
AIR FILTER REMOVAL
4.5.1.
Removal of the
fi
lter is as section 4.4 but in reverse.
4.6.
ATTACHING THE HOSE ASSEMBLY TO BLOWER BODY
4.6.1.
Insert hose assembly connector, SSP80PAPR.H06, (
fi
g 4 - 6) into blower body connector outlet, SSP80PAPR.H07, (
fi
g 4 - 7) until
snug and then turn 1/8 turn clockwise to lock the hose assembly, SSP80PAPR.H05, (
fi
g 4 - 5) into place.
4.7.
ATTACHING THE HOSE ASSEMBLY TO FACE HOOD
4.7.1.
Thread the hose assembly connector, SSP80PAPR.H04, (
fi
g 4 - 4) into the face hood connection, SSP80PAPR.H03, (
fi
g 4 - 3) and
turn clockwise until the hose assembly, SSP80PAPR.H05, (
fi
g 4 - 5) locks into position.
4.8.
TESTING THE AIR FLOW ALARM
4.8.1.
Disconnect the hose assembly, SSP80PAPR.H05, (
fi
g 4 - 5) from face hood, SSP80PAPR.H02, (
fi
g 4 - 2).
4.8.2.
Start the blower, SSP80PAPR.H09, (
fi
g 5 - 1) and block the air
fl
ow by placing your hand over the open end of the hose assembly,
SSP80PAPR.H05,
(
fi
g 5 - 2).
4.8.3.
Continue to block the air
fl
ow (
fi
g 5) until the alarm sounds and the blower begins to vibrate.
4.8.4.
If the alarm does not sound and the blower fails to vibrate, check the battery and
fi
lter element.
4.9.
OPERATING THE CONTROLS
4.9.1. TO
START
4.9.2.
Press the ON/OFF button (
fi
g 6 - 1) for approx one second, until the blower starts (
fi
g 6 - 6).
4.9.3.
The low (
fi
g 6 - 2) and high (
fi
g 6 - 3) speed indicator lights will
fl
ash on, then o
ff
, the alarm sounds brie
fl
y and the blower will
vibrate
momentarily.
NOTE:
The blower will start in the low speed position.
4.9.4.
When the blower (
fi
g 6 - 6) is operating press the ON/OFF button (
fi
g 6 - 1) to alternate between low speed and high speed.
SSP80PAPR Issue 1 11/08/21
Original Language Version
© Jack Sealey Limited
fi
g.1
fi
g.3
fi
g.4
fi
g.2
fi
g.5