background image

 Original Language Version

screw tail-piece attachment (2) into drain tap(3) below sight 

glass. Attach suitable hose and open tap to drain.

once emptied, close drain tap and 

remove hose and tail-piece. 

fill with oil through plug hole (1) until oil is half way up the 

sight glass (4). Replace plug and refit shroud.

Once the oil and oil filter have been changed

leave the compressor to run for roughly 5

minutes then turn it off and check the oil 

level again. Add oil if necessary.

check the oil level once a week.

6.3.

 

REPLACING THE OIL FILTER CARTRIDGE.

6.3.1. 

Replace the oil filter cartridge after the first 500 hours of use 

 

then every 2500 hours and in any event each time the oil is 

 changed.

6.3.2. 

remove the upper plastic shroud to gain access 

 

to inside the compressor.

6.3.3. 

Remove filter cartridge (fig.9.1.) using a strap wrench and

 

replace with a new one.

6.3.4. 

Lubricate the sealing gasket before screwing the filter

 

cartridge tight.

6.3.5. 

Tighten the new filter cartridge manually. 

6.4 

REPLACING THE OIL SEPARATOR FILTER CARTRIDGE.

6.4.1. 

Replace the oil separator filter cartridge after the first 500

 

hours of use then every 2500 hours and in any event

 

each time the oil is changed.

6.4.2. 

remove the upper plastic shroud to gain access to inside

 

the compressor.

6.4.3. 

Remove filter cartridge (fig.10.2.), using a strap wrench and

 

replace with a new one.

6.4.4. 

Lubricate the sealing gasket before screwing the filter

 

cartridge tight.

6.4.5. 

Tighten the new filter cartridge manually.

 

6.5. 

REPLACING THE AIR FILTER CARTRIDGE.

6.5.1. 

remove the upper plastic shroud to gain access to inside  

 

the compressor.

6.5.2 

open the plastic cover.

6.5.3. 

Replace the air filter cartridge and replace the cover.

ssc11003   Issue: 1 - 03/05/13

© Jack sealey Limited

fig.7

fig.8

fig.9

fig.10

fig.11

Содержание SSC11003

Страница 1: ... electrical equipment and appliances to ensure they are safe before using You must inspect power supply leads plugs and all electrical connections for wear and damage You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices An RCCB Residual Current Circuit Breaker should be incorporated in the main distribution board You must also read and understan...

Страница 2: ... NOT operate the compressor without an inlet air filter 1 5 safety training good practice 7 DO NOT allow anyone to operate the compressor unless they have received full instructions and adequate training 3 KEEP THESE USE AND MAINTENANCE INSTRUCTIONS for future reference and make them available to the compressor operator The operator must be familiar with all the controls and compressor characteris...

Страница 3: ... any way Contact your local Sealey dealer for all repairs required Any unauthorised modification may impair the efficiency of the compressor and may also cause serious accidents for those who do not have the technical skill required to make such modifications 3 WE RESERVE THE RIGHT TO MAKE MODIFICATIONS WHERE NECESSARY WITHOUT NOTICE Original Language Version Compact high performance screw compres...

Страница 4: ...ld not be modified in any way Original Language Version 4 5 Connecting to the tank compressed air outlet Connect the compressor to the air delivery system using the quick coupler fig3 A Use hose of the same diameter or greater as the compressor outlet If a connection hose leaks or is faulty never try to repair it but replace with a sound one fig 3 fig 3 5 Operation WARNING Ensure that you have rea...

Страница 5: ...meters and recommendation stated in these instructions You are advised to keep a record of all maintenance jobs performed on the compressor 6 1 DRAINING CONDENSATE Drain the condensate from the air tank at least once a week by opening the draining valve under the tank fig 4 6 2 OIL CHANGE 6 2 1 Change the oil following the initial 500 hours of use and then every 2500 hours and in any event once a ...

Страница 6: ...lter cartridge fig 9 1 using a strap wrench and replace with a new one 6 3 4 Lubricate the sealing gasket before screwing the filter cartridge tight 6 3 5 Tighten the new filter cartridge manually 6 4 replacing the oil separator filter cartridge 6 4 1 Replace the oil separator filter cartridge after the first 500 hours of use then every 2500 hours and in any event each time the oil is changed 6 4 ...

Страница 7: ...sor stops thermal trip activated Excessive air oil mixture temperature Check oil level Check that air oil radiator is not blocked Compressor stops Motor overheating motor thermal relay activated Check that power supply is correct Check for loose cable connections and hot cables Check that motor cooling intake is not blocked or obstructed To resart the compressor allow to cool for a few minutes and...

Страница 8: ... will clog the pump intake filter and may cause internal damage to pump motor components Please note that any parts damaged by any type of contamination will not be covered by warranty Original Language Version Parts support is available for this product To obtain a parts listing and or diagram please log on to www sealey co uk email sales sealey co uk or phone 01284 757500 Environmental Protectio...

Страница 9: ......

Отзывы: