Issue No:
1
Issue Date:
040902
Item
Part No. Description
1C
EL3001C
Complete Motor
4
EL10004
Bearing
7
EL10007
Oil Seal
14
EL1014E
O-ring
16
EL40016
Impeller
19
EL20019
Pump Body
Item
Part No. Description
23
EL10023
Sponge
24
EL10024
Capacitor
39
EL10039
Switch
45
EL10045
Upper Body
46
EL10046
Connector
61
EL50061
Suction Base
PARTS LIST FOR:
WATER PUMP
MODEL:
SDW50A
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
5. DECLARATION OF CONFORMITY
SUBMERSIBLE WATER PUMP
Model: SDW50A
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
Declaration of Conformity
We, the sole importer into the UK, declare that the product listed below is in conformity with the following standards and directives.
4th September 2002
Signed by Mark Sweetman
The construction file for this product is held by the Manufacturer and may be inspected, by a national authority, upon
request to Jack Sealey Ltd.
For Jack Sealey Ltd.
Sole importer into the UK
of Sealey Power Products.
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT:
No liability is accepted for incorrect use of product.
WARRANTY:
Guarantee is 12 months from purchase date, proof of which will be required
for any claim.
INFORMATION:
For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
a. The thermal circuit
breaker cuts in as the
motor has overheated.
b. Motor operates but
there is no flow.
c. Reduced flow
for level of water.
d. The pump will not start
or suddenly stops
during operation.
1. No electrical power.
2. Float switch fault.
3. Circuit breaker has triggered.
4. Impeller is jammed.
1. Check cable, plug and fuse.
2. Contact authorised service agent.
3. See (a) above.
4. Clean the pump.
1. Discharge pipe bent, or pinched.
2. Discharge pipe too narrow.
3. Pump partially blocked.
1. Straighten pipe.
2. Use larger diameter pipe.
3. Clean pump.
1. The water level is too low.
2. Intake blocked, impeller jammed.
3. Temperature of inlet water exceeds 35
O
C.
1. Water level below min suction depth.
2. Air bubbles in pump accumulated during submersion, or because float is incorrectly
positioned so pump does not stop at minimum level and sucks in air.
3. Clogged intake filter or discharge pipe.
1. Stop the pump.
2. Release air by inclining the pump and re-immersing it in water.
3. Remove blockage and clean the unit.
1. Sink the pump deeper, or allow to cool before continuing use.
2. Check and clean.
3. Reduce water temperature. Allow the pump to cool for approx 25minutes before restarting.
TROUBLESHOOTING
Sole UK Distributor,
Sealey Group
, Bury St. Edmunds, Suffolk.
01284 757500
www.sealey.co.uk
01284 703534
Web