6. TROUBLESHOOTING
6.1.
Upon fault of the dehumidifier, please cut off the power supply immediately, unplug the plug and check the following items:
6.2.
If the said methods still fail to eliminate the above problems, please directly contact the manufacturer or agents.
DO NOT
disassemble
the dehumidifier, contact Sealey for repairs.
6.3.
It’s normal to hear the sound of the circulation of refrigerant when the dehumidifier runs.
6.4.
It’s normal for the air vent to blow warm air.
6.5.
INFORMATION FOR THE USER:
6.5.1.
As a precision part, the humidity sensor may be damaged when used in environment filled with strong corrosive gas and heavy dust.
6.5.2.
As the dehumidifier is non-resistant against explosion, it’s forbidden to be used in environment of special requirements such as that
filled with combustible/explosive gas, dust, chemicals or biological products.
6.5.3.
Damage caused to the dehumidifier by use in said environment will void the warranty.
6.5.4.
As water may be discharged from the machine after a certain amount of use, attention shall be paid to managing this water.
6.5.5.
To minimize faults and maximize the lifetime, press the buttons gently.
6.5.6.
The deviation between the humidity shown on the sensor and the actual humidity is normal, due to impact by the location, environment
and temperature.
6.5.7.
Since the cooled air is dried by the condenser before being discharged during operation of the dehumidifier, it’s normal for the air
discharged to be hotter than the environment. Withdraw and clean air filter with dry and clean cloth regularly.
6.5.8.
Since the dehumidifying effect is associated with the temperature and humidity of the environment, the higher the temperature
and humidity of the environment, normally the greater the dehumidifying effect; while the lower the temperature and humidity of the
environment, typically the lower the dehumidifying effect.
A
Power Indicator Light
B
T
imer Indicator Light
C
O
n/Off Set
D
Set Timer
E
I
ncrease Set Time/Humidity
F
R
educe Set Time/Humidity
Original Language Version
© Jack Sealey Limited
Faults
Cause Analysis
S
olutions
Fails to turn on
S
hown as no power
No power to the wall socket.
Check the power supply.
Check the plug plugged in
properly.
Plug the power supply in the socket.
Check the fuse is not blown.
Replace the fuse.
P
ower Transformer is broken.
Replace the transformer.
S
hown as power on
Environmental humidity lower
than the set value.
S
et again according to the demand.
If the water tank is installed
correctly.
Place the water tank in right position.
If the entire machine is defrosting. Wait for the completion of defrosting cycle.
Unfavourable
dehumidifying effect
If the air inlet/outlet is obstructed.
Remove the obstacle.
If the door and window are open.
Close the door and window.
If the indoor temperature is too low.
D
on’t run the dehumidifier.
Heavy noise
I
f the ground is firm and flat.
R
esettle the dehumidifier.
D
ehumidifier is stood precariously.
R
esettle the dehumidifier.
Water leakage
D
ehumidifier stood on an incline.
M
ove dehumidifier to a level surface.
Drain pipe/outlet obstructed.
Dismantle the front plate to eliminate blockages.
E1
Coil sensor fault
T
urn to timing for defrosting, to cancel system fault
function.
E2/E3
Fault of humidity & temperature sensor.
Replace the humidity & temperature sensor.
EE
Refrigerant leakage.
S
tart the machine after. Ask for help from
professionals if the “EE” signal remains.
S
DH70.V2 Issue 1 07/06/2021