Sealey SCT125 Скачать руководство пользователя страница 5

WARNING! – Risk of Hand Arm Vibration Injury.

This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.

This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC.

This tool is to be operated in accordance with these instructions.

Measured vibration emission value (a):   . . . . . . . . . .

4.96 m/s²

Uncertainty value (k):. . . . . . . . . . . . . . . . . . . . . . . . . .

2.48 m/s²

Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a

specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.

A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool. 

NB: 

Stated Vibration Emission values are type-test values and are intended to be typical. 

Whilst in use, the actual value will vary considerably from and depend on many factors.  

Such factors include; the operator, the task and the inserted tool or consumable. 

NB:

 ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.

The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration 

Syndrome.

Health surveillance.

We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified 

accordingly.

Personal protective equipment.

We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the 

uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and 

maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and 

Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSC website 

www.hse.gov.uk - Hand-Arm Vibration at Work.

Содержание SCT125

Страница 1: ...the appliance by the power cable 1 1 8 DO NOT pull the plug from the socket by the cable 1 1 9 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician When a BS 1363 A UK 3 pin plug is damaged cut the cable just above the plug and dispose of the plug safely Fit a new plug according to the following instructions UK only ...

Страница 2: ...f saw misuse and or incorrect operating procedures or conditions and can be avoided by taking proper precautions as given below Maintain a firm grip on the saw and position your arms to resist kickback forces Position your body to either side of the blade but not in line with the blade Kickback could cause the saw to jump backwards but kickback forces can be controlled by the operator if proper pr...

Страница 3: ...8m s Noise Power 101dB A Noise Pressure 90dB A Affix the auxilliary handle fig1 7 Select the required rear handle position by pressing the handle locking button fig 1 6 and turning the handle appropriately 4 1 SAWING WARNING Ensure that the power flex is always laid well clear of the saw blades 4 1 1 Secure the work to a stable support before attempting to cut 4 1 2 Ensure that the workpiece is su...

Страница 4: ... 3 CARBON BRUSH REPLACEMENT 5 3 1 If excessive sparking is noticed from within the machine check the condition of the carbon brushes These will wear down with use and are a consumable item WARNING Ensure that the saw is disconnected from the power supply 5 3 2 To check the brushes Unscrew the brush holder caps fig 6 on either side of the machine 5 3 3 Removing the caps will reveal the carbon brush...

Страница 5: ...lude the operator the task and the inserted tool or consumable NB ensure that the length of leader hoses is sufficient to allow unrestricted use as this also helps to reduce vibration The state of maintenance of the tool itself is also an important factor a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome Health surveillance We recommend a programme of health surve...

Отзывы: