background image

 

8

   do not

 operate the cabinet if any parts are damaged or missing as this may cause failure and/or personal injury.

 

8

   do not

 operate the cabinet with the a side door open.

 

8

   do not

 use the gun without appropriate nozzles fitted.

 

8

   do not

 stand on the cabinet.

 

8

   do not

 get the cabinet wet or use in damp or wet locations or areas where there is condensation.

 

8

   do not

 operate cabinet when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

   do not

 leave the cabinet operating unattended.

 

   imPoRtant 

The viewing screen is 5mm tempered glass. If the glass should break ensure that it is replaced with tempered or safety  

  glass only.

 

9

   When not in use disconnect from the electrical mains and the air power supply.

 

NOTE! We strongly recommend that a suitable dust extraction system is used with this unit.

2.  intRoduction

 

Heavy-duty steel cabinets with toughened glass viewing screen and integral low voltage illumination. double side doors on model no.  

 

SB974 provide easy access for bulkier items. Includes dust extraction port. Supplied with heavy gauntlets, sand blasting gun and four  

 

ceramic nozzles. Suitable for glass beads, silicon carbide, aluminium oxide and silica sand only.

3.  sPeciFication

Capacity ......................................................................0.33m

3

operating pressure .............................................. 60 - 120psi

m

ax air flow

 .................................................................. 15cfm

Air inlet ......................................................................1/4”BSP

extraction port ........................................................... Ø64mm

Width/depth/Height ...............................960 x 720 x 1500mm

Viewing area .....................................................580 x 270mm

doors ...................................................................................2

4.  assemblY

4.1.    

assemblY

 (This cabinet should be assembled by two people).

4.1.1.   

Unpack the product and check contents. Should there be any damaged or missing 

 

parts contact your supplier immediately. 

4.1.2.   

Connect the leg ends to legs (fig 1.1 & 2.) by passing screws from the outside and 

 

tightening with nuts and washers on the inside of the leg.

4.1.3.   

Attach the four legs to cabinet frame (3) with screws, washers and nuts.

4.1.4.   

Fasten shelf (4) to holes in the middle of the four legs.

4.1.5.   

Carefully peel backing paper from the foam sealing strip and lay the sticky surface on 

 

the upper edge of frame (3). Trim as required, and make screw holes in foam (in some 

 

cases the foam may already be attached).

4.1.6.   

Site funnel (5) so that it passes through the hole in shelf (4) and sits on frame (3) with 

 

the funnel outlet locking lever (A) facing to the front of the cabinet. 

4.1.7.   

Sit the wire mesh shelf (6) in the top of funnel (5).  

4.1.8.   

Stick further sealing strip all around the edge of the funnel.

4.1.9.   

Sit cabinet (7) on top of funnel, ensuring that all the sealing strips are intact and fix 

 

the cabinet and funnel to frame (3) with screws, washers and nuts. 

4.1.10.  If not already attached, connect gun (8) to hose (9) at the nozzle outlet end of gun (B).

4.1.11.  Push other end of hose (9) onto the shot media input pipe inside the funnel (10).

4.2.    

installation

4.2.1.   

You will require an air pressure of between 40-80psi, and an air volume of 15cfm for operating the unit. 

 

   WaRning! 

Ensure air supply does not exceed 100psi. Too high an air pressure and/or unclean air will shorten the cabinet 

 

life due

 

to excessive wear, and may be dangerous causing possible damage and personal injury.

4.2.2.   

The air supply must be clean and dry. drain the air supply tank daily. Water in the air line will damage the item being blasted and will 

 

invalidate the cleaning tank warranty.

4.2.3.   

Clean the compressor air inlet filter screen weekly. For recommended hook-up, see diagram below (fig.2).

4.2.4.   

line pressure should be increased to compensate for 

 

unusually long air hoses (over 8 metres). The 

minimum

 

 

hose diameter should be 10mm I.d. and fittings must

 

have the same inside dimensions.

4.2.5.   

Keep hose away from heat, oil and sharp edges. Check 

 

hoses for wear. make certain all connections are secure.

4.2.6.   

Use an appropriate coupling suitable for your air system to 

 

connect to the 1/4” inlet air coupling on the gun. Pass the 

 

air line through the cabinet inlet hole (d).

4.2.7.   

ensure the air gun (8) trigger is ‘off’ before connecting to the air supply.

4.2.8.   

Check all fittings to ensure there are no leaks and check that the media supply hose is tightly attached to the underside of the gun.

4.2.9.   

Place abrasive into the centre of cabinet funnel, by pouring through the side door, until it is 

half

 

full

.

 

8

   do not

 exceed the stated amount. excessive amounts of abrasive will impair visibility, create poor blasting performance and could 

 

block the air exhaust at the rear of the cabinet.

4.2.10.  Plug the transformer connector into the electrical inlet (e) at the rear of the blast cabinet. Plug the transformer into the mains socket.

4.3.    

dust  extRaction 

If not using an extraction system, remove the cover from air flow outlet (Z) at rear right hand side of the cabinet to  

 

allow air flow.

Original Language Version

© Jack Sealey limited

fig.1

fig.2

SB974.V5    Issue 3 (3,4)     21/08/19

Содержание SB974.V5

Страница 1: ... 8 DO NOT try to open or dis assemble the transformer plug 8 8 DO NOT use the transformer plug to power any other electrical item 8 8 DO NOT get the transformer wet or use in wet damp conditions for indoor use only WARNING NEVER substitute a standard 13 Amp 3 pin plug or any other type of plug for the transformer plug CABLE EXTENSION REELS When a cable extension reel is used it should be fully unw...

Страница 2: ...binet 4 1 7 Sit the wire mesh shelf 6 in the top of funnel 5 4 1 8 Stick further sealing strip all around the edge of the funnel 4 1 9 Sit cabinet 7 on top of funnel ensuring that all the sealing strips are intact and fix the cabinet and funnel to frame 3 with screws washers and nuts 4 1 10 If not already attached connect gun 8 to hose 9 at the nozzle outlet end of gun B 4 1 11 Push other end of h...

Страница 3: ... 7 Before opening the cabinet to check progress or to access content release the trigger and lay the gun on the mesh shelf Remove your gun hand first and then your other hand Only then is it safe to open the side door 5 8 When work is complete disconnect gun from the air line unplug from the mains electrical supply and switch off dust extraction 6 maintenance WARNING Ensure the cabinet is disconne...

Страница 4: ...se of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually improve products and as such we reserve the right to alter da...