5.3.4.
timer setting:
a) upon start, press the timer button to enter timed shutdown. upon shutdown, press this button to enter timed start. the timer
indicator will illuminate.
b) Press the Timer button to enter the timing function (timed start/timed shutdown). Adjust the up or down button to set the timing time.
the time will cycle in the order of
1-2-3-……....24 0 - 1 hours or
24-23-22-……1 0 - 24 hours.
c) After timed start is set, once the timed start time is reached, the unit will start.
in the meantime, the timer indicator will extinguish and the ambient temperature is displayed.
d) After timed shutdown is set, when the shutdown time is reached the unit will shut down.
in the meantime, the timer indicator will extinguish and the ambient temperature is displayed.
e) Only the final setting of the timing function is activated. This setting is for one operation.
f) ON/OFF selection on the Control Panel or Remote Control will clear all timing settings.
g) once the timing is determined, if the timer button is pressed once, it is possible to query the
remaining timed start/shutdown time. If the timer button is pressed twice continuously within 5
seconds, the timing will be cancelled.
5.4.
remote control operating instructions
Power button: press this button to turn on/off the unit;
timer button: upon shutdown, press this button to set timed start; upon start, press this button to
set timed shutdown.
High button: press this button to allow the unit to operate in the high fan speed state (except in
the dry and sleep modes);
low button: press this button to allow this unit to operate in the low fan speed state;
up button: press this button to increase the temperature and timing value;
down button: press this button to decrease the temperature and timing value;
°c — f button: press this button to switch between the celsius and fahrenheit;
cool button: press this button to set this unit to operate in the cooling mode.
fan button: press this button to set this unit to operate in the air supply mode.
dry button: press this button to set this unit to operate in the dry mode.
sleep mode: press this button to set this unit to operate in the sleep mode.
5.5.
antifreeze protection function
upon cooling, when the compressor operates continuously for more than 10 minutes, if the pipe temperature tp is less than or equal
to 2°c continuously for 20 seconds, the compressor and water spraying motor turn off, other loads operate and led displays e4.
the unit initiates the anti-frost protection function and the buttons are inactive (except the off button). once the pipe temperature
rises to exceed or equal 8°c, the protection is relieved, the original status is restored and the unit meets the requirements for 3-minute
delay protection of the compressor.
5.6.
full water protection function
When the water in the water tray exceeds the alarm level, the unit will alarm automatically and the full water indicator illuminates.
drain the condensate in the unit; otherwise, the unit will shut down automatically after the buzzer gives off 5 beeps.
(For more information about the drain method, refer to Section 6. If the unit is not shut down manually, the unit will be restored to the
previous operating status automatically once the water is fully drained. or the power may be turned on again to start the unit.
5.7.
delay protection function of the compressor
this unit offers restart protection for the compressor. except that the compressor may start immediately when the unit is energized for
the first time, there is 3 minute delay start protection after the compressor is shut down.
6. Water drainaGe
6.1.
manual drain (fig 6)
the unit will shut down when the water level is full.
turn off the power and unplug the power cable.
note:
move the unit carefully to avoid spillage of water in the water tray at the bottom of the unit.
Place a vessel beneath the water outlet, at the back of the unit, to drain water.
Unscrew the drain cap and remove the water plug to allow water to flow into the vessel.
note:
Protect the drain cap and water plug from becoming detached. tilt the unit slightly backward when draining.
fig.6