5.  operation

5.1.    

function setting

 

this air conditioner has 3 functions: cooling, dehumidifying and fan. 

5.2.   

 

control keys

 

power key: 

press to turn on/off.

 

mode key: 

sets cooling, dehumidifying and fan modes.

 

fan speed: 

press to select high/low fan speed (not available in dehumidifying mode.)

 

timer key: 

when setting the time the regular time indicator will light.

 

up/down key: 

press these buttons to set the desired room temperature and time.

 

switch between °c and °f by pressing these two keys simultaneously or by using the remote control.

5.3.   

 operation

5.3.1.   

cooling mode:

 

Ta≥Ts +1°C (1°F), the cooling will start.

 

Ta≤Ts -1°C (1°F), the compressor stops and only the fan motor remains working at the set fan speed.

 

ta: room surrounding temperature

 

ts: setting temperature

 

in this mode, press timer and down button to set sleep function, in sleep function, after operating two hours, the set temperature  

 

increases 1°c (1°f) automatically.

 

After operating for another 2 hours, the set temperature will increase 1°c (1°f) again. then the set temperature will not change and  

 

the fan will switch to low level.

5.3.2.   

dehumidifying mode:

 

 If the ambient temperature ≥17°C (62°F), the compressor will start. Then, the unit is controlled in the following manner: 

 

When the ambient temperature ≤15°C (59°F), the compressor shuts down. 

 

When the ambient temperature rises to be ≥17°C (62°F), the compressor starts again. The start/stop of the compressor meets the  

 

requirement for 3-minute protection time.

5.3.3.   

fan mode:

 

Fan runs on both high speed or low speed. Temperature setting displays environment temperature between 0 / 35°C (50 / 95°F).

fig.5

fig.4

s

AC9001 | Issue 3 (L) 29/11/16

Original Language Version

© Jack sealey limited

Содержание Sac9001

Страница 1: ...appliance by the power cable 8 8 DO NOT pull the plug from the socket by the cable Remove the plug from the socket by maintaining a firm grip on the plug 8 8 DO NOT use worn or damaged cables plugs or connectors Ensure that any faulty item is repaired or replaced immediately by a qualified electrician 1 3 This product is fitted with a BS1363 A 13 Amp 3 pin plug If the cable or plug is damaged remo...

Страница 2: ...e by children without supervision 2 introduction Thermostatically controlled unit with extendible exhaust hose and window kit ideal for home or office environments Features two speed fan and electronic remote control Air conditioning temperature range 17 30 C Also features a dehumidifying function capable of removing up to 24ltr day Refrigerant is R410A Mounted on castors for manoeuvrability Cable...

Страница 3: ... shown in Fig 1 vertical or Fig 2 horizontal 4 5 Position the mobile air conditioner with the exhaust hose assembly attached near to a window Keep the mobile air conditioner at least 50cm away from the walls or other objects As shown in Fig 3 4 6 Snap the flat end of the exhaust hose connector into the elliptical hole of the window sealing board assembly as shown in Fig 4 and Fig 5 4 7 To ensure a...

Страница 4: ...etting Temperature In this mode press Timer and Down button to set sleep function In sleep function after operating two hours the set temperature increases 1 C 1 F automatically After operating for another 2 hours the set temperature will increase 1 C 1 F again Then the set temperature will not change and the fan will switch to low level 5 3 2 Dehumidifying mode If the ambient temperature 17 C 62 ...

Страница 5: ...e Dry button press this button to set this unit to operate in the dry mode Sleep mode press this button to set this unit to operate in the sleep mode 5 5 Antifreeze protection function Upon cooling when the compressor operates continuously for more than 10 minutes if the pipe temperature Tp is less than or equal to 2 C continuously for 20 seconds the compressor and water spraying motor turn off ot...

Страница 6: ...er mesh are clogged with dust the function of the air conditioner may decrease 7 2 3 Remove the evaporator filter frame and the condenser filter frame gently in the direction shown by the arrow as shown in Fig 9 7 2 4 Remove the evaporator filter mesh and condenser filter mesh gently in the direction shown by the arrow as shown in Fig 10 7 2 5 Remove the filter frame first and then take out the fi...

Страница 7: ... suitable vessel Note DO NOT tilt the unit any further than 30 from vertical 9 2 Start the unit adjust mode to the low fan speed setting keep the unit in this state for half a day in order to dry the interior of the unit to prevent mould 9 3 Turn off the unit unplug the power plug wrap the power cord around the wire winding post insert the plug into the storage point on the rear of the unit instal...

Страница 8: ...completely unserviceable and requires disposal drain off any fluids if applicable into approved containers and dispose of the product and the fluids according to local regulations WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of ...

Отзывы: