background image

instructions for

air conditioner/dehumidifier 9000btu/hr

model no: 

Sac9001

thank you for purchasing a Sealey product. manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SafetY

1.1.    

electrical Safety

 

‰

  

WarninG!

 it is the user’s responsibility to check the following:

1.1.1.   

check all electrical equipment and appliances to ensure that they are safe before using. inspect power supply leads, plugs and all

 

electrical connections for wear and damage. ensure the risk of electric shock is minimised by the installation of appropriate safety

 

devices. An rccB (residual current circuit Breaker) should be incorporated in the main distribution board. We recommend that an

 

rcd (residual current device) is used with all electrical products. it is particularly important to use an rcd with portable products

 

that are plugged into a supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain an RCD by

 

contacting your local sealey dealer. 

 

electrical safety information, it is important that the following information is read and understood.

1.2. 

  

The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified

 

electrician, using a Portable Appliance tester (PAt), at least once a year.

1.2.1.   

the Health & safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.2.2.   

ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and use a

 

Portable Appliance tester.

1.2.3.   

ensure that cables are always protected against short circuit and overload.

 

regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

 

Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct

 

fuse - see fuse rating in these instructions.

 

8

  

do not

 pull or carry the appliance by the power cable.

 

8

  

do not

 pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a firm grip on the plug.

 

8

  

do not

 use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or replaced immediately by a   

  qualified electrician.

1.3. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug.

 

if the cable or plug is damaged, remove from use and ensure that repairs are carried out by a 

 

qualified electrician.

 

Replace a damaged plug with a BS1363/A 13A 3 pin plug. If in doubt contact a qualified electrician.

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires and ensure that wires have been correctly connected. 

 

ensure that the cable outer sheath extends beyond the cable restraint and that the restraint is tight. 

 

double insulated products are marked with the class ii symbol. 

 

class ii products are wired with live (brown) and neutral (blue) only. to rewire, 

 

connect the wires as indicated in diagram.

 

do not

 connect either wire to the earth terminal.

 

Products which require more than 13 amps are supplied without a plug. Contact a qualified electrician 

 

to ensure that a suitably rated supply is available. ensure that an industrial round pin plug and socket are 

 

fitted by a qualified electrician.

 

if an extension cable reel is used, ensure that it is fully unwound before connection. use a reel that includes an rcd, an appliance  

 

will be protected by the rcd. the cable core section is important and should be at least 1.5mm². ensure that the cable of the reel is  

 

appropriate for this product. We recommend the use of 2.5mm² core section cable.

1.4.    

General Safety

 

9

   check that the unit is in sound condition and good working order. take immediate action to repair or replace damaged parts.

 

9

   use recommended parts only. unauthorised parts may be dangerous and will invalidate the warranty.

 

8

  

do not

 stand or place any object closer than 500mm from the unit.

 

8

  

do not

 obstruct the air intakes or outlets of the unit, and do not cover with washed clothes.

 

8

  

do not

 place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

8

  

do not

 operate the unit when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

do not

 switch the unit off by disconnecting it from the mains. ALWAYS switch to the “OFF” position first.

 

8

  

do not

 remove the float lever from the water collection tank.

s

AC9001 | Issue 3 (L) 29/11/16

Original Language Version

© Jack sealey limited

refer to

instruction

manual

recommended fuse rating

13amp

Содержание Sac9001

Страница 1: ...appliance by the power cable 8 8 DO NOT pull the plug from the socket by the cable Remove the plug from the socket by maintaining a firm grip on the plug 8 8 DO NOT use worn or damaged cables plugs or connectors Ensure that any faulty item is repaired or replaced immediately by a qualified electrician 1 3 This product is fitted with a BS1363 A 13 Amp 3 pin plug If the cable or plug is damaged remo...

Страница 2: ...e by children without supervision 2 introduction Thermostatically controlled unit with extendible exhaust hose and window kit ideal for home or office environments Features two speed fan and electronic remote control Air conditioning temperature range 17 30 C Also features a dehumidifying function capable of removing up to 24ltr day Refrigerant is R410A Mounted on castors for manoeuvrability Cable...

Страница 3: ... shown in Fig 1 vertical or Fig 2 horizontal 4 5 Position the mobile air conditioner with the exhaust hose assembly attached near to a window Keep the mobile air conditioner at least 50cm away from the walls or other objects As shown in Fig 3 4 6 Snap the flat end of the exhaust hose connector into the elliptical hole of the window sealing board assembly as shown in Fig 4 and Fig 5 4 7 To ensure a...

Страница 4: ...etting Temperature In this mode press Timer and Down button to set sleep function In sleep function after operating two hours the set temperature increases 1 C 1 F automatically After operating for another 2 hours the set temperature will increase 1 C 1 F again Then the set temperature will not change and the fan will switch to low level 5 3 2 Dehumidifying mode If the ambient temperature 17 C 62 ...

Страница 5: ...e Dry button press this button to set this unit to operate in the dry mode Sleep mode press this button to set this unit to operate in the sleep mode 5 5 Antifreeze protection function Upon cooling when the compressor operates continuously for more than 10 minutes if the pipe temperature Tp is less than or equal to 2 C continuously for 20 seconds the compressor and water spraying motor turn off ot...

Страница 6: ...er mesh are clogged with dust the function of the air conditioner may decrease 7 2 3 Remove the evaporator filter frame and the condenser filter frame gently in the direction shown by the arrow as shown in Fig 9 7 2 4 Remove the evaporator filter mesh and condenser filter mesh gently in the direction shown by the arrow as shown in Fig 10 7 2 5 Remove the filter frame first and then take out the fi...

Страница 7: ... suitable vessel Note DO NOT tilt the unit any further than 30 from vertical 9 2 Start the unit adjust mode to the low fan speed setting keep the unit in this state for half a day in order to dry the interior of the unit to prevent mould 9 3 Turn off the unit unplug the power plug wrap the power cord around the wire winding post insert the plug into the storage point on the rear of the unit instal...

Страница 8: ...completely unserviceable and requires disposal drain off any fluids if applicable into approved containers and dispose of the product and the fluids according to local regulations WEEE Regulations Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of ...

Отзывы: