SAC9000 - 1 - 241106

6. MAINTENANCE

6.1

General Maintenance.

Turn the unit OFF and disconnect it from the mains power supply before cleaning or 

performing any maintenance.

6.1.2 Inspect the unit on a regular basis and replace or repair any damaged parts. 

Use recommended parts and an

authorised service agent

.

Unauthorised parts may be dangerous and will invalidate the warranty.

6.1.3 Do not use any solvents or abrasive material to clean the plastic exterior of the unit. Use only a damp soft cloth 

for cleaning and dry the unit afterwards with a clean, dry, soft cloth.

6.2

Air Filter.

If the air filter becomes blocked with dust this will effect the efficiency of the unit. The air filter should 

be checked after every two or three uses. Remove the air filter (see above) from behind the back air 
inlet vent and clean it as follows. Remove any excess of dust using a small soft brush such as a clean paint 
brush. Prepare a container of warm water (40°C) containing a neutral detergent and immerse the filter in it. 
Gently agitate the filter in the water then rinse it in clean water. Shake off any excess water and leave it in a safe
place to air dry. Reinsert the filter into the unit. Do not run the unit without the filter.

6.3

Drainage.

When the unit is cooling/dehumidifying, condensed water will drain into the internal water tank which 

has a capacity of two litres. When the tank is full a buzzer will sound 20 times and an error code ‘E4’ will appear 
at the bottom of the main display. The cooling system will switch off automatically and the fan will cut out after 3 
minutes. The system cannot be restarted until the tank has been drained.

6.3.1 Turn off the unit and unplug it from the mains supply.
6.3.2 Place the drainage tray under the drainage outlet.
6.3.3 Unscrew the drainage cap and prepare to remove the bung.

NOTE: The inner tank may contain more water than the capacity of the drain tray. Be prepared to 
replace the bung before the tray is full.

6.3.4 Remove the rubber bung and allow the water to drain. Replace bung before tray is full.
6.3.5 Repeat the above steps until all the water has been drained.
6.3.6 Replace the rubber bung.
6.3.7 Screw the drainage cap back onto the drainage outlet and tighten it to fully push the bung home.

6.4

Continuous Drainage.

To provide continuous drainage for the unit remove the drainage cap and rubber bung

and push the black plastic hose supplied onto the drainage outlet. For effective drainage keep the open end of 
the hose at a lower level than the drainage outlet. The hose can be extended if required with 18mm plastic pipe.

6.5

If the unit is to be unused for sometime be sure to drain all condensed water from the tank.

Содержание SAC9000

Страница 1: ...necting it to the power supply See 1 1 1 and 1 1 2 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the appliance matches the power supply to be used and ...

Страница 2: ...ch it is designed DO NOT allow the unit to get wet as this may cause an electric shock and will damage the unit DO NOT let the power lead touch a hot surface lie in a hot airflow or run under a carpet DO NOT insert or allow objects to enter any openings of unit as this may cause an electric shock fire or damage to unit DO NOT use in bathroom shower room or in any environment of excessive condensat...

Страница 3: ...ush the inner adaptor into the exhaust air outlet on the back of the unit See fig 1 7 The exhaust can be extended from 0 55m to 1 55m The unit is at its most efficient when the air duct is shorter Use only the duct supplied Do not further extend the length of the duct with other ducting as this will reduce the efficiency of the unit 4 2 Exhaust duct placement See fig 3 Site the unit close to a doo...

Страница 4: ... on again it will run with the previous settings 5 2 Mode Descriptions AUTO The internal microprocessor will switch the compressor and fan on or off to automatically maintain the temperature set on the control panel COOL When the room temperature is higher than the temperature set on the control panel the compressor will start to provide a cooling action When the room temperature is lower than the...

Страница 5: ... display 5 6 Airflow Direction Adjustment The direction of the air output can be changed manually by tilting the louvre assembly at the front of the unit To move the airflow up and down tilt the whole louvre assembly as show in B below To move the air flow from side to side use the tilt control to be found in the centre of the louvre as shown in A below 5 7 Remote Control Operation The remote cont...

Страница 6: ...the unit is cooling dehumidifying condensed water will drain into the internal water tank which has a capacity of two litres When the tank is full a buzzer will sound 20 times and an error code E4 will appear at the bottom of the main display The cooling system will switch off automatically and the fan will cut out after 3 minutes The system cannot be restarted until the tank has been drained 6 3 ...

Страница 7: ...cool air coming out in dehumidifying mode No hot air coming out in heating mode Error code E2 appears at bottom of display panel on unit Error code E3 appears at bottom of display panel on unit Error code E4 appears at bottom of display panel on unit POSSIBLE CAUSES Power supply fault 1 Not plugged in 2 Damaged plug or socket 3 Internal fuse blown 1 Timer is set or room temperature is lower than t...

Отзывы: