4. INSTALLATION

SAC9000 - 1 - 241106

CONTENTS  / MAIN FEATURES (See fig.1)

1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control Panel
2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Outlet
3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Handle
4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Castor
5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Filter
6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Inlet
7 . . . . . . . . . . . . . . . . . . . . . . . . . . Exhaust Air Outlet
8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable Stowage

9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water Stopper
10 . . . . . . . . . . . . . . . . . . Inner Exhaust Duct Adaptor
11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Exhaust Duct
12 . . . . . . . . . . . . . . . . . . Outer Exhaust Duct Adaptor
13 . . . . . . . . . . . . . . . . . . . . . . . Water Collection Tray 
14 . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote Control
15. . . . . . . . . . . . . . . . . . . . . Outer Exhaust Duct Cap

Fig.2

Fig.3

4.1 Assembling the exhaust duct.

See fig.2. First extend each end of the duct (11) and attach the inner adaptor 

(10) and the outer adaptor (12) using a clockwise threading action. Push the inner adaptor into the exhaust air 
outlet on the back of the unit. See fig.1-7. The exhaust can be extended from 0.55m to 1.55m. The unit is at its 
most efficient when the air duct is shorter. Use only the duct supplied. Do not further extend the length of the duct
with other ducting as this will reduce the efficiency of the unit.

4.2 Exhaust duct placement.

See fig.3. Site the unit close to a door or window that can be left ajar, as indicated 

below. Place the end of the duct in the opening and if necessary tie it in place. Do not allow the duct to be 
overstretched. Do not allow the duct to be kinked or distorted or blocked as this will overheat the unit. If the unit 
becomes overheated it will automatically shut down.

Содержание SAC9000

Страница 1: ...necting it to the power supply See 1 1 1 and 1 1 2 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the appliance matches the power supply to be used and ...

Страница 2: ...ch it is designed DO NOT allow the unit to get wet as this may cause an electric shock and will damage the unit DO NOT let the power lead touch a hot surface lie in a hot airflow or run under a carpet DO NOT insert or allow objects to enter any openings of unit as this may cause an electric shock fire or damage to unit DO NOT use in bathroom shower room or in any environment of excessive condensat...

Страница 3: ...ush the inner adaptor into the exhaust air outlet on the back of the unit See fig 1 7 The exhaust can be extended from 0 55m to 1 55m The unit is at its most efficient when the air duct is shorter Use only the duct supplied Do not further extend the length of the duct with other ducting as this will reduce the efficiency of the unit 4 2 Exhaust duct placement See fig 3 Site the unit close to a doo...

Страница 4: ... on again it will run with the previous settings 5 2 Mode Descriptions AUTO The internal microprocessor will switch the compressor and fan on or off to automatically maintain the temperature set on the control panel COOL When the room temperature is higher than the temperature set on the control panel the compressor will start to provide a cooling action When the room temperature is lower than the...

Страница 5: ... display 5 6 Airflow Direction Adjustment The direction of the air output can be changed manually by tilting the louvre assembly at the front of the unit To move the airflow up and down tilt the whole louvre assembly as show in B below To move the air flow from side to side use the tilt control to be found in the centre of the louvre as shown in A below 5 7 Remote Control Operation The remote cont...

Страница 6: ...the unit is cooling dehumidifying condensed water will drain into the internal water tank which has a capacity of two litres When the tank is full a buzzer will sound 20 times and an error code E4 will appear at the bottom of the main display The cooling system will switch off automatically and the fan will cut out after 3 minutes The system cannot be restarted until the tank has been drained 6 3 ...

Страница 7: ...cool air coming out in dehumidifying mode No hot air coming out in heating mode Error code E2 appears at bottom of display panel on unit Error code E3 appears at bottom of display panel on unit Error code E4 appears at bottom of display panel on unit POSSIBLE CAUSES Power supply fault 1 Not plugged in 2 Damaged plug or socket 3 Internal fuse blown 1 Timer is set or room temperature is lower than t...

Отзывы: