  5.  CONTROLS

Original Language Version

SAC9000.V2   Issue No.1 19/01/10

Fig.5

Fig.6

5.1 

POWER.

  Press this key to turn the machine ON or OFF. 

 

 

When the machine turns on the default mode is cooling with a low fan speed.

5.2 

MODE. 

Press this key to cycle through the four available modes. COOLING,  

 

 

 

DEHUMIDIFYING, HEATING with fan, and FAN ONLY. 

5.3 

FAN.

  

Once the machine is on, this key selects between high and low fan speed.

5.4 

UP.

  

Under COOLING or HEATING mode press this key to raise the temperature  

 

 

(16 to 31°C).

5.5 

DOWN.

   Under COOLING or HEATING mode press this key to lower the temperature  

 

 

(16 to 31°C). 

5.6 

SLEEP.

  Under COOLING or HEATING mode press this key to turn the sleep function ON or OFF.

5.7 

TIMER.

   Under power ON or standby mode, press this key to set the ON/OFF time based on the 24hr clock.

5.8 

REMOTE CONTROL.

 The remote control functions are the same as those on the main control panel and share  

 

the same indicator symbols.  

Содержание SAC9000.V2

Страница 1: ... 1 1 1 and 1 1 2 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload 1 1 5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the c...

Страница 2: ...DO NOT allow the unit to get wet as this may cause an electric shock and will damage the unit DO NOT let the power lead touch a hot surface lie in a hot airflow or run under a carpet DO NOT insert or allow objects to enter any openings of unit as this may cause an electric shock fire or damage to unit DO NOT use in bathroom shower room or in any environment of excessive condensation DO NOT use the...

Страница 3: ...iency of the unit 4 2 Seal Plate placement See fig 3F Identify a suitable window which can be vertically or horizontally opened Match the window opening to the height of the seal plate Slide the inner part of the seal plate out until it matches the width of the window and lock the two parts together by tightening the screws on the inside edge of the inner slide Permanently screw the seal plate to ...

Страница 4: ... on this key selects between high and low fan speed 5 4 UP Under COOLING or HEATING mode press this key to raise the temperature 16 to 31 C 5 5 DOWN Under COOLING or HEATING mode press this key to lower the temperature 16 to 31 C 5 6 SLEEP Under COOLING or HEATING mode press this key to turn the sleep function ON or OFF 5 7 TIMER Under power ON or standby mode press this key to set the ON OFF time...

Страница 5: ...fan mode is reached indicated by the fan symbol fig 7 8 6 4 3 Press the FAN key to switch between a low or high fan speed 6 5 TIMER MODE In standby mode press TIMER to set the switch ON time the timer symbol lights 6 5 1 Repeatedly press the timer key to advance the time in one hour increments from 1 to 24 hours Stop when you reach the required switch on time 6 5 2 To set the power OFF time the ma...

Страница 6: ...he assembled connector fig 8 4 onto the water outlet and push the drain tube fig 8 5 onto the connector See fig 8 above WARNING Switch off the machine and unplug it from the mains power supply before performing any maintenance or repairs 8 1 CLEANING 8 1 1 Remove the plug from the mains power supply 8 1 2 Use a soft damp cloth to clean the machine outer casing Don t use chemical agents such as ben...

Страница 7: ... from room Filters too dirty Clean or replace filters Air inlets or air outlet is blocked Remove blockage Machine too noisy Machine is not situated on level ground Move to flat and solid ground Compressor not working Compressor heat protection cut out operated Wait for 3 minutes restart the machine when temperature normal Environmental Protection Recycle unwanted materials instead of disposing of ...