Sealey SAC20030B Скачать руководство пользователя страница 2

1.2.    

GENERAL SAFETY 

 

9

   Familiarise yourself with the application and limitations of the compressor.   

 

 

9

   Ensure the compressor is in good order and condition before use. If in any doubt 

DO NOT

 use the unit and contact your Sealey Stockist.

 

‰

   WARNING! 

Item must be serviced by an authorised agent. 

DO NOT

 tamper with or attempt to adjust pressure switch or safety valve.

 

8

   DO NOT 

carry out any welding operations on any pressurised part of the vessel.

 

9

   Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has 

 

9

   been  vented. 

 

9

   Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may be  

  dangerous and will invalidate your warranty.

 

9

   Read the instructions relating to any accessory to be used with this compressor. Ensure the safe working pressure of any air appliance  

 used 

exceeds compressors output pressure. If using a spray gun, check that the area selected for spraying is provided with an air change  

  system/ventilation.

 

9

   Ensure the air supply valve is turned off before disconnecting the air supply hose to move a transportable compressor use the 

 

9

   handle only. Lift the compressor so that the front leg gives enough clearance for manoeuvring but maintain unit’s centre of gravity in front  

  of the wheels. 

DO NOT

 attempt to lift or move the compressor by any other means. 

 

9

   Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

 

9

   Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.

 

9

   Ensure the air hose is not tangled, twisted or pinched.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

  Only move the compressor by the handle (if portable).

 

8

   DO NOT

 dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

 

8

   DO NOT

 use the compressor outdoors, or in damp, or wet, locations.

 

8

   DO NOT

 operate within the vicinity of flammable liquids, gases or solids.

 

8

   DO NOT

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot.

 

8

   DO NOT

 use this product to perform a task for which it has not been designed.

 

8

   DO NOT

 deface the certification plate attached to the compressor tank.

 

8

   DO NOT

 cover the compressor or restrict air flow around the unit whilst operating.

 

   DANGER! DO NOT

 direct the output jet of air towards people or animals.

 

8

   DO NOT

 operate the compressor without an air filter.

 

8

   DO NOT

 allow anyone to operate the compressor unless they have received full instructions.

 

‰

   WARNING! 

The air tank is a pressure vessel and the following safety measures apply:

 

8

  DO NOT

 tamper with the safety valve, 

DO NOT

 modify or alter the tank in any way and 

DO NOT

 strap anything to the tank.

 

8

   DO  NOT

 subject the tank to impact, vibration or to heat and 

DO NOT

 allow contact with abrasives or corrosives.

 

9

   Drain condensation from tank daily and inspect inside walls for corrosion every three months and have a detailed tank inspection carried  

  out annually. The tank shell must not fall below the certified thickness at any point. 

 

‰

   WARNING! 

If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.

  

 

9

   When not in use, store the compressor carefully in a safe, dry, childproof location.

 

9

   When the compressor is not in use, it should be switched off, disconnected from the mains supply and the air drained from the tank. 

 

9

   Under  the 

PRESSURE SYSTEMS SAFETY REGULATIONS 2000

 it is the responsibility of the owner of the compressor to initiate a   

  system of inspection that both defines the frequency of the inspection and appoints a person who has specific responsibility for carrying  

  out the inspection.

2. 

INTRODUCTION

Belt driven pump with aluminium cylinders and cast iron liners for reduced weight and improved resistance to wear. Fitted with a 3hp motor. 

Heavy-duty drive guards protect belt and flywheel that is designed to force air over the pump to aid cooling. Suitable for general purpose workshop 

applications. Precision welded receiver tank manufactured to meet Pressure Vessel Directive.

3. 

SPECIFICATION

4.  ASSEMBLY

4.1.    

Remove compressor from packaging and inspect for shortages

/

damage. If items are missing or damaged contact your supplier.

4.2.    

Save the packing material for future transportation of the compressor. We recommend that you store the packing in a safe location, at  

 

least for the period of the guarantee. Then, if necessary, it will be easier to send the compressor to the service centre.

4.3.   

 

Assemble the fixed wheels / castor wheel / rubber feet to the compressor as required (see fig.1).

Original Language Version

© Jack Sealey Limited

  

Model:

SAC20030B

SAC15030B

  Motor Output (HP):

3

3

  Voltage / Phase:

230/1

230/1

  Input current:

13A

13A

  Speed (rpm):

1000

1000

  Air Displacement (cfm/Lm):

10.8/305

10.8/305

  Outlet:

Quick release coupling Quick release coupling

  Max Free Air Delivery (cfm/Lm):

5.3/150

5.3/150

  Max Pressure (psi/bar):

116/8

116/8

  Tank Capacity (L):

200L

150L

  Dimensions (WxDxH) (mm):

1650 x 520 x 820

1300 x 510 x 815

  Noise (dB(A)):

97

97

SAC20030B, SAC15030B       Issue: 1      08/03/21

Содержание SAC20030B

Страница 1: ...or the safe condition of those appliances and the safety of the appliance operators If in any doubt about electrical safety contact a qualified electrician 1 1 3 Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply See 1 1 1 and use a Portable Appliance Tester 1 1 4 Ensure that cables are always protected against short circuit and overload ...

Страница 2: ...T operate the compressor without an air filter 8 DO NOT allow anyone to operate the compressor unless they have received full instructions WARNING The air tank is a pressure vessel and the following safety measures apply 8 DO NOT tamper with the safety valve DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank 8 DO NOT subject the tank to impact vibration or to heat and...

Страница 3: ...RATION WARNING Ensure that you have read understood and apply Section 1 safety instructions IMPORTANT Use of extension leads to connect these compressors to the mains is not recommended as the resulting voltage drop reduces motor and therefore pump performance and could damage the compressor NOTE Take care when selecting tools for use with the compressor Air tool manufacturers normally express the...

Страница 4: ...r disconnect from electricity supply and release all air from the tank 6 2 Operations to be carried out after the first 50 working hours a Check that all bolts nuts are tight particularly those retaining the crankcase and cylinder head b Replace the lubricating oil fig 4 6 3 Operations to be carried out weekly a Drain condensation by opening the valve located under the tank fig 7 Place a container...

Страница 5: ... and look for bubbles Tighten connections showing leaks If problem persists contact Authorised Service Agent Pressure switch valve leaks when compressor is idle Non return valve seal defective Discharge all tank pressure Referring to fig 4 and fig 9 unscrew valve cap A Clean rubber disc B and its seat Refit all parts accurately Compressor stops and does not restart Power failure Motor failure Chec...

Страница 6: ...rding to local regulations Note It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice Important No Liability is accepted for incorrect use of this product Warranty Guarantee is 12 months from purchase date proof of which is required for any claim WEEE REGULATIONS Dispose of this product at the end of ...

Отзывы: