Replace sight glass and refill through the filler aperture. Do  

 

not  overfill. Replace plug (fig.2A).

 

Recommended oil for compressors, suitable for room  

 

temperatures ranging from +5ºC to +25ºC. SEALEY CPO  

 

or equivalent SAE 40 compressor oil.

 

Room temperature below +5ºC: SAE 20 compressor oil.

 

WARNING! Never mix different oils and do not use 

 

non-detergent/low quality oils as the compressor may be  

 

damaged. Dispose of waste oil only in accordance with  

 

local authority requirements.

6.4.

 

OPERATIONS TO BE CARRIED OUT EVERY 500 hOURS:

 

a)

  Replace air filter.

 

b)

  Check all tube fittings and electrical connections.

 

Inspection of pressure tank both inside and out.

 

Under the PRESSURE SYSTEMS REGULATIONS 2000 it  

 

is the responsibilty of the owner of the compressor to  

 

initiate a system of inspection that both defines the  

 

frequency of the inspection and appoints a person who  

 

has specific responsibilityfor carrying out the inspection.

 

IMPORTANT! Failure to carry out maintenance tasks may  

 

invalidate the warranty on your compressor.

7.  TROUBLESHOOTING  

FAULT

CAUSE

REMEDY

1A)  Pressure drop in the tank

Air leaks at connections

Run  compressor  to  max.  pressure,  switch  off.                   

Brush soap solution over connections and look for 

bubbles. Tighten connections showing leaks, 

If problem persists contact Authorised Service Agent

1B)  Pressure drop in the tank

Air leaks from safety valve

Operate the safety valve manually by pulling on the 

ring. If valve continues to leak when in the closed 

position it should be replaced

1C)  Pressure drop in the tank

Air leaks from cylinder head gasket

Check tightness of head bolts. If leak continues 

contact authorised service agent

2)  Pressure switch valve leaks when 

    compressor is idle

Non-return valve seal defective

Empty the air tank. Referring to fig.6, remove the 

non-return valve cap (3), spring (2) and seal (1). 

Clean the seal and its seat, or if necessary replace 

the seal

3)  Air leaks from tank body or tank welds

Internal corrosion caused by infrequent tank 

draining or non permitted modifications to tank

Tank could rupture or explode. Cannot be repaired 

DISCONTINUE USE IMMEDIATELY

4A)  Motor stops and will not restart

Thermal cut out has operated

Allow unit to cool for 30 minutes before restarting

4B)  Motor stops and will not restart

Supply fuse has tripped

Reset fuse and restart unit. If repeated tripping 

occurs replace the check valve or contact 

authorised service agent

5)  Compressor stops and does not restart

Motor failure

Contact Authorised Service Agent

6A)   Compressor does not stop at max. pressure

Pressure switch fault

Contact Authorised Service Agent

6B)   Compressor does not stop at max. pressure

Filter clogged

head gasket or valve fault

Replace filter element.

Contact Authorised Service Agent

7)  Compressor noisy with metallic knock

Bearing or piston damage

Contact Authorised Service Agent

8)  Excessive moisture in discharged air

high humidity environment

Drain tank after each use

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

W e b

email

fig.6  

IMPORTANT WARNING

 - Air contaminants taken into the compressor will affect optimum performance. Example: Body filler dust or paint 

overspray will clog the pump intake filter and may cause internal damage to pump/motor components. Please note that any parts damaged by 

any type of contamination will not be covered by warranty.

Original Language Version

SAC0610E.V2    Issue No: 1 - 02/12/13

© Jack Sealey Limited

 

  

Environmental Protection.

  

Recycle unwanted materials instead of disposing of them as  

   

waste. All tools, accessories and packaging should be sorted,  

   

taken to a recycle centre and disposed of in a manner which  

   

is compatible with the environment.

  

WEEE Regulations.

  

Dispose of this product at the end of its working life in compliance   

   

with the EU Directive on Waste Electrical and Electronic Equipment.  

   

When the product is no longer required, it must be disposed of in an  

   

environmentally protective way. Contact your local solid waste  

 

   

authority for recycling information.

Parts support is available for this product. To obtain a parts listing and/or diagram, 

please log on to www.sealey.co.uk, email [email protected] or telephone 01284 757500.

Содержание SAC0610E.V2

Страница 1: ... Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse see fuse rating at right 1 1 7 DO NOT pull or carry the appliance by the power cable 1 1 8 DO NOT pull the plug from the socket by the cable 1 1 9 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a quali...

Страница 2: ...nstructions relating to any accessory to be used with this compressor Ensure the safe working pressure of any air appliance used exceeds compressors output pressure If using a spray gun check that the area selected for spraying is provided with an air change ventilation system 3 Ensure the air supply valve is turned off before disconnecting the air supply hose 3 To move the compressor use the hand...

Страница 3: ... cutting in and out as required to restore the air pressure in the tank The pressure switch fig 5 8 stops the motor when the maximum tank pressure is reached and restarts it when pressure falls below the minimum threshold approx 2 bar 29psi less than the maximum pressure Note a If the motor does not cut in and out but runs continuously when using an air appliance the capacity of the compressor may...

Страница 4: ...ply fuse has tripped Reset fuse and restart unit If repeated tripping occurs replace the check valve or contact authorised service agent 5 Compressor stops and does not restart Motor failure Contact Authorised Service Agent 6A Compressor does not stop at max pressure Pressure switch fault Contact Authorised Service Agent 6B Compressor does not stop at max pressure Filter clogged Head gasket or val...

Страница 5: ...e 2005 88 EC Outdoor Noise Emissions Directive 2006 95 EC Low Voltage Directive 2002 96 EC WEEE Directive 2004 108 EC EMC Directive 2011 65 EU RoHS Directive 93 68 EEC CE Marking Directive 97 23 EC Pressure Equipment Directive And the following harmonised standard s Technical file compiled by Jack Sealey Ltd Signed Date Place Bury St Edmunds Name Position Being the responsible person appointed by ...

Отзывы: