background image

01284 757500

01284 703534

E-mail:

[email protected]

NOTE: 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this equipment.

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION:

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor,
Sealey Group,

Bury St. Edmunds, Suffolk.

Declaration of Conformity  

We, the sole UK importer, declare that the products listed below are in conformity with the following

standards and directives.

The construction files for these products are held by the

Manufacturer and may be inspected, by a national  authority,

upon request to Jack Sealey Ltd.

For Jack Sealey Ltd. Sole UK importer of Sealey Power Products.

DIRECT DRIVE COMPRESSORS 

Models: SA9925/2, SA9925/2.5 &

SA9950/2.5

87/404/EEC Pressure Vessel Directive 

89/336/EEC EMC Directive 

73/23/EEC LV Directive

98/37/EC Machinery Directive

Signed by Mark Sweetman

8th June 2001

SA9925/2 & /2.5 & SA9950/2.5 - 1069 - (1) - 070601

b) Check all tube fittings and electrical connections.

c) Inspect pressure tank inside and out for damage or corrosion.

5.6. 

Scheduled maintenance table

5.7.

Recommended oils

Recommended oil for compressors, suitable for room 

temperatures ranging from +5

O

C to +25

O

C.

SEALEY CPO or equivalent SAE 40 compressor oil.

Room temperature below +5

O

C: SAE 20 compressor oil.

Approximate oil capacity: 0.16 litres.

fig. 5

6. TROUBLE SHOOTING  

•

•

Internal & external

inspection of tank

•

General cleaning of

compressor

Check tube fittings and

electrical connections

•

•

Check for oil leaks

Replace air filter

•

Clean intake filter

•

•

•

Check oil level

•

Drain condensation

500 hrs.

200 hrs.

100 hrs.

Daily

Maintenance

Operations

Replace oil

Check cut-out

Fault

Cause

Remedy

Pressure drop in the tank

Air leaks at connections

Run compressor to max. pressure, switch off.

Brush soap solution over connections and look for

bubbles. Tighten connections showing leaks. 

If problem persists contact Authorised Service Agent.

Pressure switch valve leaks when compressor is idle

Non-return valve seal defective

Empty the air tank, remove the non-return valve cap

‘E’ (fig.5) and clean, or if necessary replace, 

the seal ‘D’. 

Compressor stops and does not restart

Motor failure

Contact Authorised Service Agent.

Compressor does not stop at max. pressure

Pressure switch fault

Contact Authorised Service Agent.

Compressor does not stop at max. pressure

Filter clogged

Head gasket or valve fault

Replace filter element.

Contact Authorised Service Agent.

Compressor noisy with metallic knock

Bearing or piston damage

Contact Authorised Service Agent.

Содержание SA9925/2

Страница 1: ... is available We recommend you discuss the installation of a industrial round pin plug socket with your electrician 1 1 11 Cable extension reels When a cable extension reel is used it should be fully unwound before connection A cable reel with an RCD fitted is recommended since any product which is plugged into the cable reel will be protected The section of the cores in the cable is important and...

Страница 2: ...put hp Voltage Phase Current A Pump Type Pump Speed rpm Piston Displacement cfm At 2 5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level dB A SA9925 2 2 230 1 8 5 D10 R 2850 8 7 7 3 7 7 6 3 25 116 8 82 SA9925 2 5 2 5 230 1 9 5 D11 R 2850 9 5 8 1 8 4 7 0 25 116 8 82 SA9950 2 5 2 5 230 1 9 5 D11 R 2850 9 5 8 4 8 1 7 0 50 116 8 82 2 1 Specifications Note 2 5 bar is recommended press...

Страница 3: ...he compressor air out which varies according to the pressure setting Do not confuse this with the compressor displacement which is the air taken in by the compressor air in Air out is always less than air in due to losses within the compressor and so it is important that before choosing equipment you study the Free Air Delivery figures shown in the Specification chart section 2 p WARNING Ensure th...

Страница 4: ... out for damage or corrosion 5 6 Scheduled maintenance table 5 7 Recommended oils Recommended oil for compressors suitable for room temperatures ranging from 5O C to 25O C SEALEY CPO or equivalent SAE 40 compressor oil Room temperature below 5O C SAE 20 compressor oil Approximate oil capacity 0 16 litres fig 5 6 TROUBLE SHOOTING Internal external inspection of tank General cleaning of compressor C...

Отзывы: