2. 

INTRODUCTION & SPECIFICATION

3.1.  Assembly

3.1.1.  Fit suction cover (item 52 in parts list) over drive housing (item 30) and retain with clamp (item 53).

3.1.2.  Attach plate (item 58) on hose to end of sander handle using washer and nipple (items 60 & 61) supplied.

3.1.3.  Connect suction outlet (item 59) to dust extraction system.

3.2.  Air Supply

3.2.1.  Ensure the sander air valve (or throttle) is in the "Off" position before connecting to the air supply.

3.2.2.  You will require an air pressure between 70-90psi, and an air flow according to the specification above.

3.2.3. 

p

 

WARNING! 

Ensure the air supply is clean and does not exceed 90 psi while operating the sander. 

 

Too high an air pressure and/or unclean air will shorten the product life due to excessive wear, and may  

 

be dangerous causing damage and/or personal injury. 

3.2.4.  Drain the air tank daily. Water in the air line will damage the sander 

and will invalidate your warranty.

 

3.2.5.  Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig 1.

3.2.6.  Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). 

 

The minimum hose diameter should be 1/4” I.D. and fittings must have the same inside dimensions. 

3.2.7.  Keep hose away from heat, oil and sharp edges. Check hoses for wear and make certain that all

 

connections are secure. 

3.3.  Couplings

 

Vibration may cause failure if a quick change coupling is connected directly to the

 

air sander. To overcome this, connect a leader hose to the sander. A quick change

 

coupling may then be used to connect the leader hose to the air line recoil hose. 

 

See figs 1 & 2. 

3. 

PREPARING SANDER FOR USE

1.2.  

LEAD PAINT WARNING! 

Paint once contained lead as a traditional ingredient. The dust caused by the removal of such paint is 

toxic and must therefore be avoided. The following action must be taken before using the sander on 

a surface that you suspect may contain lead paint.

 1. 

User must determine potential hazard relating to age of paint to be removed (modern paints do  

 

not have lead content). 

 2. 

DANGER! 

Keep all persons and pets away from the working area. The following persons are

 

particularly vulnerable to the effects of lead paint dust: 

Expectant women, babies and children. 

 3. 

We recommend personal protection by using the following safety items:

 

a

)  Paint Spray Respirator (Our ref SSP16EN)   

 

b

)  PE Coated Hooded Coverall (Our ref SSP266). 

c

)  Latex Gloves (Our ref SSP24).

 4. 

Take adequate measures to contain the paint dust, flakes and scrapings.

 5. 

Continue to wear safety equipment as in (3) above and thoroughly clean all areas when task is

 

complete. Ensure paint waste is disposed of in sealed bags or containers.

fig 1

Pad Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150mm

Thread Size  . . . . . . . . . . . . . . . . . . . . . . . . . 5/16” UNF

Free Speed  . . . . . . . . . . . . . . . . . . . . . . . . . 10000rpm

Operating Pressure  . . . . . . . . . . . . . . . . . . . . . . . 90psi 

Air Consumption  . . . . . . . . . . . . . . . . . . . . . . . 10.6cfm

Air Inlet   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Extraction Outlet  . . . . . . . . . . . . . . . . . . . . . . . Ø28mm 

Sound   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93.3dB(A)

 

92.8dB(C)

Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . <2.5m/s

2

Weight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2kg

The SA7/SAS has a light weight aluminium body with a smooth double bearing counter balance assembly for 

fatigue-free operation and an air diversion system to maximize dust extraction.

fig 2

Original Language Version

SA7/SAS    Issue: 3 - 

28/10/09

Отзывы: