5.  mAiNTeNANce  

 

in order to keep the compressor in good working condition, periodic maintenance is essential.

  

imporTANT! Failure to carry out maintenance tasks may invalidate the warranty on your 

 

compressor.

 

wArNiNG! before performing any maintenance operation, switch off compressor, disconnect 

 

from power supply and vent air from tank. remove front and rear panels to provide access  

 

 

and light.

5.1   operATioNs To be cArrieD oUT AFTer THe FirsT 5 worKiNG HoUrs:

5.1.1  check that all nuts/bolts are tight, particularly those retaining the crankcase and cylinder heads.

5.2   operations to be carried out after the first 100 working hours:

5.2.1  replace the lubricating oil (see 5.9. below).

5.3  operATioNs To be cArrieD oUT DAiLY:

 

5.3.1  regularly clean dirt and dust away from the safety devices with a clean cloth or blowing with low pressure   . .  

 

 

 

 

compressed air. Generally keep the compressor clean. 

5.4  operATioNs To be cArrieD oUT weeKLY:

5.4.1

 

Drain condensation by opening the valve located under the tank of sAc89024VLn (fig.7) or the bottom of the front panel on   

 

 

sAc82425VLn (fig.6G). Place a container under the valve to collect any condensation, as it may contain residual oil.

 

close valve after draining condensation and dispose of it safely.

5.5  operATioNs To be cArrieD oUT moNTHLY: sAc89025vLN

 

(or more frequently, if the compressor operates in a very dusty atmosphere)

5.5.1

 

clean the air filters. turn off the compressor and using stored air from it's tank, clean the filters with compressed air. the top cover  

 

 

of sAc89025VLn needs to be removed. remove the air filter assembly by removing the single phillips screw.  

  

imporTANT! 

Wear eye protection and 

Do NoT

 direct air towards the body or hands. 

Do NoT

 operate the compressor without the    

 

filters as foreign bodies or dust could seriously damage the pump. replace the filter elements.

5.6   operATioNs To be cArrieD oUT everY 50 HoUrs: sAc82425vLN

 

(or more frequently, if the compressor operates in a very dusty atmosphere)

5.6.1

 

clean the air filters. turn off the compressor and using stored air from it's tank, clean the filters with compressed air. Both side  

 

 

panels of sAc89025VLn need to be removed. remove the air filter assembly by removing the single phillips screw.  

  

imporTANT! 

Wear eye protection and 

Do NoT

 direct air towards the body or hands. 

Do NoT

 operate the compressor without the    

 

filters as foreign bodies or dust could seriously damage the pump. replace the filter elements. 

5.7   operATioNs To be cArrieD oUT everY 100 HoUrs: 

5.7.1  check oil level, top up if necessary, one of the side panels on sAc89025VLn will need to be removed to check the oil level.

5.7.2  check for oil leaks.

5.8   operATioNs To be cArrieD oUT everY 200 HoUrs: 

5.8.1  check the automatic cut-out at maximum pressure, and the automatic cut-in at 2 bar below maximum pressure.

5.8.2

 

replace air filters (see 5.5 / 5.6).

5.9   operATioNs To be cArrieD oUT everY 500 HoUrs:

5.9.1  replace the lubricating oil.

 

remove the oil breather plug/dipstick then remove oil drain bolt (fig.8), draining oil into a suitable container. Drain when the    

 

 

compressor is hot if possible, so that the oil drains rapidly and completely. 

NoTe! 

for 

sAc89025vLN 

its recommended to use a suction oil drainer, due to the design of the compressor, space around the drain plug is  

 

minimal. incline compressor to ensure complete drainage. replace oil drain bolt and refill with fresh oil through the oil filler/breather    

 

aperture (fig.8). 

Do NoT

 overfill. replace oil breather plug/dipstick.

 

recommended oils:

 

synthetic oil suitable for temperatures ranging from -5°c to 45°c: viscosity 5W50. We do not recommend using mineral oil in these    

 

compressors.

 

Part no.  Qty.          Description

 

fso1 

1ltr x 12    compressor oil fully synthetic

 

fso1s  1ltr x 1      compressor oil fully synthetic

 

fso5 

5ltr x 1      compressor oil fully synthetic

 

wArNiNG! Dispose of waste oil only in accordance with local authority requirements.

5.10.

 

imporTANT wArNiNG

 - Air contaminants taken into the compressor will affect optimum performance. Example: Body filler dust or paint  

 

overspray will clog the pump intake filter and may cause internal damage to pump/motor components. Please note that any parts  

 

 

damaged by any type of contamination will not be covered by warranty.

fig.7

fig.8

Original Language Version

sAc89025VLn, sAc82425VLn    issue: 2 - 22/02/12

A

b

fig. 9

Содержание Power PRODUCTS SAC89025VLN

Страница 1: ...ead 1 1 8 DO NOT pull power plugs from sockets by the power cable 1 1 9 DO NOT use worn or damage leads plugs or connections Immediately replace or have repaired by a qualified electrician 1 1 10 A U K 3 pin plug with ASTA BS approval is fitted In case of damage cut off and fit a new plug according to the following instructions UK only see diagram at right Discard old plug safely Ensure the unit i...

Страница 2: ...tempt to move the compressor by pulling the air tool hose 7 DO NOT use this product to perform a task for which it has not been designed 7 DO NOT operate the compressor with any of the panels removed 7 DO NOT deface the certification plate attached to the end of the compressor tank 7 DO NOT cover compressor or restrict air flow around the machine whilst operating DANGER DO NOT direct the output je...

Страница 3: ...the compressor and leave the compressor running with the regulator tap fig 4C fig 5D set to maximum pressure Make sure that the pressure in the tank rises and that the compressor stops automatically when the maximum pressure value allowed written on the specification plate and shown on the gauge fig 4G fig 5C is achieved The compressor will now operate automatically The pressure switch stops the m...

Страница 4: ...t s tank clean the filters with compressed air Both side panels of SAC89025VLN need to be removed Remove the air filter assembly by removing the single phillips screw IMPORTANT Wear eye protection and DO NOT direct air towards the body or hands DO NOT operate the compressor without the filters as foreign bodies or dust could seriously damage the pump Replace the filter elements 5 7 Operations to b...

Страница 5: ...h off Brush soap solution over connections and look for bubbles Tighten connections showing leaks If problem persists contact Authorised Service Agent Pressure switch valve leaks when compressor is idle Non return valve seal defective Empty the air tank remove the non return valve cap A fig 9 and clean If necessary replace the seal B Compressor stops and does not restart Overload cut out operated ...