PC200SD110V.V2 Issue No.2 22/10/09
Original Language Version
9. cONSUmABLeS
locking Cartridge filter (must be used for dry vacuuming). . . . . . . . . . model No. PC200Cfl
foam filter (Pack of 10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . model No. PC200ff10
PC200SD Dust Bags (Pack of 5) optional extra . . . . . . . . . . . . . . . . . . model No. PC200PB5
ImpORTANT! IF THe mAcHINe IS USeD WITHOUT A cARTRIDGe FILTeR FITTeD THe mOTOR WILL eveNTUALLY BURN
OUT AND YOUR GUARANTee WILL Be INvALIDATeD. ALWAYS Keep A SpARe cARTRIDGe FILTeR HANDY.
7. mAINTeNANce
7.1
GeNerAl mAINteNANCe.
7.1.1 ensure the machine is unplugged from the power
supply.
7.1.2 Disconnect the hose from the container.
7.1.3 undo the clasps and remove power head from the
container.
7.1.4 Clear out any dirt or debris from the container and hose.
7.1.5 Clean the foam filter by washing it in a mild soapy
solution.
7.1.6 Check that the telescopic suction tube operates
smoothly and check the power cable to make sure it has
not received any damage.
7.2
cARTRIDGe FILTeR mAINTeNANce.
7.2.1 Handle the filter carefully when cleaning or installing.
7.2.2 Carefully remove the cartridge filter (fig.6.1) and
inspect it for damage. A filter that has small holes or
tears in it will not perform efficiently and should be
replaced.
7.2.3 to clean a dry filter, tap it inside a waste bin. (fig.6.2)
7.2.4 Do not use the filter if it becomes wet as the filter will
clog quickly and be very difficult to clean. (the cartridge
filter is designed for dry vacuuming only).
Should the filter be inadvertently wetted it should be
rinsed from the inside (fig.6.2) and allowed to air dry for
24 hours.
7.2.5 fit a new/cleaned filter and with the raised rim
uppermost fit the cartridge filter tube down over the filter
basket and push fully home. Place the locking disc onto
the top of the filter and turn the locking bar until the latch
drops into the slot in the top of the filter basket.
Continue turning until the filter is fully locked down.
(fig.6.4).
8.TROUBLeSHOOTING
ProBlem
CAuSe
SolutIoN
1) Cleaner will not operate
1a) No power supply
Check supply
1b) faulty power cable, switch or motor
Check and repair or replace faulty item
1c) Container full of liquid
empty container
2) Dust comes from the motor cover
2) Cartridge filter missing or damaged
Fit or replace cartridge filter
3) Reduced efficiency and increased
motor speed/vibration
3a) Dust container full
empty container
3b) filter clogged
Clean or replace cartridge filter
3c) Nozzle, hose or container inlet blocked
Check nozzle, hose & container inlet for blockage
fig.6
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
ImpORTANT:
No liability is accepted for incorrect use of this product.
WARRANTY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORmATION:
for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park
,
Bury St. edmunds, Suffolk,
IP32 7Ar
www.sealey.co.uk
Web