background image

PC200SD110V.V2   Issue No.2   22/10/09

Original Language Version

  9.   cONSUmABLeS

locking Cartridge filter (must be used for dry vacuuming). . . . . . . . . . model No. PC200Cfl

 foam filter (Pack of 10) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . model No. PC200ff10

PC200SD Dust Bags (Pack of 5) optional extra . . . . . . . . . . . . . . . . . . model No. PC200PB5

ImpORTANT! IF THe mAcHINe IS USeD WITHOUT A cARTRIDGe FILTeR FITTeD THe mOTOR WILL eveNTUALLY BURN 

OUT AND YOUR GUARANTee WILL Be INvALIDATeD. ALWAYS Keep A SpARe cARTRIDGe FILTeR HANDY.

  7.  mAINTeNANce

7.1 

GeNerAl mAINteNANCe.

7.1.1  ensure the machine is unplugged from the power  

 

 

supply.

7.1.2  Disconnect the hose from the container.

7.1.3  undo the clasps and remove power head from the  

 

 

container.

7.1.4  Clear out any dirt or debris from the container and hose.

7.1.5  Clean the foam filter by washing it in a mild soapy  

 

 

solution.

7.1.6  Check that the telescopic suction tube operates  

 

 

smoothly and check the power cable to make sure it has  

 

not received any damage.

7.2 

cARTRIDGe FILTeR mAINTeNANce.

 

7.2.1  Handle the filter carefully when cleaning or installing. 

7.2.2  Carefully remove the cartridge filter (fig.6.1) and  

 

 

inspect it for damage. A filter that has small holes or    

 

tears in it will not perform efficiently and should be  

 

 

replaced.

7.2.3  to clean a dry filter, tap it inside a waste bin. (fig.6.2) 

7.2.4  Do not use the filter if it becomes wet as the filter will    

 

clog quickly and be very difficult to clean. (the cartridge  

 

filter is designed for dry vacuuming only).  

 

 

 

Should the filter be inadvertently wetted it should be    

 

rinsed from the inside (fig.6.2) and allowed to air dry for  

 

24 hours.

7.2.5  fit a new/cleaned filter and with the raised rim  

 

 

uppermost fit the cartridge filter tube down over the filter  

 

basket and push fully home. Place the locking disc onto  

 

the top of the filter and turn the locking bar until the latch  

 

drops into the slot in the top of the filter basket.  

 

 

Continue turning until the filter is fully locked down.  

 

 

(fig.6.4). 

 

 

 

8.TROUBLeSHOOTING

ProBlem

CAuSe

SolutIoN

1) Cleaner will not operate

1a) No power supply

Check supply

1b) faulty power cable, switch or motor

Check and repair or replace faulty item

1c) Container full of liquid

empty container

2) Dust comes from the motor cover

2)   Cartridge filter missing or damaged

Fit or replace cartridge filter

3) Reduced efficiency and increased 

motor speed/vibration

3a) Dust container full

empty container

3b) filter clogged

Clean or replace cartridge filter

3c) Nozzle, hose or container inlet blocked

Check nozzle, hose & container inlet for blockage

fig.6

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

ImpORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORmATION:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. edmunds, Suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Содержание PC200SD110V.V2

Страница 1: ... or generator is of an adequate rating for the cleaner 1 1 8 DO NOT pull or carry the appliance by its power supply lead 1 1 9 DO NOT pull the plug from the socket by the power cable 1 1 10 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician Ensure the unit is correctly earthed via a three pin 110V plug a Connect th...

Страница 2: ...ed 1 and 2 Insert the wheel assembly mouldings into the two remaining slots in the base ensuring that the number on each moulding matches the number to be found on the base Ensure they are pushed all the way in and fix them with the self tapping screws provided fig 2 4b Do not overtighten 3 6 For dry vacuum cleaning use the locking cartridge filter supplied and push it fully down onto the filter b...

Страница 3: ...again WARNING Not designed for liquid storage Always empty liquids after use and before storing WARNING Ensure you read understand and apply Section 1 Safety Instructions Reminder DO NOT vacuum hazardous substances Use of an incorrect cartridge filter will invalidate your warranty 4 1 Ensure the machine is unplugged from the power supply fig 3 1 4 2 Remove the power head and with the raised rim up...

Страница 4: ...etted it should be rinsed from the inside fig 6 2 and allowed to air dry for 24 hours 7 2 5 Fit a new cleaned filter and with the raised rim uppermost fit the cartridge filter tube down over the filter basket and push fully home Place the locking disc onto the top of the filter and turn the locking bar until the latch drops into the slot in the top of the filter basket Continue turning until the f...

Отзывы: