Sealey ML18/36.V3 Скачать руководство пользователя страница 3

  

4. 

mAINTENANCE

  

WARNING! 

Before replacing the fluorescent tubes or performing any maintenance the unit must be  

 

unplugged from the mains. Allow the tubes to cool before touching them.

  

WARNING! DO NOT

 turn the unit on with the transparent cover removed or with the tubes removed.

4.1.  CHANGING THE FLUORESCENT TUBES.

4.1.1.  Replacement tubes must be the same type and rating as the original tubes supplied. Use Sealey   

 

replacement tubes (Part No: ML18/36.V3-B).

4.1.2. Remove the transparent cover by removing the two cover screws and lifting it away.

4.1.3. Each tube can be removed by rotating it in either direction until one of the connector pins appears at the  

 

top of the tube holder slot. Lift out the old tube and replace it with a new one. Push the new tube all the  

 

way into the tube holder slots at both ends and then rotate the tube a quarter of a turn in either direction.

4.1.4. Ensure that the tubes are correctly installed and seated before switching on.

4.2.  CLEANING.

4.2.1.  Clean the unit with a damp cloth and a mild soapy solution. Do not use solvents or abrasive cleaners.

Tubes: 

2 x 20W 

 

Tube Length: 

590mm 

 

Mains Supply: 

230V 50Hz 40mA 

 

Battery: 

6V 4.5Ah 

 

Operating Time:  1 Tube:  

3hrs  

 

                         2 Tubes:  

1hr 30min 

 

Replacement Tube: 

ML18/36.V3-B 

 

Original Language Version

ML18/36.V3    Issue: 1 

- 27/07/11

Содержание ML18/36.V3

Страница 1: ...ug with ASTA BS approval is fitted In case of damage cut off and fit a new plug according to the following instructions discard old plug safely UK only see diagram to the right Ensure the unit is correctly earthed via a three pin plug a Connect the green yellow earth wire to the earth terminal E b Connect the brown live wire to live terminal L c Connect the blue neutral wire to the neutral termina...

Страница 2: ... the event of mains power failure Lantern includes carry handle and floor stand or can also be wall mounted 3 1 CHARGING THE UNIT 3 1 1 The unit will charge when plugged into mains supply regardless of function switch position To achieve fastest charge put function switch to the OFF position 3 1 2 Open the power cable compartment at the back of the lantern Uncoil the power cable and plug it into t...

Страница 3: ...the transparent cover by removing the two cover screws and lifting it away 4 1 3 Each tube can be removed by rotating it in either direction until one of the connector pins appears at the top of the tube holder slot Lift out the old tube and replace it with a new one Push the new tube all the way into the tube holder slots at both ends and then rotate the tube a quarter of a turn in either directi...

Страница 4: ...product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Battery Removal NOTE The lantern battery is a sealed lead acid type By law it must be removed and recycled or disposed of properly according to national and or local regulations Place the lantern front side down Remove the screws from the rear...

Отзывы: