WArninG! – risk of Hand Arm Vibration injury.

this tool may cause Hand Arm Vibration Syndrome if its use is not adequately managed.

This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC .

This tool is to be operated in accordance with these instructions .

this tool has been tested in accordance with: 

EN ISO 28927-5:2009 & BS EN ISO 15744:2008 .

Declaration and verification of Vibration Emission figures are in accordance with EN 12096:1997

Measured vibration emission value (a):  

0.89 m/s²

uncertainty value(k): 

1.5 m/s²

Please note that the application of the tool to a sole specialist task may produce a different average vibration 

emission. We recommend that a specific evaluation of the vibration emission is conducted prior to commencing 

with a specialist task.

A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable 

duration of use for each tool . 

nB: 

Stated Vibration Emission values are type-test values and are intended to be typical . 

Whilst in use, the actual value will vary considerably from and depend on many factors .  

Such factors include; the operator, the task and the inserted tool or consumable . 

nB:

 ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce 

vibration .

The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase 

the risk of Hand Arm Vibration Syndrome.

Health surveillance.

We recommend a programme of health surveillance to detect early symptoms of vibration injury so that 

management procedures can be modified accordingly .

Personal protective equipment.

We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury 

that may result from the uncontrolled use of this tool . We recommend a sufficient supply of clothing (including 

gloves) to enable the operator to remain warm and dry and maintain good blood circulation in fingers etc . Please 

note that the most effective protection is prevention, please refer to the Correct Use and Maintenance section in 

these instructions . Guidance relating to the management of hand arm vibration can be found on the HSC 

website www .hse .gov .uk - Hand-Arm Vibration at Work .

Original Language Version

GSA232    Issue: 1 - 03/06/13

© Jack Sealey Limited 2013

 

Содержание GSA232

Страница 1: ...ck and drill bit 3 Keep drill bits clean and sharp for best and safest performance 3 Maintain correct balance and footing Ensure the floor is not slippery and wear non slip shoes 3 Secure non stable work piece with a clamp vice or other adequate holding device 3 Ensure the chuck is securely fastened to the spindle and the drill bit is secure in the chuck 3 Keep children and unauthorised persons aw...

Страница 2: ...n the off position before connecting to the air supply 3 1 2 You will require an air pressure of 90psi and an air flow according to specification 3 1 3 Drain the air tank daily Water in the air line will damage the drill 3 1 4 Clean air inlet filter weekly Recommended hook up procedure is shown in fig 1 3 1 5 Line pressure should be increased to compensate for unusually long air hoses over 8 metre...

Страница 3: ...oil dripped into the air inlet to prolong its life 5 2 Clean the drill after use 5 3 Loss of power or erratic action may be due to the following a Excessive drain on the air line Moisture or restriction in the air pipe Incorrect size or type of hose connectors To remedy check the air supply and follow instructions in Section 3 b Grit or gum deposits in the drill may also reduce performance If your...

Страница 4: ...ably from and depend on many factors Such factors include the operator the task and the inserted tool or consumable NB ensure that the length of leader hoses is sufficient to allow unrestricted use as this also helps to reduce vibration The state of maintenance of the tool itself is also an important factor a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome Health ...

Отзывы: