background image

instructions for

Drill stanD with cast iron base 500mm 
& 65mm vice 

model no: 

Ds01

thank you for purchasing a sealey product. manufactured to a high standard, this product will, if used according to these 
instructions, and properly maintained, give you years of trouble free performance.

1.  safety  

 

9

only use on firm, level, unobstructed surfaces which are capable of 

            supporting the stand and drill.

 

9

ensure stand is fixed to surface capable of supporting stand, drill 

            and work piece.

 

9

replace or repair damaged parts. use only recommended parts. 

            unauthorised parts may be dangerous and will invalidate the warranty.

 

‰

warninG!

 failure to comply with these instructions may result in damage

           to the stand or other property and/or personal injury. 

 

‰

warninG! 

the warnings, cautions and instructions discussed in this 

            instruction manual cannot cover all possible conditions and situations 
           that may occur. it must be understood that common sense and caution are 
           factors which cannot be built into this product, but must be applied by the operator. 

2.  introDuction

drill stand with cast iron base for vertical drilling using a hand drill. supplied with drill vice which mounts onto the base to secure the workpiece. 
features a preset depth control and stop for drilling depths of up to 60mm, ideal for accurate and repetitive drilling. for use with hand drills 
with a collar diameter of 38mm if used with the adaptor bush or 43mm if used without. drill vice features a quick jaw release feature to allow 
fast and easy adjustment to suit the workpiece.

3.  specification

model no ....................................................................... ds01
collar centre to column ............................................. 150mm
maximum distance collar to base .............................. 345mm
column diameter ......................................................... 25mm
Base size ............................................................155x220mm
collar diameter .................. 43mm (38mm with adapter bush)
overall Height ............................................................ 500mm
Vice Jaw Width ............................................................. 65mm
Vice Jaw depth ............................................................ 25mm
Vice Jaw opening ........................................................ 70mm

4.  assembly

4.1.    

slide the column into the base, making sure that it is level 

 

with the bottom of the base. clamp in place with bolt.

4.2.    

slide the lower collar onto column and position half way.

 

Use Hex key to lock in place. (fig.2.)

ds01 | issue 1 22/01/18

Original Language Version

© Jack sealey limited

      refer to
   instructions

   fig.1

   fig.2

 Wear eye

protection

 Wear protective

gloves

Отзывы: