background image

Original Language Version

© Jack Sealey Limited

CP20VPHT   Issue 1   22/10/21

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

WARNING! – Risk of Hand Arm Vibration Injury.

This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.

This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC.

This tool is to be operated in accordance with these instructions.

Measured vibration emission value (a):  1.843m/s²

Uncertainty value (k):  1.5m/s²

Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a

specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.

A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool.

NB: Stated Vibration Emission values are type-test values and are intended to be typical.

Whilst in use, the actual value will vary considerably from and depend on many factors.

Such factors include; the operator, the task or consumable.

The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration 

Syndrome.

Health surveillance.

We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified 

accordingly.

Personal protective equipment.

We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the

uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and 

maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and 

Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSE website

www.hse.gov.uk - Hand-Arm Vibration at Work.

Содержание CP20VPHT

Страница 1: ...erforming maintenance carrying out adjustments inspecting the machine after striking an object before clearing a blockage before leaving the tool unattended before moving to the next job location 9 WARNING Risk assess the work area Keep bystanders away from the work area DO NOT operate with anyone or pets nearby Check intended work area for wildlife 8 DO NOT use in bad weather conditions especiall...

Страница 2: ...r is fitted with a head that can be adjusted through 6 different positions to a total of 112 5 5 1 2 To adjust the position unlock the head by pressing both of the two large adjustment buttons either side of the cutter head fig 5 5 1 3 Rotate the head to the desired position and then release the buttons to lock the head in place 5 2 SHOULDER HARNESS 5 2 1 Securely fasten the buckle fig 6 and hook ...

Страница 3: ...ARNING The carbon brushes should not be replaced by anyone but a qualified electrician 7 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Motor does not run Battery is not installed Install the battery Battery problem low charge Recharge the battery If recharging is not effective replace battery The drive system does not work correctly Ask your local authorized Sealey service center for repair Motor stops r...

Страница 4: ...2 EC This tool is to be operated in accordance with these instructions Measured vibration emission value a 1 843m s Uncertainty value k 1 5m s Please note that the application of the tool to a sole specialist task may produce a different average vibration emission We recommend that a specific evaluation of the vibration emission is conducted prior to commencing with a specialist task A health and ...